Can Transcutaneous Electrical Acupoint Stimulation Improve the Quality of Recovery After Thyroidectomy?
The Effects of Transcutaneous Electrical Acupoint Stimulation on the Quality of Recovery After Thyroidectomy Surgery
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Detaljeret beskrivelse
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Fase
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
Fujian
-
Fuzhou, Fujian, Kina, 350001
- Fujian Provincial Hospital
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- Consecutive female patients aged 18 to 60 with American Society of Anesthesiologists physical status (ASA) physical status I or II, who underwent general anesthesia for elective thyroidectomy surgery
Exclusion Criteria:
- potentially difficult airway,
- a history of chronic pain,
- drug or alcohol abuse,
- mental disorder,
- intake of any analgesic drug within 48 h before surgery, and
- previous experience with acupuncture treatment
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Forebyggelse
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Firedobbelt
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Eksperimentel: the TEAS group
Patients in the TEAS group received pre-operative TEAS for 30 min before the induction of anesthesia using the Hans electronic acupuncture apparatus (HANS-100A, Nanjing Jisheng Medical Technology Company, Nanjing, China) in the holding area.
TEAS was applied to two pairs of acupoints: bilateral Hegu (LI4) and Neiguan (PC6).
|
TEAS was performed with a dense-disperse frequency of 2/10 Hz and an intensity of 6-9 mA for 30 min using the Hans electronic acupuncture apparatus (HANS-100A, Nanjing Jisheng Medical Technology Company, Nanjing, China).
|
|
Sham-komparator: the sham group
In the sham group, the patients were connected to the Hans electronic acupuncture apparatus (HANS-100A, Nanjing Jisheng Medical Technology Company, Nanjing, China), but electronic stimulation was not applied.
|
TEAS was performed with a dense-disperse frequency of 2/10 Hz and an intensity of 6-9 mA for 30 min using the Hans electronic acupuncture apparatus (HANS-100A, Nanjing Jisheng Medical Technology Company, Nanjing, China).
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
the quality of recovery, as measured by a 40-item questionnaire
Tidsramme: 24 hours after surgery
|
The primary outcome was the quality of recovery, which was assessed on the day before surgery and 24 h after surgery using a 40-item questionnaire (QoR-40)
|
24 hours after surgery
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
the incidence of postoperative nausea and vomiting
Tidsramme: 24 hours after surgery
|
24 hours after surgery
|
|
postoperative pain intensity, as assessed using Visual Analogue Scale (VAS)
Tidsramme: 24 hours after surgery
|
24 hours after surgery
|
|
patient's satisfaction, as evaluated with a 10-point numerical rating scale: 10= excellent, 1= bad.
Tidsramme: at 24 hours after surgery
|
at 24 hours after surgery
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Efterforskere
Efterforskere
- Studieleder: Yanqing Chen, MD, Fujian Provincial Hospital, China
Publikationer og nyttige links
Datoer for undersøgelser
Studer store datoer
Studiestart
Studiestart
Primær færdiggørelse (Faktiske)
Primær færdiggørelse
Studieafslutning (Faktiske)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Skøn)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Skøn)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- K2014-12-003
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .