The Effect of Different Measurement-manufacturing Techniques on Load Distribution in Amputees
27 марта 2020 г. обновлено: Marmara University
The Effect of Different Measurement-manufacturing Techniques on Stump and Soles Load Distribution in Transtibial Knee Prostheses
Alignment of the prosthesis with the stump is performed through the socket.
Good socket stump fit provides near-normal posture and weight-transfer pattern.
It also ensures that the walk is painless and low-energy.
Recently, studies have been carried out to use 3D printers in socket production.
3D method is accepted as an effective and reliable method in prosthetic socket production.
The purpose of this study is to compare the pressures distrubution in the sockets produced by conventional and 3D scanners and printers in the transtibial amputee.
Обзор исследования
Статус
Неизвестный
Вмешательство/лечение
Тип исследования
Наблюдательный
Регистрация (Ожидаемый)
30
Контакты и местонахождение
В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.
Места учебы
-
-
-
Istanbul, Турция, 34000
- Marmara University
-
-
Критерии участия
Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.
Критерии приемлемости
Возраст, подходящий для обучения
От 18 лет до 70 лет (Взрослый, Пожилой взрослый)
Принимает здоровых добровольцев
Нет
Полы, имеющие право на обучение
Все
Метод выборки
Вероятностная выборка
Исследуемая популяция
Unilateral transtibial amputees
Описание
Inclusion Criteria:
- Being unilateral transtibial amputation
- To have enough perception level to understand and apply commands
Exclusion Criteria:
- To have orthopedic, neurological, etc. disorder other than amputation that will affect posture or gait
- The presence of pain that will affect the posture or walking pattern
- Wound / tenderness on the stump
- Visual impairment that will affect the posture or gait pattern
- Use of any assistive device (walking stick, canary, etc.) during walking
Учебный план
В этом разделе представлена подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.
Как устроено исследование?
Детали дизайна
Когорты и вмешательства
Группа / когорта |
Вмешательство/лечение |
|---|---|
|
Group 1
Unilateral transtibial amputees using conventinional manufactured socket
|
Presssure disturubition will be measured in conventional manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
|
|
Group 2
Unilateral transtibial amputees using 3D manufactured socket
|
Presssure disturubition will be measured in 3D manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Measurement of load distrubution on stump in conventional manufactured socket
Временное ограничение: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
|
Measurement of load distrubution on stump in 3D manufactured socket
Временное ограничение: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket sensories during walking.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
|
Measurement of load distrubution on stump in conventional manufactured socket
Временное ограничение: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
|
Measurement of load distrubution on stump in 3D-manufactured socket
Временное ограничение: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Временное ограничение: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Временное ограничение: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Временное ограничение: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Временное ограничение: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Соавторы и исследователи
Здесь вы найдете людей и организации, участвующие в этом исследовании.
Спонсор
Следователи
- Директор по исследованиям: yasar tatar, Marmara University
Публикации и полезные ссылки
Лицо, ответственное за внесение сведений об исследовании, добровольно предоставляет эти публикации. Это может быть что угодно, связанное с исследованием.
Общие публикации
- Dou P, Jia X, Suo S, Wang R, Zhang M. Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road. Clin Biomech (Bristol, Avon). 2006 Dec;21(10):1067-73. doi: 10.1016/j.clinbiomech.2006.06.004. Epub 2006 Aug 17.
- Jia X, Suo S, Meng F, Wang R. Effects of alignment on interface pressure for transtibial amputee during walking. Disabil Rehabil Assist Technol. 2008 Nov;3(6):339-43. doi: 10.1080/17483100802044634.
- Xiaohong J, Xiaobing L, Peng D, Ming Z. The Influence of Dynamic Trans-tibial Prosthetic Alignment on Standing Plantar Foot Pressure. Conf Proc IEEE Eng Med Biol Soc. 2005;2005:6916-8. doi: 10.1109/IEMBS.2005.1616096.
- Lee VS, Solomonidis SE, Spence WD. Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study. Proc Inst Mech Eng H. 1997;211(2):167-80. doi: 10.1243/0954411971534287.
Даты записи исследования
Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.
Изучение основных дат
Начало исследования (Действительный)
6 сентября 2019 г.
Первичное завершение (Ожидаемый)
10 апреля 2020 г.
Завершение исследования (Ожидаемый)
30 июня 2020 г.
Даты регистрации исследования
Первый отправленный
25 марта 2020 г.
Впервые представлено, что соответствует критериям контроля качества
27 марта 2020 г.
Первый опубликованный (Действительный)
30 марта 2020 г.
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
30 марта 2020 г.
Последнее отправленное обновление, отвечающее критериям контроля качества
27 марта 2020 г.
Последняя проверка
1 апреля 2019 г.
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Другие идентификационные номера исследования
- 09.2019.359
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
НЕ РЕШЕНО
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Нет
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Нет
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .