Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Comparison Evaluation of the Accuracy of Two Digital Technologies of Measuring Sagittal Condylar Inclination in Edentulous Patients

16. November 2026 aktualisiert von: Fuming He
  1. Research background: Measurement, analysis, and in vitro simulation of patient-specific mandibular functional movement constitute one of the key steps in prosthodontic treatment, among which the recording and simulation of protrusive movement are essential components. The path of the condyle during mandibular protrusion is governed by the anatomical features of the temporomandibular joint. When the mandible moves forward, the condyle travels anteroinferiorly within the glenoid fossa; this trajectory is defined as the protrusive condylar path. The angle formed between the protrusive condylar path and the Frankfort horizontal plane is the protrusive condylar path inclination, a critical parameter for characterizing mandibular protrusive movement. Transferring this biological condylar path inclination to an articulator yields the sagittal condylar inclination (SCI), which is represented on the articulator as the angle between the condylar guide groove in the sagittal plane and the reference plane of the articulator. Accurate SCI measurement is of great importance for clinical treatment planning and the fabrication of functional prostheses. Conventional SCI measurement involves multiple procedures: physical facebow transfer, acquisition of stone casts and protrusive interocclusal records, and SCI reading on a mechanical articulator. This workflow is highly technique-sensitive, and its accuracy is susceptible to operator experience, as well as the precision of cast and recording materials. Furthermore, mechanical facebow transfer and conventional impression-taking tend to cause patient discomfort. With advances in digital technology, electronic facebows, which offer high accuracy and favorable repeatability, have been adopted for patient-specific SCI acquisition. Nevertheless, their high cost and relatively cumbersome clinical workflow hinder widespread clinical adoption. Emerging techniques employ a facial scanner to track real-time spatial displacements of intraoral fiducial points. Facial scan data and dental model scans are registered and fused via facial landmarks to visualize and capture the true kinematic trajectories of the mandible and bilateral condyles, with SCI values generated directly. This approach eliminates the need for a facebow or head-mounted apparatus and may confer superior patient comfort. However, studies validating the accuracy of SCI measurements obtained with this workflow remain scarce. Therefore, this study took electronic facebow tracing data as the control to evaluate the accuracy of a fully digital SCI measurement protocol based on Shining intraoral and facial scanning in edentulous patients, providing evidence for the selection of clinical SCI measurement strategies and further optimization of fully digital SCI acquisition technology.
  2. Research objective: To investigate the differences in sagittal condylar inclination (SCI) measured using virtual facebow and virtual interocclusal records versus electronic facebow tracing data during definitive implant rehabilitation of edentulous patients, so as to provide evidence for clinical practice.
  3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study.Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. Edentulous patients who met the eligibility criteria were screened from those receiving implant-supported full-arch provisional restorations and scheduled for definitive rehabilitation at the Stomatological Hospital, Zhejiang University School of Medicine, from the date of ethical approval to August 2028. At the time of definitive impression taking, mandibular movement trajectories were captured and left and right sagittal condylar inclination (SCI) values were recorded using the Zebris electronic facebow and the Shining intraoral and facial scanning system, respectively. All measurements were performed by a single experienced operator. Each measurement method was repeated three times per participant, and the average value was calculated for analysis.

Studienübersicht

Status

Noch keine Rekrutierung

Bedingungen

Detaillierte Beschreibung

  1. Research background: Measurement, analysis, and in vitro simulation of patient-specific mandibular functional movement constitute one of the key steps in prosthodontic treatment, among which the recording and simulation of protrusive movement are essential components. The path of the condyle during mandibular protrusion is governed by the anatomical features of the temporomandibular joint. When the mandible moves forward, the condyle travels anteroinferiorly within the glenoid fossa; this trajectory is defined as the protrusive condylar path. The angle formed between the protrusive condylar path and the Frankfort horizontal plane is the protrusive condylar path inclination, a critical parameter for characterizing mandibular protrusive movement. Transferring this biological condylar path inclination to an articulator yields the sagittal condylar inclination (SCI), which is represented on the articulator as the angle between the condylar guide groove in the sagittal plane and the reference plane of the articulator. Accurate SCI measurement is of great importance for clinical treatment planning and the fabrication of functional prostheses. Conventional SCI measurement involves multiple procedures: physical facebow transfer, acquisition of stone casts and protrusive interocclusal records, and SCI reading on a mechanical articulator. This workflow is highly technique-sensitive, and its accuracy is susceptible to operator experience, as well as the precision of cast and recording materials. Furthermore, mechanical facebow transfer and conventional impression-taking tend to cause patient discomfort. With advances in digital technology, electronic facebows, which offer high accuracy and favorable repeatability, have been adopted for patient-specific SCI acquisition. Nevertheless, their high cost and relatively cumbersome clinical workflow hinder widespread clinical adoption. Emerging techniques employ a facial scanner to track real-time spatial displacements of intraoral fiducial points. Facial scan data and dental model scans are registered and fused via facial landmarks to visualize and capture the true kinematic trajectories of the mandible and bilateral condyles, with SCI values generated directly. This approach eliminates the need for a facebow or head-mounted apparatus and may confer superior patient comfort. However, studies validating the accuracy of SCI measurements obtained with this workflow remain scarce. Therefore, this study took electronic facebow tracing data as the control to evaluate the accuracy of a fully digital SCI measurement protocol based on Shining intraoral and facial scanning in edentulous patients, providing evidence for the selection of clinical SCI measurement strategies and further optimization of fully digital SCI acquisition technology.
  2. Research objective: To investigate the differences in sagittal condylar inclination (SCI) measured using virtual facebow and virtual interocclusal records versus electronic facebow tracing data during definitive implant rehabilitation of edentulous patients, so as to provide evidence for clinical practice.
  3. Study design and methods: Design type: prospective, interventional, single-center, randomized controlled non-inferiority study.Study duration: 2 years. Start time: From the date of adoption of ethics. End time: 2028. Edentulous patients meeting the inclusion criteria were screened among candidates who had received implant-supported full-arch provisional restorations and required definitive rehabilitation at the Stomatological Hospital, Zhejiang University School of Medicine, from the date of ethical approval to August 2028. At definitive impression taking, mandibular movement trajectories were recorded, and left and right sagittal condylar inclination (SCI) values were acquired using the Zebris electronic facebow and the Shining intraoral and facial scanning system. All measurements were performed by a single experienced operator. The SCI values were automatically generated by the built-in software of each system. For each participant, every measurement modality was repeated three times, and the mean value was adopted. A visual analogue scale (VAS) questionnaire was used to assess patient comfort during the measurement procedures.

Studientyp

Beobachtungs

Einschreibung (Geschätzt)

20

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

  • Name: Fuming He
  • Telefonnummer: +8613516817697
  • E-Mail: hfm@zju.edu.cn

Studieren Sie die Kontaktsicherung

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre und älter (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Ja

Studienberechtigte Geschlechter

Alle

Probenahmeverfahren

Nicht-Wahrscheinlichkeitsprobe

Studienpopulation

Edentulous patients who met the eligibility criteria were screened from those receiving implant-supported full-arch provisional restorations and scheduled for definitive rehabilitation at the Stomatological Hospital, Zhejiang University School of Medicine, from the date of ethical approval to August 2028.

Beschreibung

Inclusion Criteria:

  1. Patients aged 18years or older
  2. Ability to undergo full-arch implant-supported rehabilitation and receive an implant-supported full-arch acrylic resin provisional prosthesis within 24 h after surgery
  3. Good oral hygiene conditions
  4. The patient is able to understand and actively cooperate with the treatment process, and has signed informed consent

Exclusion Criteria:

  1. Unable to tolerate transplant surgery (due to systemic diseases such as heart disease, hypertension, etc., long history of drug use)
  2. Pregnancy or gestation period
  3. Smokes more than 10 cigarettes a day
  4. The presence of physical defects that may affect transplant surgery
  5. Patients with immune dysfunction, including patients with HIV infection
  6. Local inflammation, including untreated periodontitis
  7. A history of head and neck chemotherapy within a year, or a history of intravenous bisphosphonate use
  8. A habit of severe grinding or clenching of the teeth
  9. Poor oral hygiene or poor compliance
  10. There are benign or malignant tumors in the culture area
  11. Osteoporosis such as severe osteoporosis

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Beobachtungsmodelle: COHORT
  • Zeitperspektiven: PROSPECTIVE

Kohorten und Interventionen

Gruppe / Kohorte
Zebris electronic facebow group

At the definitive impression stage, mandibular movement trajectories were captured using the Zebris electronic facebow.

SHINING 3D intraoral scan-facial scan fusion multimodal workflow group

At the definitive impression stage, mandibular movement trajectories were captured using the SHINING 3D intraoral scan-facial scan fusion multimodal workflow.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
sagittal condylar inclination (SCI)
Zeitfenster: From enrollment

The sagittal condylar inclination (SCI) values were automatically exported by the built-in software of both systems.

From enrollment

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
patient satisfaction and comfort
Zeitfenster: From enrollment

Patient comfort during measurement procedures was assessed using a visual analogue scale (VAS). A 10-cm horizontal line was drawn, anchored at the two ends by the descriptors "most comfortable" (10 cm) and "least comfortable" (0 cm), with no intermediate markings. Immediately after each measurement modality, participants completed the VAS rating to prevent carry-over effects between procedures. A standard ruler was used by the investigator to measure the distance from the left end (0 mm) of the line to the mark made by the participant.

From enrollment

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

26. November 2026

Primärer Abschluss (Geschätzt)

31. August 2028

Studienabschluss (Geschätzt)

30. November 2028

Studienanmeldedaten

Zuerst eingereicht

16. November 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

16. November 2026

Zuerst gepostet (Tatsächlich)

20. November 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

20. November 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

16. November 2026

Zuletzt verifiziert

1. August 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • DHZhejiangU-2026(069)

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .