Clinical Evaluation of Conventional and 3D-printed Implant-supported Overdentures Retained With New Attachment Systems (IODs)
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Detaljeret beskrivelse
Undersøgelsestype
Undersøgelsestype
Tilmelding (Anslået)
Tilmelding
Fase
Fase
- Ikke anvendelig
Kontakter og lokationer
Studiesteder
-
-
-
Asyut, Egypten
- Faculty of Dental Medicine, Al-Azhar University, (Assiut Branch)
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
- Barn
- Voksen
- Ældre voksen
Tager imod sunde frivillige
Beskrivelse
Inclusion Criteria:
- Completely edentulous patients
- Non-smokers
- Patients free from intra-oral diseases that may affect implant-overdenture prognosis
- Patients free from systemic conditions that may influence bone resorption or implant success
- Able and willing to comply with study visits and follow-up schedule
Exclusion Criteria:
- Smokers or tobacco users
- Presence of active oral lesions, infections, or mucosal pathology
- Systemic diseases affecting bone metabolism (e.g., uncontrolled diabetes, osteoporosis requiring bisphosphonates)
- History of head and neck radiation
- Severe parafunctional habits (e.g., bruxism)
- Inability to attend follow-up appointments or provide informed consent
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Sundhedstjenesteforskning
- Tildeling: Randomiseret
- Interventionel model: Crossover opgave
- Maskning: Ingen (Åben etiket)
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Eksperimentel: Arm 1: Denture A with Locator ST Participants receive Denture A retained by Locator ST attachments.
Participants receive Denture A retained by Locator ST attachments.
|
Participants receive Denture A, a conventional mandibular implant overdenture, retained by two Locator ST attachments placed in the interforaminal region.
Outcomes include OHIP-19, VAS satisfaction, retention force, attachment wear, periodontal parameters, and denture tooth wear resistance.
|
|
Eksperimentel: Denture A with Locator EMI
Participants receive Denture A retained by two Locator EMI attachments.
Same outcome measures as above, allowing comparison of attachment type influence on patient-reported and clinical outcomes.
|
Participants receive Denture A, a conventional mandibular implant overdenture, retained by two Locator ST attachments placed in the interforaminal region.
Outcomes include OHIP-19, VAS satisfaction, retention force, attachment wear, periodontal parameters, and denture tooth wear resistance.
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Retention Force of Implant Overdentures (IODs)
Tidsramme: Outcome measures were assessed at four clearly defined time points: 1. Baseline (Immediately after overdenture pick up) 2. 3 month follow up 3. 6 month follow up 4. 9 month follow up These time points correspond to the evaluation of implant overdentures
|
Retention force measured using a digital force gauge to quantify the dislodgement force required to remove the overdenture from the implants.
Measurements will be reported in Newtons (N).
|
Outcome measures were assessed at four clearly defined time points: 1. Baseline (Immediately after overdenture pick up) 2. 3 month follow up 3. 6 month follow up 4. 9 month follow up These time points correspond to the evaluation of implant overdentures
|
|
Denture Wear of Implant Overdentures (IODs)
Tidsramme: Wear was evaluated relative to the baseline measurement taken immediately after pick-up, with follow-up assessment 9-month per denture type: 1. 3 month follow up 2. 6 month follow up 3. 9 month follow up
|
Denture wear assessed by measuring surface loss on occlusal surface using digital analysis.
Wear depth recorded in millimeters (mm) at each evaluation point.
|
Wear was evaluated relative to the baseline measurement taken immediately after pick-up, with follow-up assessment 9-month per denture type: 1. 3 month follow up 2. 6 month follow up 3. 9 month follow up
|
|
Peri-implant Soft Tissue Health (Modified Plaque Index and Modified Bleeding Index Scores)
Tidsramme: Assessments performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
|
Peri-implant soft tissue health assessed using the Modified Plaque Index (mPI) and Modified Bleeding Index (mBI). Both indices are ordinal clinical scales scored according to standard peri-implant evaluation criteria: mPI range: 0-3 0 = no plaque 3 = abundant plaque mBI range: 0-3 0 = no bleeding 3 = profuse bleeding Interpretation: Higher scores indicate worse peri-implant soft tissue health. Unit of Measure: Ordinal index scores (mPI, mBI) |
Assessments performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
|
|
Crestal bone level changes
Tidsramme: Radiographic measurements performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
|
Crestal bone levels measured on standardized periapical radiographs taken with a paralleling technique.
Bone level is defined as the distance from the implant shoulder to the first bone-to-implant contact.
|
Radiographic measurements performed over an 18-month total follow-up period, at the following intervals: 1 - Immediately after pick-up (baseline) 2 - 3 months 3 - 6 months 4 - 9 months 5 - 12 months 6 - 15 months 7 - 18 months
|
|
Oral Health-Related Quality of Life (OHIP-19 score)
Tidsramme: OHIP-19 scores recorded three times during each 9-month denture phase: 1 -Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
|
Oral health-related quality of life assessed using the Oral Health Impact Profile-19 (OHIP-19) questionnaire. The OHIP-19 consists of 19 items, each scored on a 5-point ordinal scale from 0 to 4: 0 = never 4 = very often Minimum score: 0 Maximum score: 76 Interpretation: Higher scores indicate worse oral health-related quality of life. |
OHIP-19 scores recorded three times during each 9-month denture phase: 1 -Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
|
|
Patient Satisfaction (Visual Analog Scale Score)
Tidsramme: VAS satisfaction scores recorded three times during each 9-month denture phase: 1 - Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
|
Patient satisfaction with the denture and attachment system measured using a 10-point Visual Analog Scale (VAS). Participants rated their satisfaction on a scale from 0 to 10: 0 = completely dissatisfied 10 = completely satisfied |
VAS satisfaction scores recorded three times during each 9-month denture phase: 1 - Before pick-up 2 - Immediately after pick-up 3 - At 9 months follow up
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Studiestart
Primær færdiggørelse (Anslået)
Primær færdiggørelse
Studieafslutning (Anslået)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- Al-Azhar University, (Assiut B
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .