Influence of Implantation Technique on Rotational Stability of a Frosted-Haptic Toric Intraocular Lens: A Prospective Contralateral-Eye Study

12. srpna 2026 aktualizováno: Menna Kamel, Ain Shams University

This prospective, randomized contralateral-eye study evaluates whether the implantation technique influences the rotational stability and refractive outcomes of the TECNIS Eyhance™ Toric II intraocular lens (IOL) during cataract surgery. Although balanced salt solution (BSS) hydroimplantation has been proposed to reduce postoperative IOL rotation by eliminating retained ophthalmic viscosurgical device (OVD), the effect of implantation technique on the rotational stability of modern frosted-haptic toric IOLs remains uncertain.

Patients undergoing bilateral cataract surgery with regular corneal astigmatism receive TECNIS Eyhance™ Toric II IOLs in both eyes. One eye is randomized to OVD-assisted implantation and the fellow eye to BSS-assisted hydroimplantation. The primary outcome is postoperative rotational stability assessed using OPD-Scan III at postoperative day 1, week 1, and month 1. Secondary outcomes include postoperative refractive astigmatism, astigmatic prediction error, and visual acuity. The study aims to determine whether implantation technique influences postoperative rotational stability or refractive performance when using a contemporary frosted-haptic toric IOL.

Přehled studie

Postavení

Aktivní, ne nábor

Podmínky

Intervence / Léčba

Typ studie

Intervenční

Zápis (Aktuální)

80

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

    • Dr.
      • Cairo, Dr., Egypt, 11765
        • AinShams university

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dítě
  • Dospělý
  • Starší dospělý

Přijímá zdravé dobrovolníky

Ne

Popis

Inclusion Criteria:

  • Adults with senile cataract requiring bilateral cataract surgery.
  • Regular corneal astigmatism of ≥1.00 diopter.
  • Axial length between 22.0 mm and 25.0 mm.
  • Eligible for implantation with the TECNIS Eyhance™ Toric II intraocular lens.
  • Able and willing to provide written informed consent.

Exclusion Criteria:

  • Inconsistent corneal astigmatism measurements (difference >0.20 D in magnitude or >5° in axis among the four diagnostic devices).
  • Visually significant dry eye disease with positive corneal fluorescein staining.

Irregular corneal astigmatism or corneal opacity.

  • Ocular comorbidities that could affect toric IOL stability or visual outcomes (e.g., pseudoexfoliation syndrome, advanced glaucoma, or macular pathology).
  • Intraoperative complications or generalized zonular weakness requiring implantation of a capsular tension ring.
  • Significant postoperative day 1 corneal edema precluding reliable rotational measurements.
  • Inability to comply with the follow-up schedule.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Léčba
  • Přidělení: Randomizované
  • Intervenční model: Paralelní přiřazení
  • Maskování: Dvojnásobek

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: OVD-assisted Implantation
Implantation of the TECNIS Eyhance Toric II intraocular lens using a cohesive ophthalmic viscosurgical device (ProVisc) during cataract surgery.
Implantation of the TECNIS Eyhance Toric II intraocular lens using a cohesive ophthalmic viscosurgical device.
Experimentální: BSS-assisted hydroimplantation
Implantation of the TECNIS Eyhance Toric II intraocular lens using balanced salt solution hydroimplantation during cataract surgery.
Implantation of the TECNIS Eyhance Toric II intraocular lens using balanced salt solution instead of an ophthalmic viscosurgical device.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Absolute rotational stability of the TECNIS Eyhance Toric II intraocular lens
Časové okno: Postoperative day 1, week 1, and month 1
Absolute intraocular lens rotation (degrees) measured relative to the final intraoperative implantation axis using the OPD-Scan III. Rotation was calculated as the absolute angular difference between the intraoperative reference axis and the postoperative axis
Postoperative day 1, week 1, and month 1

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Residual refractive astigmatism
Časové okno: 3 months after surgery
Postoperative refractive astigmatism measured at the corneal plane by manifest refraction.
3 months after surgery
Astigmatic prediction error
Časové okno: 3 months after surgery
Absolute prediction error calculated as the absolute difference between the predicted and postoperative refractive astigmatism.
3 months after surgery
Uncorrected Distance Visual Acuity (UDVA)
Časové okno: 3 months after surgery
Monocular uncorrected distance visual acuity measured using a standardized visual acuity chart.
3 months after surgery
Corrected Distance Visual Acuity (CDVA)
Časové okno: 3 months after surgery
3 months after surgery

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Sponzor

Spolupracovníci

Vyšetřovatelé

  • Vrchní vyšetřovatel: Ahmed Assaf, MD, PhD, AinShams university

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

10. dubna 2026

Primární dokončení (Aktuální)

10. června 2026

Dokončení studie (Odhadovaný)

30. srpna 2026

Termíny zápisu do studia

První předloženo

12. srpna 2026

První předloženo, které splnilo kritéria kontroly kvality

12. srpna 2026

První zveřejněno (Aktuální)

17. srpna 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

17. srpna 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

12. srpna 2026

Naposledy ověřeno

1. srpna 2026

Více informací

Termíny související s touto studií

Další relevantní podmínky MeSH

Další identifikační čísla studie

  • 200/2026

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .