Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Comparison Evaluation of the Accuracy of Two Digital Technologies of Measuring Sagittal Condylar Inclination in Edentulous Patients

16. listopadu 2026 aktualizováno: Fuming He
  1. Research background: Measurement, analysis, and in vitro simulation of patient-specific mandibular functional movement constitute one of the key steps in prosthodontic treatment, among which the recording and simulation of protrusive movement are essential components. The path of the condyle during mandibular protrusion is governed by the anatomical features of the temporomandibular joint. When the mandible moves forward, the condyle travels anteroinferiorly within the glenoid fossa; this trajectory is defined as the protrusive condylar path. The angle formed between the protrusive condylar path and the Frankfort horizontal plane is the protrusive condylar path inclination, a critical parameter for characterizing mandibular protrusive movement. Transferring this biological condylar path inclination to an articulator yields the sagittal condylar inclination (SCI), which is represented on the articulator as the angle between the condylar guide groove in the sagittal plane and the reference plane of the articulator. Accurate SCI measurement is of great importance for clinical treatment planning and the fabrication of functional prostheses. Conventional SCI measurement involves multiple procedures: physical facebow transfer, acquisition of stone casts and protrusive interocclusal records, and SCI reading on a mechanical articulator. This workflow is highly technique-sensitive, and its accuracy is susceptible to operator experience, as well as the precision of cast and recording materials. Furthermore, mechanical facebow transfer and conventional impression-taking tend to cause patient discomfort. With advances in digital technology, electronic facebows, which offer high accuracy and favorable repeatability, have been adopted for patient-specific SCI acquisition. Nevertheless, their high cost and relatively cumbersome clinical workflow hinder widespread clinical adoption. Emerging techniques employ a facial scanner to track real-time spatial displacements of intraoral fiducial points. Facial scan data and dental model scans are registered and fused via facial landmarks to visualize and capture the true kinematic trajectories of the mandible and bilateral condyles, with SCI values generated directly. This approach eliminates the need for a facebow or head-mounted apparatus and may confer superior patient comfort. However, studies validating the accuracy of SCI measurements obtained with this workflow remain scarce. Therefore, this study took electronic facebow tracing data as the control to evaluate the accuracy of a fully digital SCI measurement protocol based on Shining intraoral and facial scanning in edentulous patients, providing evidence for the selection of clinical SCI measurement strategies and further optimization of fully digital SCI acquisition technology.
  2. Research objective: To investigate the differences in sagittal condylar inclination (SCI) measured using virtual facebow and virtual interocclusal records versus electronic facebow tracing data during definitive implant rehabilitation of edentulous patients, so as to provide evidence for clinical practice.
  3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study.Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. Edentulous patients who met the eligibility criteria were screened from those receiving implant-supported full-arch provisional restorations and scheduled for definitive rehabilitation at the Stomatological Hospital, Zhejiang University School of Medicine, from the date of ethical approval to August 2028. At the time of definitive impression taking, mandibular movement trajectories were captured and left and right sagittal condylar inclination (SCI) values were recorded using the Zebris electronic facebow and the Shining intraoral and facial scanning system, respectively. All measurements were performed by a single experienced operator. Each measurement method was repeated three times per participant, and the average value was calculated for analysis.

Přehled studie

Postavení

Zatím nenabíráme

Podmínky

Detailní popis

  1. Research background: Measurement, analysis, and in vitro simulation of patient-specific mandibular functional movement constitute one of the key steps in prosthodontic treatment, among which the recording and simulation of protrusive movement are essential components. The path of the condyle during mandibular protrusion is governed by the anatomical features of the temporomandibular joint. When the mandible moves forward, the condyle travels anteroinferiorly within the glenoid fossa; this trajectory is defined as the protrusive condylar path. The angle formed between the protrusive condylar path and the Frankfort horizontal plane is the protrusive condylar path inclination, a critical parameter for characterizing mandibular protrusive movement. Transferring this biological condylar path inclination to an articulator yields the sagittal condylar inclination (SCI), which is represented on the articulator as the angle between the condylar guide groove in the sagittal plane and the reference plane of the articulator. Accurate SCI measurement is of great importance for clinical treatment planning and the fabrication of functional prostheses. Conventional SCI measurement involves multiple procedures: physical facebow transfer, acquisition of stone casts and protrusive interocclusal records, and SCI reading on a mechanical articulator. This workflow is highly technique-sensitive, and its accuracy is susceptible to operator experience, as well as the precision of cast and recording materials. Furthermore, mechanical facebow transfer and conventional impression-taking tend to cause patient discomfort. With advances in digital technology, electronic facebows, which offer high accuracy and favorable repeatability, have been adopted for patient-specific SCI acquisition. Nevertheless, their high cost and relatively cumbersome clinical workflow hinder widespread clinical adoption. Emerging techniques employ a facial scanner to track real-time spatial displacements of intraoral fiducial points. Facial scan data and dental model scans are registered and fused via facial landmarks to visualize and capture the true kinematic trajectories of the mandible and bilateral condyles, with SCI values generated directly. This approach eliminates the need for a facebow or head-mounted apparatus and may confer superior patient comfort. However, studies validating the accuracy of SCI measurements obtained with this workflow remain scarce. Therefore, this study took electronic facebow tracing data as the control to evaluate the accuracy of a fully digital SCI measurement protocol based on Shining intraoral and facial scanning in edentulous patients, providing evidence for the selection of clinical SCI measurement strategies and further optimization of fully digital SCI acquisition technology.
  2. Research objective: To investigate the differences in sagittal condylar inclination (SCI) measured using virtual facebow and virtual interocclusal records versus electronic facebow tracing data during definitive implant rehabilitation of edentulous patients, so as to provide evidence for clinical practice.
  3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study.Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. Edentulous patients meeting the inclusion criteria were screened among candidates who had received implant-supported full-arch provisional restorations and required definitive rehabilitation at the Stomatological Hospital, Zhejiang University School of Medicine, from the date of ethical approval to August 2028. At definitive impression taking, mandibular movement trajectories were recorded, and left and right sagittal condylar inclination (SCI) values were acquired using the Zebris electronic facebow and the Shining intraoral and facial scanning system. All measurements were performed by a single experienced operator. The SCI values were automatically generated by the built-in software of each system. For each participant, every measurement modality was repeated three times, and the mean value was adopted. A visual analogue scale (VAS) questionnaire was used to assess patient comfort during the measurement procedures.

Typ studie

Pozorovací

Zápis (Odhadovaný)

20

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní kontakt

  • Jméno: Fuming He
  • Telefonní číslo: +8613516817697
  • E-mail: hfm@zju.edu.cn

Studijní záloha kontaktů

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

18 let a starší (Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ano

Pohlaví způsobilá ke studiu

Všechno

Metoda odběru vzorků

Vzorek nepravděpodobnosti

Studijní populace

Edentulous patients who met the eligibility criteria were screened from those receiving implant-supported full-arch provisional restorations and scheduled for definitive rehabilitation at the Stomatological Hospital, Zhejiang University School of Medicine, from the date of ethical approval to August 2028.

Popis

Inclusion Criteria:

  1. Patients aged 18years or older
  2. Ability to undergo full-arch implant-supported rehabilitation and receive an implant-supported full-arch acrylic resin provisional prosthesis within 24 h after surgery
  3. Good oral hygiene conditions
  4. The patient is able to understand and actively cooperate with the treatment process, and has signed informed consent

Exclusion Criteria:

  1. Unable to tolerate transplant surgery (due to systemic diseases such as heart disease, hypertension, etc., long history of drug use)
  2. Pregnancy or gestation period
  3. Smokes more than 10 cigarettes a day
  4. The presence of physical defects that may affect transplant surgery
  5. Patients with immune dysfunction, including patients with HIV infection
  6. Local inflammation, including untreated periodontitis
  7. A history of head and neck chemotherapy within a year, or a history of intravenous bisphosphonate use
  8. A habit of severe grinding or clenching of the teeth
  9. Poor oral hygiene or poor compliance
  10. There are benign or malignant tumors in the culture area
  11. Osteoporosis such as severe osteoporosis

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Observační modely: COHORT
  • Časové perspektivy: PROSPECTIVE

Kohorty a intervence

Skupina / kohorta
Zebris electronic facebow group

At the definitive impression stage, mandibular movement trajectories were captured using the Zebris electronic facebow.

SHINING 3D intraoral scan-facial scan fusion multimodal workflow group

At the definitive impression stage, mandibular movement trajectories were captured using the SHINING 3D intraoral scan-facial scan fusion multimodal workflow.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
sagittal condylar inclination (SCI)
Časové okno: From enrollment

The sagittal condylar inclination (SCI) values were automatically exported by the built-in software of both systems.

From enrollment

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
patient satisfaction and comfort
Časové okno: From enrollment

Patient comfort during measurement procedures was assessed using a visual analogue scale (VAS). A 10-cm horizontal line was drawn, anchored at the two ends by the descriptors "most comfortable" (10 cm) and "least comfortable" (0 cm), with no intermediate markings. Immediately after each measurement modality, participants completed the VAS rating to prevent carry-over effects between procedures. A standard ruler was used by the investigator to measure the distance from the left end (0 mm) of the line to the mark made by the participant.

From enrollment

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Sponzor

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Odhadovaný)

26. listopadu 2026

Primární dokončení (Odhadovaný)

31. srpna 2028

Dokončení studie (Odhadovaný)

30. listopadu 2028

Termíny zápisu do studia

První předloženo

16. listopadu 2026

První předloženo, které splnilo kritéria kontroly kvality

16. listopadu 2026

První zveřejněno (Aktuální)

20. listopadu 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

20. listopadu 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

16. listopadu 2026

Naposledy ověřeno

1. srpna 2026

Více informací

Termíny související s touto studií

Další identifikační čísla studie

  • DHZhejiangU-2026(069)

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NE

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .