Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Hyperpolarized MR Imaging With Carbon-13 Pyruvate in the Human Body (POLARIC-13)

12. november 2026 opdateret af: National Heart Centre Singapore

Positron emission tomography with 18F fluorodeoxyglucose (FDG) is the conventional imaging technique to provide information regarding tissue glucose uptake and has been highly clinically successful. However, it cannot assess downstream metabolism, which may be useful in the diagnosis and assessment of treatment response in a variety of diseases. Patients will also be exposed to ionizing radiation, the amount of exposure can vary depending on the dose of tracer administered, frequency of scans and duration of each scan. Carbon-13 (13C) magnetic resonance imaging (MRI) is particularly attractive for metabolic imaging because carbon serves as the backbone of nearly all organic molecules in the body. With this technique, the polarization increases to approximately 30%-40%, an increase of over 10,000 to 100,000-fold, thereby dramatically increasing the MRI signal . Whilst the role of 13C imaging has been demonstrated in many sites around the world, we aim to demonstrate the feasibility and application of 13C hyperpolarized imaging in healthy Singapore residents and patients with cardiovascular and/or cardiometabolic diseases.

Studieoversigt

Status

Rekruttering

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

Positron emission tomography with 18F fluorodeoxyglucose (FDG) is the conventional imaging technique to provide information regarding tissue glucose uptake and has been highly clinically successful. However, it cannot assess downstream metabolism, which may be useful in the diagnosis and assessment of treatment response in a variety of diseases. Patients will also be exposed to ionizing radiation, the amount of exposure can vary depending on the dose of tracer administered, frequency of scans and duration of each scan.

Carbon 13 (13C) magnetic resonance imaging (MRI) is particularly attractive for metabolic imaging because carbon serves as the backbone of nearly all organic molecules in the body. However, the low natural abundance of the 13C isotope at ~1.1% has made in vivo imaging extremely challenging. To improve the MR signal 13C nuclei, probes are synthetically enriched to increase the concentration of the 13C label in a molecule. MRI signal can be further increased by the process of hyperpolarization. At low temperature and high magnetic field, electrons have a very high level of polarization (ie, nearly all the electrons are aligned in the same direction). This high level of polarization can be transferred to 13C-labeled probes, increasing their MRI signals. This transfer of polarization is accomplished by mixing radicals (a source of free electrons) with the 13C-labeled probe(s) to be hyperpolarized and placing the mixture in a polarizer at a magnetic field typically of 3.0-5.0 T and at a low temperature (approximately 1 K). Microwave irradiation is then applied to transfer the polarization from unpaired electrons in a trityl radical to the 13C-labeled probe. The final solution retains a high level of polarization and can be formulated to be at physiologic pH, osmolarity, and temperature for in vivo injection and metabolic investigations.

With this technique, the polarization increases to approximately 30%-40%, an increase of over 10,000 to 100,000-fold, thereby dramatically increasing the MRI signal (Figure 1). The enhanced signal, however, is typically available only for a short period of time (1-2 minutes), as the polarization decays back to its thermal equilibrium level. Therefore, rapid imaging is needed to acquire high signal-to-noise ratio metabolic data with minimal polarization loss and to measure fast metabolic processes.

To date, hyperpolarized imaging technique has been performed in more than 800 healthy volunteers and patients; and in more than 1,200 studies in various clinical conditions.

HYPOTHESIS AND OBJECTIVES:

This proof-of-concept study to demonstrate feasibility and application of 13C hyperpolarized imaging in healthy Singapore residents and patients with cardiovascular/cardiometabolic diseases.

  1. To establish reference ranges in the metabolic products of hyperpolarized 13C-pyruvate (lactate, alanine and bicarbonate) in healthy volunteers and examine repeatability of the 13C hyperpolarized imaging sequences.
  2. To develop the application of 13C hyperpolarized imaging in patients with cardiovascular and cardiometabolic diseases.

Undersøgelsestype

Interventionel

Tilmelding (Anslået)

200

Fase

  • Fase 2

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiekontakt

Studiesteder

      • Singapore, Singapore, 169609
        • Rekruttering
        • National Heart Centre Singapore

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

21 år til 99 år (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ja

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

Healthy Volunteers:

  1. Age 21 years and above
  2. No significant medical co-morbidities (such as chronic kidney disease, diabetes mellitus, heart failure, ischemic heart disease, previous strokes)
  3. No history of cancer
  4. Able and willing to comply with study procedures and provide signed informed consent

Patients with cardiovascular/cardiometabolic diseases:

  1. Age 21 years and above
  2. Physician diagnosed cardiovascular conditions: ischemic heart disease, inherited cardiomyopathies (hypertrophic, dilated or infiltrative cardiomyopathies) and stable heart failure; and/or
  3. Cardiometabolic conditions (such as diabetes on medications, hypertension, central obesity, fatty liver disease)
  4. Able and willing to comply with study procedures and provide signed informed consent

Exclusion Criteria:

  1. Standard contraindications for magnetic resonance procedures (such as implantable medical devices, suspected presence of surgical apparatus or shrapnel, severe claustrophobia)
  2. Unstable medical conditions (such as symptomatic heart failure, unstable hypertension/glucose levels as determined by investigators, symptomatic arrhythmias, angina)
  3. Pregnant or nursing women
  4. Known allergies to pyruvate or any of its components

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Diagnostisk
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Hyperpolarized Pyruvate [13C] Injection

Hyperpolarized 13C-pyruvate is injected intravenously at a dose of 0.43 mL/kg body weight, and at a rate of 5 mL/second followed by a 20 mL saline flush at 5 mL/second when the patient is already in the MRI scanner.

Hyperpolarized 13C-pyruvate is injected intravenously at a dose of 0.43 mL/kg body weight, and at a rate of 5 mL/second followed by a 20 mL saline flush at 5 mL/second when the patient is already in the MRI scanner

Andre navne:
  • Hyperpolariseret kulstof C 13 pyruvat
  • (13C) pyruvat

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Feasibility and reproducibility of Imaging Technique
Tidsramme: 30 - 45 minutes post dose

Feasibility and reproducibility of the imaging technique in healthy volunteers and patients with cardiovascular and/or cardiometabolic diseases

30 - 45 minutes post dose

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Samarbejdspartnere

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

17. oktober 2024

Primær færdiggørelse (Anslået)

31. maj 2028

Studieafslutning (Anslået)

31. maj 2028

Datoer for studieregistrering

Først indsendt

2. oktober 2024

Først indsendt, der opfyldte QC-kriterier

15. oktober 2024

Først opslået (Faktiske)

17. oktober 2024

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

17. november 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

12. november 2026

Sidst verificeret

1. november 2026

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • POLARIC-13

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .