The Effect of Different Measurement-manufacturing Techniques on Load Distribution in Amputees
27. mars 2020 oppdatert av: Marmara University
The Effect of Different Measurement-manufacturing Techniques on Stump and Soles Load Distribution in Transtibial Knee Prostheses
Alignment of the prosthesis with the stump is performed through the socket.
Good socket stump fit provides near-normal posture and weight-transfer pattern.
It also ensures that the walk is painless and low-energy.
Recently, studies have been carried out to use 3D printers in socket production.
3D method is accepted as an effective and reliable method in prosthetic socket production.
The purpose of this study is to compare the pressures distrubution in the sockets produced by conventional and 3D scanners and printers in the transtibial amputee.
Studieoversikt
Status
Ukjent
Forhold
Intervensjon / Behandling
Studietype
Observasjonsmessig
Registrering (Forventet)
30
Kontakter og plasseringer
Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.
Studiesteder
-
-
-
Istanbul, Tyrkia, 34000
- Marmara University
-
-
Deltakelseskriterier
Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
18 år til 70 år (Voksen, Eldre voksen)
Tar imot friske frivillige
Nei
Kjønn som er kvalifisert for studier
Alle
Prøvetakingsmetode
Sannsynlighetsprøve
Studiepopulasjon
Unilateral transtibial amputees
Beskrivelse
Inclusion Criteria:
- Being unilateral transtibial amputation
- To have enough perception level to understand and apply commands
Exclusion Criteria:
- To have orthopedic, neurological, etc. disorder other than amputation that will affect posture or gait
- The presence of pain that will affect the posture or walking pattern
- Wound / tenderness on the stump
- Visual impairment that will affect the posture or gait pattern
- Use of any assistive device (walking stick, canary, etc.) during walking
Studieplan
Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.
Hvordan er studiet utformet?
Designdetaljer
Kohorter og intervensjoner
Gruppe / Kohort |
Intervensjon / Behandling |
|---|---|
|
Group 1
Unilateral transtibial amputees using conventinional manufactured socket
|
Presssure disturubition will be measured in conventional manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
|
|
Group 2
Unilateral transtibial amputees using 3D manufactured socket
|
Presssure disturubition will be measured in 3D manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Measurement of load distrubution on stump in conventional manufactured socket
Tidsramme: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
|
Measurement of load distrubution on stump in 3D manufactured socket
Tidsramme: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket sensories during walking.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
|
Measurement of load distrubution on stump in conventional manufactured socket
Tidsramme: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
|
Measurement of load distrubution on stump in 3D-manufactured socket
Tidsramme: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Tidsramme: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Tidsramme: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Tidsramme: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Tidsramme: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Samarbeidspartnere og etterforskere
Det er her du vil finne personer og organisasjoner som er involvert i denne studien.
Sponsor
Etterforskere
- Studieleder: yasar tatar, Marmara University
Publikasjoner og nyttige lenker
Den som er ansvarlig for å legge inn informasjon om studien leverer frivillig disse publikasjonene. Disse kan handle om alt relatert til studiet.
Generelle publikasjoner
- Dou P, Jia X, Suo S, Wang R, Zhang M. Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road. Clin Biomech (Bristol, Avon). 2006 Dec;21(10):1067-73. doi: 10.1016/j.clinbiomech.2006.06.004. Epub 2006 Aug 17.
- Jia X, Suo S, Meng F, Wang R. Effects of alignment on interface pressure for transtibial amputee during walking. Disabil Rehabil Assist Technol. 2008 Nov;3(6):339-43. doi: 10.1080/17483100802044634.
- Xiaohong J, Xiaobing L, Peng D, Ming Z. The Influence of Dynamic Trans-tibial Prosthetic Alignment on Standing Plantar Foot Pressure. Conf Proc IEEE Eng Med Biol Soc. 2005;2005:6916-8. doi: 10.1109/IEMBS.2005.1616096.
- Lee VS, Solomonidis SE, Spence WD. Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study. Proc Inst Mech Eng H. 1997;211(2):167-80. doi: 10.1243/0954411971534287.
Studierekorddatoer
Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.
Studer hoveddatoer
Studiestart (Faktiske)
6. september 2019
Primær fullføring (Forventet)
10. april 2020
Studiet fullført (Forventet)
30. juni 2020
Datoer for studieregistrering
Først innsendt
25. mars 2020
Først innsendt som oppfylte QC-kriteriene
27. mars 2020
Først lagt ut (Faktiske)
30. mars 2020
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
30. mars 2020
Siste oppdatering sendt inn som oppfylte QC-kriteriene
27. mars 2020
Sist bekreftet
1. april 2019
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Andre studie-ID-numre
- 09.2019.359
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
UBESLUTTE
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Nei
Studerer et amerikansk FDA-regulert enhetsprodukt
Nei
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .