The Effect of Different Measurement-manufacturing Techniques on Load Distribution in Amputees
27 de marzo de 2020 actualizado por: Marmara University
The Effect of Different Measurement-manufacturing Techniques on Stump and Soles Load Distribution in Transtibial Knee Prostheses
Alignment of the prosthesis with the stump is performed through the socket.
Good socket stump fit provides near-normal posture and weight-transfer pattern.
It also ensures that the walk is painless and low-energy.
Recently, studies have been carried out to use 3D printers in socket production.
3D method is accepted as an effective and reliable method in prosthetic socket production.
The purpose of this study is to compare the pressures distrubution in the sockets produced by conventional and 3D scanners and printers in the transtibial amputee.
Descripción general del estudio
Estado
Desconocido
Condiciones
Intervención / Tratamiento
Tipo de estudio
De observación
Inscripción (Anticipado)
30
Contactos y Ubicaciones
Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.
Ubicaciones de estudio
-
-
-
Istanbul, Pavo, 34000
- Marmara University
-
-
Criterios de participación
Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.
Criterio de elegibilidad
Edades elegibles para estudiar
18 años a 70 años (Adulto, Adulto Mayor)
Acepta Voluntarios Saludables
No
Géneros elegibles para el estudio
Todos
Método de muestreo
Muestra de probabilidad
Población de estudio
Unilateral transtibial amputees
Descripción
Inclusion Criteria:
- Being unilateral transtibial amputation
- To have enough perception level to understand and apply commands
Exclusion Criteria:
- To have orthopedic, neurological, etc. disorder other than amputation that will affect posture or gait
- The presence of pain that will affect the posture or walking pattern
- Wound / tenderness on the stump
- Visual impairment that will affect the posture or gait pattern
- Use of any assistive device (walking stick, canary, etc.) during walking
Plan de estudios
Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.
¿Cómo está diseñado el estudio?
Detalles de diseño
Cohortes e Intervenciones
Grupo / Cohorte |
Intervención / Tratamiento |
|---|---|
|
Group 1
Unilateral transtibial amputees using conventinional manufactured socket
|
Presssure disturubition will be measured in conventional manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
|
|
Group 2
Unilateral transtibial amputees using 3D manufactured socket
|
Presssure disturubition will be measured in 3D manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Measurement of load distrubution on stump in conventional manufactured socket
Periodo de tiempo: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
|
Measurement of load distrubution on stump in 3D manufactured socket
Periodo de tiempo: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket sensories during walking.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
|
|
Measurement of load distrubution on stump in conventional manufactured socket
Periodo de tiempo: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
|
|
Measurement of load distrubution on stump in 3D-manufactured socket
Periodo de tiempo: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Periodo de tiempo: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Periodo de tiempo: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Periodo de tiempo: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
|
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Periodo de tiempo: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
|
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
|
Colaboradores e Investigadores
Aquí es donde encontrará personas y organizaciones involucradas en este estudio.
Patrocinador
Investigadores
- Director de estudio: yasar tatar, Marmara University
Publicaciones y enlaces útiles
La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.
Publicaciones Generales
- Dou P, Jia X, Suo S, Wang R, Zhang M. Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road. Clin Biomech (Bristol, Avon). 2006 Dec;21(10):1067-73. doi: 10.1016/j.clinbiomech.2006.06.004. Epub 2006 Aug 17.
- Jia X, Suo S, Meng F, Wang R. Effects of alignment on interface pressure for transtibial amputee during walking. Disabil Rehabil Assist Technol. 2008 Nov;3(6):339-43. doi: 10.1080/17483100802044634.
- Xiaohong J, Xiaobing L, Peng D, Ming Z. The Influence of Dynamic Trans-tibial Prosthetic Alignment on Standing Plantar Foot Pressure. Conf Proc IEEE Eng Med Biol Soc. 2005;2005:6916-8. doi: 10.1109/IEMBS.2005.1616096.
- Lee VS, Solomonidis SE, Spence WD. Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study. Proc Inst Mech Eng H. 1997;211(2):167-80. doi: 10.1243/0954411971534287.
Fechas de registro del estudio
Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.
Fechas importantes del estudio
Inicio del estudio (Actual)
6 de septiembre de 2019
Finalización primaria (Anticipado)
10 de abril de 2020
Finalización del estudio (Anticipado)
30 de junio de 2020
Fechas de registro del estudio
Enviado por primera vez
25 de marzo de 2020
Primero enviado que cumplió con los criterios de control de calidad
27 de marzo de 2020
Publicado por primera vez (Actual)
30 de marzo de 2020
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
30 de marzo de 2020
Última actualización enviada que cumplió con los criterios de control de calidad
27 de marzo de 2020
Última verificación
1 de abril de 2019
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- 09.2019.359
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
INDECISO
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
No
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
No
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .