NGS Strategy Effectiveness in Molecular Diagnosis
The coming out of Next Generation Sequencing (NGS) technologies, with documented advantages and reduced costs respect to Sanger sequencing, has provided new appealing approaches to diagnostic testing. Despite this, its use for routine diagnostic purposes requires certification in terms of reliability, as well as a cost-effectiveness evaluation.
To test the feasibility of using the Ion Torrent Personal Genome Machine (PGM) in clinical diagnosis, we assessed its performance to detect point mutations and big rearrangements previously identified with standard techniques. The diagnostic accuracy and the cost-effectiveness will be evaluated by Health Technology Assessment (HTA) analyses.
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
- Barn
- Voksen
- Ældre voksen
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Prøveudtagningsmetode
Studiebefolkning
Beskrivelse
Inclusion Criteria:
- Clinical diagnosis of Multiple Osteochondroma
- Clinical diagnosis of Osteogenesis Imperfecta
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
Antal grupper/kohorter
Kohorter og interventioner
Gruppe / kohorteGruppe / kohorte |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
MO patients
|
|
|
OI patients
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Assessment of the accuracy of the Ion Torrent PGM platform for genetic variant detection (Diagnostic sensitivity evaluation)
Tidsramme: at 30 months
|
The accuracy of the Ion Torrent Personal Genome (PGM) to identify disease-causing mutations in patients affected by Multiple Osteochondromas (MO) and Osteogenesis Imperfecta (OI) needs to be validated for its routine diagnostic clinical use.
To asses this, we will compare results obtained with the new NGS approach with those previously obtained with standard techniques (DHPLC/Sanger + MLPA) in a number of MO and OI patients.
|
at 30 months
|
|
HTA analysis to assess the cost-effectiveness, organizational and social implications of a screening strategy based on the IonPGM platform
Tidsramme: at 36 months
|
To demonstrate the pertinence in the use of this innovative technology in health care, we will examine the medical, social and economic implications according with Health Technology Assessment (HTA), a multi-disciplinary field of policy analysis applied to many different health care technologies before their diffusion and use.
HTA aims at evaluating the real effectiveness of medical interventions, their proper use, access criteria and qualitative improvements, the clinical and organizational benefits, therefore suggesting how to manage, promote and discourage them.
|
at 36 months
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Samarbejdspartnere
Samarbejdspartnere
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Studiestart
Primær færdiggørelse (Faktiske)
Primær færdiggørelse
Studieafslutning (Faktiske)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
- Neoplasmer, bindevæv og blødt væv
- Neoplasmer efter histologisk type
- Neoplasmer
- Genetiske sygdomme, medfødte
- Muskuloskeletale sygdomme
- Bindevævssygdomme
- Knoglesygdomme
- Neoplastiske syndromer, arvelig
- Neoplasmer, Knoglevæv
- Neoplasmer, bindevæv
- Knoglesygdomme, udviklingsmæssige
- Osteochondrodysplasier
- Kollagensygdomme
- Exostoser
- Hyperostose
- Osteogenesis Imperfecta
- Osteochondrom
- Exostoser, multiple arvelige
- Osteochondromatose
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- PRUA1GR-2013-00000177
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
IPD-planbeskrivelse
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .