Effect of High-Flow Humidified Oxygen on Ventilatory Work During the Spontaneous Breathing Trial (OTRAVAIL)
Weaning from mechanical ventilation (MV) accounts for a significant portion of the total MV duration, and failure to extubate or delayed extubation increases complications (particularly Ventilator-Associated Pneumonia (VAP)) and mortality. Standard tests (T-piece, Spontaneous Ventilation with Inspiratory Assistance (SV-IA)) have not demonstrated clear superiority, and the T-piece is still widely used despite its limitations. High-flow oxygen (HFO) may reduce ventilatory work and facilitate secretion clearance; however, there is a lack of physiological data in humans with an endotracheal tube in place. This study aims to address this gap prior to a subsequent clinical evaluation.
An experimental, prospective, single-center, 3-period crossover study with randomized sequence order and single-blind design (primary endpoint assessment and statistical analysis were conducted in a blinded manner).
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Undersøgelsestype
Undersøgelsestype
Tilmelding (Anslået)
Tilmelding
Fase
Fase
- Ikke anvendelig
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
- Voksen
- Ældre voksen
Tager imod sunde frivillige
Beskrivelse
Inclusion Criteria:
- Adult patient, of legal age
- On invasive mechanical ventilation for more than 48 hours
With at least one criterion indicating a high risk of extubation failure:
- Age > 65 years
- Chronic respiratory disease
- Chronic cardiac disease
Capable of undergoing a mechanical ventilation weaning test ("weaning criterion"):
- Respiratory rate < 35 bpm
Adequate oxygenation:
- SpO₂ ≥ 90% with FiO₂ ≤ 40% and PEEP ≤ 8 cm H₂O
- Or PaO₂/FiO₂ ≥ 150 with PEEP ≤ 8 cm H₂O
- Effective cough
- Patient is alert (RASS score -2 to +1), without sedation
- Hemodynamically stable or on the minimum effective dose
- Patient has an invasive arterial pressure catheter for arterial blood sampling
- Informed consent signed by a family member
- Patient is enrolled in or eligible for a social security program
Exclusion Criteria:
- Resuscitation-associated neuromyopathy
- History of neuromuscular disease
- Admission for a neurological condition
- Subjects currently excluded from another study,
- Persons referred to in Articles L1121-5 through L1121-8 of the CSP (corresponding to all protected persons: pregnant women, women in labor, breastfeeding mothers, persons deprived of liberty by judicial or administrative decision, persons receiving psychiatric care pursuant to Articles L. 3212-1 and L. 3213-1 who are not covered by the provisions of Article L. 1121-8, persons admitted to a health or social care facility for purposes other than research, minors, and persons subject to a legal protection order or unable to give informed consent).
- Staff members who report to the principal investigator
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: Randomiseret
- Interventionel model: Crossover opgave
- Maskning: Dobbelt
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Andet: TP/HFO/PSV
T piece follow by HFO follow by PSV
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
Andet: TP/PSV/HFO
T piece follow by PSV follow by HFO
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
Andet: PSV/HFO/TP
PSV follow by HFO follow by T piece
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
Andet: PSV/TP/HFO
PSV follow by T piece follow by HFO
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
Andet: HFO/TP/PSV
HFO follow by T piece follow by PSV
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
Andet: HFO/PSV/TP
HFO follow by PSV follow by TP
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Respiratory work during the weaning test, defined as the energy expended to inhale and exhale a respiratory gas, measured in joules per liter per minute.
Tidsramme: 190 min
|
190 min
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Tidal Volume
Tidsramme: 190 min
|
190 min
|
|
Total Positive End-Expiratory Pressure
Tidsramme: 190 min
|
190 min
|
|
Respiratory Rate
Tidsramme: 190 min
|
190 min
|
|
minute ventilation
Tidsramme: 190 min
|
190 min
|
|
Ratio Respiratory rate/ Tidal volume
Tidsramme: 190 min
|
190 min
|
|
product pressure time
Tidsramme: 190 min
|
190 min
|
|
Occlusion pressure (or P 0.1)
Tidsramme: 190 min
|
190 min
|
|
Percentage of success on the weaning test (predefined criteria)
Tidsramme: 190 min
|
190 min
|
Andre resultatmål
Andre resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Percentage of patients extubated following the series of weaning trials
Tidsramme: 190 min
|
190 min
|
|
Percentage of reintubations within 48 hours after extubation
Tidsramme: 52 hours
|
52 hours
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Datoer for undersøgelser
Studer store datoer
Studiestart (Anslået)
Studiestart
Primær færdiggørelse (Anslået)
Primær færdiggørelse
Studieafslutning (Anslået)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- 38RC25.0307
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
produkt fremstillet i og eksporteret fra U.S.A.
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .