Breast MRI for Early Detection of Breast Cancer in Thuringia
Diagnostic Accuracy of Breast MRI as the Primary Modality for Early Detection of Breast Cancer in Thuringia: A Retrospective Registry-Linked Study
Breast magnetic resonance imaging (MRI) has different diagnostic characteristics from conventional mammography and may detect breast cancers that are difficult to identify using mammography. In a predefined study population in Thuringia, Germany, breast MRI was performed as the primary imaging examination for early detection of breast cancer instead of conventional mammography.
The primary purpose of this study is to assess the quality and performance of the MRI-based breast cancer early detection program. This retrospective diagnostic accuracy study will evaluate the performance of breast MRI using MRI data collected for early breast cancer detection, subsequent diagnostic assessment and histopathological data, and longitudinal population-based cancer registry information.
The primary objective is to determine the sensitivity of breast MRI for detection of invasive breast cancer. Specificity, program sensitivity, interval breast cancer, predictive values, receiver operating characteristic measures, cancer detection and interval cancer rates, diagnostic assessment and biopsy rates, ductal carcinoma in situ, and tumor characteristics will be evaluated as secondary outcomes.
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Undersøgelsestype
Undersøgelsestype
Tilmelding (Faktiske)
Tilmelding
Kontakter og lokationer
Studiesteder
-
-
Thuringia
-
Jena, Thuringia, Tyskland, 07747
- Jena University Hospital, Department of Radiology
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Prøveudtagningsmetode
Studiebefolkning
Women who participated in the original Thuringian breast MRI early detection study, in which breast MRI was used as the protocol-defined primary imaging examination for early detection of breast cancer instead of conventional mammography. All eligible participants from the original MRI early detection cohort will be considered for inclusion in the present retrospective diagnostic accuracy analysis. Diagnostic performance will be assessed using MRI findings, subsequent diagnostic assessment and histopathology, and longitudinal cancer ascertainment including population-based cancer registry data.
Beskrivelse
Inclusion Criteria:
- Breast MRI performed as the protocol-defined primary imaging examination for early detection of breast cancer instead of conventional mammography.
- Evaluable breast MRI examination.
- Adequate reference-standard information to determine breast cancer status.
- A mammogram or ultrasound could not clearly show whether breast cancer has returned. This may be after breast-conserving treatment (surgery and/or radiotherapy) or after breast reconstruction.
- A follow-up breast examination should be carried out every 2 years after the operation.
- There is a familial risk, for example because first-degree relatives already have or have had breast cancer.
- The mammogram cannot be interpreted because of dense breast tissue.
Exclusion Criteria:
- MRI early detection examination not completed or technically non-evaluable.
- Insufficient data to determine the MRI assessment.
- Not a resident of Thuringia
- Bilateral mastectomies
- BIRADS 6
- Missing follow-up
- Examination discontinued
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Observationsmodeller: COHORT
- Tidsperspektiver: RETROSPECTIVE
Antal grupper/kohorter
Kohorter og interventioner
Gruppe / kohorteGruppe / kohorte |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Breast MRI Early Detection Cohort
Women who participated in the original Thuringian breast cancer early detection study and underwent breast MRI as the protocol-defined primary examination for early detection of breast cancer instead of conventional mammography. Diagnostic performance will be evaluated retrospectively using MRI findings, subsequent diagnostic assessment and histopathology, and longitudinal cancer ascertainment. |
Contrast-enhanced breast magnetic resonance imaging performed as the protocol-defined primary imaging examination for early detection of breast cancer instead of conventional mammography. MRI examinations were interpreted according to the assessment criteria specified in the original study protocol. Detailed MRI acquisition and interpretation parameters, including MRI system, field strength, breast coil, imaging sequences, contrast agent, reader characteristics, and assessment categories, will be retrieved from the original study documentation. |
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Sensitivity of Breast MRI for Invasive Breast Cancer
Tidsramme: Index MRI examination through 24 months after the index examination
|
Sensitivity will be calculated as the proportion of participants with invasive breast cancer who had a positive index MRI examination: Sensitivity = true positives / (true positives + false negatives). Invasive breast cancer status will be determined using histopathological verification and longitudinal cancer ascertainment according to the prespecified composite reference standard. Sensitivity will be reported with a two-sided 95% confidence interval. |
Index MRI examination through 24 months after the index examination
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Samarbejdspartnere
Samarbejdspartnere
Efterforskere
Efterforskere
- Studieleder: Ulf Prof. Teichgräber, MD, Friedrich-Schiller-University Jena, Jena University Hospital
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Studiestart
Primær færdiggørelse (Faktiske)
Primær færdiggørelse
Studieafslutning (Faktiske)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- MRI Breast Cancer Thuringia
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .