The Effect of Different Measurement-manufacturing Techniques on Load Distribution in Amputees

27. března 2020 aktualizováno: Marmara University

The Effect of Different Measurement-manufacturing Techniques on Stump and Soles Load Distribution in Transtibial Knee Prostheses

Alignment of the prosthesis with the stump is performed through the socket. Good socket stump fit provides near-normal posture and weight-transfer pattern. It also ensures that the walk is painless and low-energy. Recently, studies have been carried out to use 3D printers in socket production. 3D method is accepted as an effective and reliable method in prosthetic socket production. The purpose of this study is to compare the pressures distrubution in the sockets produced by conventional and 3D scanners and printers in the transtibial amputee.

Přehled studie

Typ studie

Pozorovací

Zápis (Očekávaný)

30

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

      • Istanbul, Krocan, 34000
        • Marmara University

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

18 let až 70 let (Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ne

Pohlaví způsobilá ke studiu

Všechno

Metoda odběru vzorků

Ukázka pravděpodobnosti

Studijní populace

Unilateral transtibial amputees

Popis

Inclusion Criteria:

  • Being unilateral transtibial amputation
  • To have enough perception level to understand and apply commands

Exclusion Criteria:

  • To have orthopedic, neurological, etc. disorder other than amputation that will affect posture or gait
  • The presence of pain that will affect the posture or walking pattern
  • Wound / tenderness on the stump
  • Visual impairment that will affect the posture or gait pattern
  • Use of any assistive device (walking stick, canary, etc.) during walking

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

Kohorty a intervence

Skupina / kohorta
Intervence / Léčba
Group 1
Unilateral transtibial amputees using conventinional manufactured socket
Presssure disturubition will be measured in conventional manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
Group 2
Unilateral transtibial amputees using 3D manufactured socket
Presssure disturubition will be measured in 3D manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Measurement of load distrubution on stump in conventional manufactured socket
Časové okno: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking.
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
Measurement of load distrubution on stump in 3D manufactured socket
Časové okno: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket sensories during walking.
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
Measurement of load distrubution on stump in conventional manufactured socket
Časové okno: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
Measurement of load distrubution on stump in 3D-manufactured socket
Časové okno: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Časové okno: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Časové okno: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Časové okno: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Časové okno: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Ředitel studie: yasar tatar, Marmara University

Publikace a užitečné odkazy

Osoba odpovědná za zadávání informací o studiu tyto publikace poskytuje dobrovolně. Mohou se týkat čehokoli, co souvisí se studiem.

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

6. září 2019

Primární dokončení (Očekávaný)

10. dubna 2020

Dokončení studie (Očekávaný)

30. června 2020

Termíny zápisu do studia

První předloženo

25. března 2020

První předloženo, které splnilo kritéria kontroly kvality

27. března 2020

První zveřejněno (Aktuální)

30. března 2020

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

30. března 2020

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

27. března 2020

Naposledy ověřeno

1. dubna 2019

Více informací

Termíny související s touto studií

Klíčová slova

Další identifikační čísla studie

  • 09.2019.359

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NEROZHODNÝ

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Klinické studie na conventional manufactured socket

Předplatit