Preoxygenation in the Intensive Care Unit Using a Nose-mouth Mask Versus High-flow Nasal Cannula Oxygen.
Prospective Randomised Study on Preoxygenation in the Intensive Care Unit Using a Nose-mouth Mask Versus High Flow Nasal Cannula Oxygen.
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Fase
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
-
Hamburg, Tyskland, 20246
- Universitätsklinikum Hamburg-Eppendorf, Department of Intensive Care Medicine
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- patients treated in an intensive care unit
- indication for intubation
- presence of hypoxemic (SaO2/fraction of inspired oxygen(FiO2): 300 or less) respiratory failure
- informed consent
Exclusion Criteria:
- blocked nasopharynx
- contraindications for nose-mouth mask or high flow nasal cannula oxygen
- expected difficult airway
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Ingen (Åben etiket)
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Aktiv komparator: Nose-mouth mask
Performance of intubation after preoxygenation using a nose-mouth mask.
|
Preoxygenation using a nose-mouth mask.
Intubation
|
|
Eksperimentel: High flow nasal cannula oxygen
Performance of intubation after preoxygenation using high flow nasal cannula oxygen.
|
Intubation
Preoxygenation using high flow nasal cannula oxygen.
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Mean decrease in the saturation of oxygen (SpO2) during intubation.
Tidsramme: during intubation
|
Mean decrease in the saturation of oxygen measured by pulse oximetry (SpO2 [%]) during intubation.
|
during intubation
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Changes in blood gases after intubation.
Tidsramme: 30 minutes after intubation
|
Changes in arterial blood gases collected from arterial line (PaO2/FiO2 [mmHg] and PaCO2 [mmHg]) after intubation.
|
30 minutes after intubation
|
Andre resultatmål
Andre resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Changes in hemodynamics.
Tidsramme: during intubation and up to 30 minutes after intubation
|
Changes in mean arterial pressure [mmHg] measured via arterial line.
|
during intubation and up to 30 minutes after intubation
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Publikationer og nyttige links
Datoer for undersøgelser
Studer store datoer
Studiestart
Studiestart
Primær færdiggørelse (Faktiske)
Primær færdiggørelse
Studieafslutning (Faktiske)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Skøn)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- PV-4429
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .