Application of Ultrasonic Elastography in Lung Lesions
Transthoracic Ultrasound Elastography in Pulmonary Lesions and Diseases
Elastography is an imaging of tissue elasticity or stiffness and is currently emerging as a mainstream tool for ultrasound-based diagnosis. This compressibility property of materials, mathematically expressed as the change in tissue displacement as a function of its distance from the compressing device, is known as strain and is the parameter that is imaged in an elastogram.
Elastography has currently shown promising result in differentiating viscoelastic nature of various organs, which is a consequence of certain underlying diseases.
At present, there are limited literatures revealing the application and feasibility of ultrasonic elastography in lung lesions. This is essentially important as it may serve as an adjuvant to B-mode ultrasound. The investigators aimed at exploring the application and feasibility of ultrasonic elastography on lung lesions.
Studieoversigt
Status
Status
Betingelser
Betingelser
Detaljeret beskrivelse
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Kontakter og lokationer
Studiesteder
-
-
Taipei City
-
Taipei, Taipei City, Taiwan, 100
- National Taiwan University Hospital
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Prøveudtagningsmetode
Studiebefolkning
Beskrivelse
A. Inclusion Criteria:
Patients with radiographic findings of:
- consolidation
- obstructive pneumonitis
- tumors
B. Exclusion Criteria:
- Patients with poor acoustic window
- Unable to hold breathing
- Not cooperative
- Presence of pleural effusion
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Comparison of strain ratio between necrosis, atelectasis, consolidation and tumor
Tidsramme: Up to 15 months
|
The strain ratio was measured under ultrasonic elastography.
At least three measurements were performed each time and we average all the measurements as the final strain ratio.
Independent t test was used for comparison.
|
Up to 15 months
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Efterforskere
Efterforskere
- Ledende efterforsker: Hao-Chien Wang, MD, PhD, National Taiwan University Hospital
Publikationer og nyttige links
Datoer for undersøgelser
Studer store datoer
Studiestart
Studiestart
Primær færdiggørelse (Faktiske)
Primær færdiggørelse
Studieafslutning (Faktiske)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Skøn)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Skøn)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- 201503075RINC
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .