Influence of Implantation Technique on Rotational Stability of a Frosted-Haptic Toric Intraocular Lens: A Prospective Contralateral-Eye Study
This prospective, randomized contralateral-eye study evaluates whether the implantation technique influences the rotational stability and refractive outcomes of the TECNIS Eyhance™ Toric II intraocular lens (IOL) during cataract surgery. Although balanced salt solution (BSS) hydroimplantation has been proposed to reduce postoperative IOL rotation by eliminating retained ophthalmic viscosurgical device (OVD), the effect of implantation technique on the rotational stability of modern frosted-haptic toric IOLs remains uncertain.
Patients undergoing bilateral cataract surgery with regular corneal astigmatism receive TECNIS Eyhance™ Toric II IOLs in both eyes. One eye is randomized to OVD-assisted implantation and the fellow eye to BSS-assisted hydroimplantation. The primary outcome is postoperative rotational stability assessed using OPD-Scan III at postoperative day 1, week 1, and month 1. Secondary outcomes include postoperative refractive astigmatism, astigmatic prediction error, and visual acuity. The study aims to determine whether implantation technique influences postoperative rotational stability or refractive performance when using a contemporary frosted-haptic toric IOL.
Przegląd badań
Status
Status
Warunki
Warunki
Interwencja / Leczenie
Interwencja / Leczenie
Typ studiów
Typ studiów
Zapisy (Rzeczywisty)
Zapisy
Faza
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Dr.
-
Cairo, Dr., Egipt, 11765
- AinShams university
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dziecko
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
- Adults with senile cataract requiring bilateral cataract surgery.
- Regular corneal astigmatism of ≥1.00 diopter.
- Axial length between 22.0 mm and 25.0 mm.
- Eligible for implantation with the TECNIS Eyhance™ Toric II intraocular lens.
- Able and willing to provide written informed consent.
Exclusion Criteria:
- Inconsistent corneal astigmatism measurements (difference >0.20 D in magnitude or >5° in axis among the four diagnostic devices).
- Visually significant dry eye disease with positive corneal fluorescein staining.
Irregular corneal astigmatism or corneal opacity.
- Ocular comorbidities that could affect toric IOL stability or visual outcomes (e.g., pseudoexfoliation syndrome, advanced glaucoma, or macular pathology).
- Intraoperative complications or generalized zonular weakness requiring implantation of a capsular tension ring.
- Significant postoperative day 1 corneal edema precluding reliable rotational measurements.
- Inability to comply with the follow-up schedule.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Podwójnie
Liczba ramion
Broń i interwencje
Grupa uczestników / ArmGrupa uczestników / Arm |
Interwencja / LeczenieInterwencja / Leczenie |
|---|---|
|
Eksperymentalny: OVD-assisted Implantation
Implantation of the TECNIS Eyhance Toric II intraocular lens using a cohesive ophthalmic viscosurgical device (ProVisc) during cataract surgery.
|
Implantation of the TECNIS Eyhance Toric II intraocular lens using a cohesive ophthalmic viscosurgical device.
|
|
Eksperymentalny: BSS-assisted hydroimplantation
Implantation of the TECNIS Eyhance Toric II intraocular lens using balanced salt solution hydroimplantation during cataract surgery.
|
Implantation of the TECNIS Eyhance Toric II intraocular lens using balanced salt solution instead of an ophthalmic viscosurgical device.
|
Co mierzy badanie?
Podstawowe miary wyniku
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Absolute rotational stability of the TECNIS Eyhance Toric II intraocular lens
Ramy czasowe: Postoperative day 1, week 1, and month 1
|
Absolute intraocular lens rotation (degrees) measured relative to the final intraoperative implantation axis using the OPD-Scan III.
Rotation was calculated as the absolute angular difference between the intraoperative reference axis and the postoperative axis
|
Postoperative day 1, week 1, and month 1
|
Miary wyników drugorzędnych
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Residual refractive astigmatism
Ramy czasowe: 3 months after surgery
|
Postoperative refractive astigmatism measured at the corneal plane by manifest refraction.
|
3 months after surgery
|
|
Astigmatic prediction error
Ramy czasowe: 3 months after surgery
|
Absolute prediction error calculated as the absolute difference between the predicted and postoperative refractive astigmatism.
|
3 months after surgery
|
|
Uncorrected Distance Visual Acuity (UDVA)
Ramy czasowe: 3 months after surgery
|
Monocular uncorrected distance visual acuity measured using a standardized visual acuity chart.
|
3 months after surgery
|
|
Corrected Distance Visual Acuity (CDVA)
Ramy czasowe: 3 months after surgery
|
3 months after surgery
|
Współpracownicy i badacze
Sponsor
Sponsor
Współpracownicy
Współpracownicy
Śledczy
Śledczy
- Główny śledczy: Ahmed Assaf, MD, PhD, AinShams university
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Zakończenie podstawowe
Ukończenie studiów (Szacowany)
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Pierwszy wysłany
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia wysłana aktualizacja
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
Inne numery identyfikacyjne badania
- 200/2026
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .