PSMA-Targeting Dual-Target Radiopharmaceuticals for Prostate Cancer Imaging
A Clinical Study Evaluating the Diagnostic Performance and Safety of PSMA-Targeting Dual-Target Radiopharmaceuticals in Patients With Prostate Cancer
This study will evaluate the diagnostic performance and safety of gallium-68 (68Ga)-labeled dual-target imaging agents in patients with prostate cancer. These investigational agents are designed to target either EphA2 and prostate-specific membrane antigen (PSMA), or ACP3 and PSMA, for positron emission tomography/computed tomography (PET/CT) imaging.
The main aims are to assess how well these imaging agents detect prostate cancer lesions, evaluate their safety, and estimate the radiation doses received by different organs and the body as a whole. The study will also explore their potential use in early diagnosis, determining the extent of cancer spread, and detecting cancer recurrence.
Studieoversigt
Status
Status
Betingelser
Betingelser
Intervention / Behandling
Intervention / Behandling
Undersøgelsestype
Undersøgelsestype
Tilmelding (Anslået)
Tilmelding
Fase
Fase
- Tidlig fase 1
Kontakter og lokationer
Studiesteder
-
-
Jiangsu
-
Suzhou, Jiangsu, Kina, 215000
- The First Affiliated Hospital of Soochow University
-
-
Deltagelseskriterier
Berettigelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- Voluntary provision of written informed consent.
Male, aged 18-80 years.
Pathologically confirmed prostate cancer, including newly diagnosed disease, recurrence after surgery, or metastatic disease.
At least one measurable or evaluable lesion.
Eastern Cooperative Oncology Group (ECOG) performance status of 0-2.
Hematological parameters, liver and kidney function, and electrolyte levels meeting protocol-defined requirements.
Ability to cooperate with and complete PET/CT imaging.
Exclusion Criteria:
- Inability to tolerate or cooperate with PET/CT imaging, for example, due to claustrophobia.
Severe, uncontrolled disease affecting vital organs, including the heart, liver, or kidneys.
Any other condition that, in the investigator's judgment, makes the participant unsuitable for participation in the study.
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Diagnostisk
- Tildeling: Ikke-randomiseret
- Interventionel model: Enkelt gruppeopgave
- Maskning: Ingen (Åben etiket)
Antal våben
Våben og indgreb
Deltagergruppe / ArmDeltagergruppe / Arm |
Intervention / BehandlingIntervention / Behandling |
|---|---|
|
Eksperimentel: 68Ga-Labeled EphA2/PSMA Dual-Target PET/CT Imaging
Patients with prostate cancer will receive an intravenous injection of a 68Ga-labeled EphA2/PSMA dual-target radiotracer and undergo PET/CT imaging. Diagnostic performance, safety, biodistribution, and radiation dosimetry will be evaluated. Imaging findings will be compared with [18F]FDG PET/CT or single-target PSMA PET/CT findings according to the study protocol. |
An investigational gallium-68-labeled radiotracer targeting both EphA2 and PSMA. The radiotracer will be administered intravenously to patients with prostate cancer, followed by PET/CT imaging to evaluate diagnostic performance, biodistribution, and radiation dosimetry. Safety will be assessed by monitoring adverse events. |
|
Eksperimentel: 68Ga-Labeled ACP3/PSMA Dual-Target PET/CT Imaging
Patients with prostate cancer will receive an intravenous injection of a 68Ga-labeled ACP3/PSMA dual-target radiotracer and undergo PET/CT imaging. Diagnostic performance, safety, biodistribution, and radiation dosimetry will be evaluated. Imaging findings will be compared with [18F]FDG PET/CT or single-target PSMA PET/CT findings according to the study protocol. |
An investigational gallium-68-labeled radiotracer targeting both ACP3 and PSMA. The radiotracer will be administered intravenously to patients with prostate cancer, followed by PET/CT imaging to evaluate diagnostic performance, biodistribution, and radiation dosimetry. Safety will be assessed by monitoring adverse events. |
Hvad måler undersøgelsen?
Primære resultatmål
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Safety
Tidsramme: From radiotracer injection to 24 hours post-injection
|
Participants who experience at least one new or worsening adverse event during the observation period will be counted. Each participant will be counted once, regardless of the number of events. |
From radiotracer injection to 24 hours post-injection
|
|
Diagnostic efficacy
Tidsramme: Through study completion, an average of 6 months
|
At the patient level, the detection rate will be calculated as the percentage of participants with an evaluable [68Ga]Ga-Dual-Target Radiotracer PET/CT scan showing at least one PET-positive tumor lesion. The number of PET-positive tumor lesions per participant will also be recorded. At the lesion level, tracer uptake will be quantified using the maximum standardized uptake value (SUVmax), and lesion contrast will be assessed using the tumor-to-background ratio (TBR). |
Through study completion, an average of 6 months
|
Sekundære resultatmål
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Dosimetry
Tidsramme: Through study completion, an average of 6 months
|
The absorbed dose from [68Ga]Ga-Dual-Target Radiotracer will be estimated separately for each target organ and expressed in milligrays per megabecquerel of administered activity (mGy/MBq). |
Through study completion, an average of 6 months
|
Samarbejdspartnere og efterforskere
Sponsor
Sponsor
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Studiestart
Primær færdiggørelse (Anslået)
Primær færdiggørelse
Studieafslutning (Anslået)
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Først opslået
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering sendt
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
Andre undersøgelses-id-numre
- 2026-68Ga-psma daul-target
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .