Evaluation of Electronic LogMar Visual Acuity and Contrast Sensitivity in a Population of Contact Lens Wearers
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Fase
Fase
- Fase 4
Kontakter og lokationer
Studiesteder
-
-
Florida
-
Jacksonville, Florida, Forenede Stater, 32256
- VRC East
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
Potential subjects must satisfy all of the following criteria to be enrolled in the study:
- The subject must read, understand, and sign the STATEMENT OF INFORMED CONSENT and receive a fully executed copy of the form
- Appear able and willing to adhere to the instructions set forth in this clinical protocol
- Between 18 and 35 (inclusive) years of age at the time of screening
- The subject must be habitual contact lens wearers (defined as minimum 6 hours per day, 5 days a week over the last month)
The subject must meet all of the following three criteria:
- The eyes' spherical equivalent distance refraction must be in the range of -1.00 to -9.00 D (inclusive)
- The eyes' refractive cylinder must be less than or equal to -0.75 DC
- Each eye must have best corrected visual acuity of 20/25 or better.
- The subject must have normal eyes (i.e., no ocular medications or infections of any type)
Exclusion Criteria:
Potential subjects who meet any of the following criteria will be excluded from participating in the study:
- Currently pregnant or lactating
- Any systemic disease (e.g., Sjögren's Syndrome), allergies, infectious disease (e.g., hepatitis, tuberculosis), contagious immunosuppressive diseases (e.g., HIV), autoimmune disease (e.g. rheumatoid arthritis), or other diseases, by self-report, which are known to interfere with contact lens wear and/or participation in the study
- Use of systemic medications (e.g., chronic steroid use) that are known to interfere with contact lens wear or may impact the functioning of the tear film (e.g., Isotretinoin)
- Any ocular allergies, infections or other ocular abnormalities that are known to interfere with contact lens wear and/or participation in the study. This may include, but not be limited to entropion, ectropion, extrusions, chalazia, recurrent styes, glaucoma, history of recurrent corneal erosions, aphakia, or corneal distortion
- Any current use of ocular medication
- Any previous, or planned (during the course of the study) ocular surgery (e.g., radial keratotomy, PRK, LASIK, etc.)
- Any Grade 3 or greater slit lamp findings (e.g., edema, corneal neovascularization, corneal staining, tarsal abnormalities, conjunctival injection) on the Efron scale
- Any previous history or signs of a contact lens-related corneal inflammatory event (e.g., past peripheral ulcer or round peripheral scar), or any other ocular abnormality that would contraindicate contact lens wear
- Any known hypersensitivity or allergic reaction to contact lens care products.
- Participation in any contact lens or lens care product clinical trial within 30 days prior to study enrollment
- Employee of clinical site (e.g., Investigator, Coordinator, Technician)
- Current wearers of Acuvue Oasys 1-Day brand contact lenses
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: Randomiseret
- Interventionel model: Crossover opgave
- Maskning: Enkelt
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Eksperimentel: TEST/SCR
Subjects who are current soft contact lens wearers between the ages of 18 and 35 will be randomized to the two different treatments (TEST/SCR) sequentially
|
Acuvue Oasys 1-Day
Trial Frame with best spherocylindrical refraction (SCR)
|
|
Eksperimentel: SCR/TEST
Subjects who are current soft contact lens wearers between the ages of 18 and 35 will be randomized to the two different treatments (SCR/TEST) sequentially
|
Acuvue Oasys 1-Day
Trial Frame with best spherocylindrical refraction (SCR)
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Visual Acuity (logMAR)
Tidsramme: 15 Minutes post Treatment Administration
|
Visual Acuity was collected electronically under two conditions (high luminance low contrast and low luminance high contrast) in both eyes 15- minutes post study article administration.
The average visual acuity for each lens type and condition was reported.
|
15 Minutes post Treatment Administration
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Area Under Contrast Sensitivity Function Curve
Tidsramme: 15 minutes post treatment administration
|
Contrast sensitivity was assessed in both eyes at 1.5, 3.0, 6.0, 12.5 and 18.0 cycles per degrees (cpd) using AST Sentio vision Testing System.
During testing 25 triplets of test letters were displayed on a large stationary monitor (118 CM), the operator recorded the patients responses using the remote (Android Tablet).
After a testing session had been completed the software calculated the Area under the log contrast sensitivity function from 1.5 cpd to 18 cpd.
|
15 minutes post treatment administration
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Studiestart
Primær færdiggørelse (Faktiske)
Primær færdiggørelse
Studieafslutning (Faktiske)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- CR-5968
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
produkt fremstillet i og eksporteret fra U.S.A.
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .
Kliniske forsøg med Synsstyrke
-
NCT05026658Afsluttet
-
NCT04530773AfsluttetVisual Health of Virtual Reality
-
NCT05530148AfsluttetKognitiv forandring | Behandling, Visual Spatial
-
NCT04760054AfsluttetKognitiv forandring | Arbejdshukommelse | Hæmning (psykologi) | Behandling, Visual Spatial
-
NCT04110015AfsluttetGrøn stær | Nethindesygdom | Visual Pathway Disorder
-
NCT04607369Tilmelding efter invitationMakula sygdom | Visual Pathway Disorder | Synsnervesygdom
-
NCT05524493RekrutteringEpilepsi | Migræne | Visuelt snesyndrom
-
NCT01089101Aktiv, ikke rekrutterendeGliom af lav grad | Tilbagevendende Visual Pathway Gliom | Refractory Visual Pathway Gliom | Tilbagevendende pilocytisk astrocytom i barndommen | Tilbagevendende neurofibromatose type 1 | Refraktær neurofibromatose type 1
-
NCT05647421RekrutteringVisual til at sammenligne det visuelle resultat mellem AcrySof™ IQ Vivity™ og TECNIS Synergy™ intraokulær linse (model ZFR00V)
Kliniske forsøg med senofilcon A
-
NCT01990664Afsluttet
-
NCT03556579Afsluttet
-
NCT02982018Afsluttet
-
NCT03475875AfsluttetKorrektion af refraktionsfejl | Dæmpning af skarpt lys
-
NCT03581825Afsluttet
-
NCT01819194AfsluttetMeibomisk kirtel dysfunktion