The Effect of Different Measurement-manufacturing Techniques on Load Distribution in Amputees

27 mars 2020 mis à jour par: Marmara University

The Effect of Different Measurement-manufacturing Techniques on Stump and Soles Load Distribution in Transtibial Knee Prostheses

Alignment of the prosthesis with the stump is performed through the socket. Good socket stump fit provides near-normal posture and weight-transfer pattern. It also ensures that the walk is painless and low-energy. Recently, studies have been carried out to use 3D printers in socket production. 3D method is accepted as an effective and reliable method in prosthetic socket production. The purpose of this study is to compare the pressures distrubution in the sockets produced by conventional and 3D scanners and printers in the transtibial amputee.

Aperçu de l'étude

Type d'étude

Observationnel

Inscription (Anticipé)

30

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

      • Istanbul, Turquie, 34000
        • Marmara University

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans à 70 ans (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon de probabilité

Population étudiée

Unilateral transtibial amputees

La description

Inclusion Criteria:

  • Being unilateral transtibial amputation
  • To have enough perception level to understand and apply commands

Exclusion Criteria:

  • To have orthopedic, neurological, etc. disorder other than amputation that will affect posture or gait
  • The presence of pain that will affect the posture or walking pattern
  • Wound / tenderness on the stump
  • Visual impairment that will affect the posture or gait pattern
  • Use of any assistive device (walking stick, canary, etc.) during walking

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
Group 1
Unilateral transtibial amputees using conventinional manufactured socket
Presssure disturubition will be measured in conventional manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees
Group 2
Unilateral transtibial amputees using 3D manufactured socket
Presssure disturubition will be measured in 3D manufactured socket during walking and stairing up and down activities in unilateral transtibial amputees

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Measurement of load distrubution on stump in conventional manufactured socket
Délai: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking.
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
Measurement of load distrubution on stump in 3D manufactured socket
Délai: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket sensories during walking.
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during walking
Measurement of load distrubution on stump in conventional manufactured socket
Délai: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs.
Measurement of load distrubution on stump in 3D-manufactured socket
Délai: Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
Load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
Change from load distrubution (mmHg/N/Kg) on stump will be measured with F-socket film sensories during climbing up and down stairs
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Délai: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Délai: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during walking
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during walking
Measurement of sole load distrubution (mmHg/N/Kg) in conventional manufactured socket
Délai: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
Measurement of sole load distrubution (mmHg/N/Kg) in 3D-manufactured socket
Délai: Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs
Sole load distrubution (mmHg/N/Kg) will be measured with F-scan sensories during climbing up and down stairs
Change from sole load distrubution (mmHg/N/Kg) will be measured with F-socket film sensories during climbing up and down stairs

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Les enquêteurs

  • Directeur d'études: yasar tatar, Marmara University

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

6 septembre 2019

Achèvement primaire (Anticipé)

10 avril 2020

Achèvement de l'étude (Anticipé)

30 juin 2020

Dates d'inscription aux études

Première soumission

25 mars 2020

Première soumission répondant aux critères de contrôle qualité

27 mars 2020

Première publication (Réel)

30 mars 2020

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

30 mars 2020

Dernière mise à jour soumise répondant aux critères de contrôle qualité

27 mars 2020

Dernière vérification

1 avril 2019

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • 09.2019.359

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

INDÉCIS

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .