Mesh Ablator Versus Cryoballoon Pulmonary Vein Ablation of Symptomatic Paroxysmal Atrial Fibrillation (MACPAF)
HD Mesh Ablator Versus Cryoballoon Pulmonary Vein Ablation of Symptomatic Paroxysmal Atrial Fibrillation - Efficiency and Safety of PV Ablation Systems
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Detaillierte Beschreibung
Primary objective:
• Efficacy of pulmonary vein isolation defined by achieving an exit block for all pulmonary veins per patient.
Secondary objectives:
- Detecting (silent) cerebral thromboembolism using neuro(psychological) tests and brain MRI prior and within 2 days after PV ablation.
- Detecting (silent) cerebral thromboembolism using neuro(psychological) tests and brain MRI within 6 months after PV ablation.
- Determination of spontaneous recurrence rate of atrial fibrillation using a subcutaneously implanted loop recorder (Reveal XT®).
- Characterization of non-neurological major complications (death, atrial-esophageal fistula, pulmonary vein stenosis, pericardial tamponade)
- Rate of iatrogenic interatrial septal defects after transseptal puncture for PV ablation.
Studientyp
Studientyp
Einschreibung (Voraussichtlich)
Einschreibung
Phase
Phase
- Phase 4
Kontakte und Standorte
Studienorte
-
-
-
Berlin, Deutschland, 12200
- Charité, University Medicine Berlin, Campus Benjamin Franklin, Hindenburgdamm 30
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Patients with ECG-documented symptomatic paroxysmal atrial fibrillation and at least one ineffective antiarrhythmic drug treatment
Exclusion Criteria:
- Previous ablation procedure for atrial fibrillation or cardiac surgery within 3 months
- Left atrial diameter > 50mm or ejection fraction < 35%
- Instable coronary artery disease or clinically relevant cardiac valve insufficiency
- Hyperthyroidism, pregnancy or lactation; coumadin or heparin intolerance
- Concomitant disease with expected lifespan < 2 years
- Contraindications for MRI or acute cerebral infarction detected by brain MRI immediately (< 24 hours) before catheter ablation.
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Single
Anzahl der Arme
Waffen und Interventionen
Teilnehmergruppe / ArmTeilnehmergruppe / Arm |
Intervention / BehandlungIntervention / Behandlung |
|---|---|
|
Aktiver Komparator: Arctic Front® catheter
|
Pulmonary vein ablation in patients with symptomatic paroxysmal atrial fibrillation using the Arctic Front® catheter versus the HD Mesh Ablator® catheter
|
|
Aktiver Komparator: HD Mesh Ablator® catheter
|
Pulmonary vein ablation in patients with symptomatic paroxysmal atrial fibrillation using the Arctic Front® catheter versus the HD Mesh Ablator® catheter
|
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Zeitfenster |
|---|---|
|
Efficacy of pulmonary vein isolation defined by achieving an exit block for all pulmonary veins per patient
Zeitfenster: During ablation procedure
|
During ablation procedure
|
Sekundäre Ergebnismessungen
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Zeitfenster |
|---|---|
|
Detecting (silent) cerebral thromboembolism using neuro(psychological) tests and brain MRI
Zeitfenster: within 2 days after catheter ablation
|
within 2 days after catheter ablation
|
|
Detecting (silent) cerebral thromboembolism using neuro(psychological) tests and brain MRI
Zeitfenster: 6 months after catheter ablation
|
6 months after catheter ablation
|
|
Determination of spontaneous recurrence rate of atrial fibrillation using a subcutaneously implanted loop recorder (Reveal XT®)
Zeitfenster: 1 year after catheter ablation
|
1 year after catheter ablation
|
|
Characterization of non-neurologic major complications (death, atrial-esophageal fistula, pulmonary vein stenosis, pericardial tamponade)
Zeitfenster: within 1 month after catheter ablation
|
within 1 month after catheter ablation
|
|
Rate of iatrogenic interatrial septal defects after transseptal puncture for left-sided atrial catheter ablation
Zeitfenster: 1 year after catheter ablation
|
1 year after catheter ablation
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Mitarbeiter
Mitarbeiter
Ermittler
Ermittler
- Hauptermittler: Alexander Schirdewan, MD, Department of Cardiology, Charité - University Medicine Berlin, Germany.
- Hauptermittler: Jochen B Fiebach, MD, Center for Stroke Research Berlin
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Herm J, Schirdewan A, Koch L, Wutzler A, Fiebach JB, Endres M, Kopp UA, Haeusler KG. Impact of atrial fibrillation burden on cognitive function after left atrial ablation - Results of the MACPAF study. J Clin Neurosci. 2020 Mar;73:168-172. doi: 10.1016/j.jocn.2019.12.030. Epub 2020 Jan 25.
- Schirdewan A, Herm J, Roser M, Landmesser U, Endres M, Koch L, Haeusler KG. Loop Recorder Detected High Rate of Atrial Fibrillation Recurrence after a Single Balloon- or Basket-Based Ablation of Paroxysmal Atrial Fibrillation: Results of the MACPAF Study. Front Cardiovasc Med. 2017 Feb 13;4:4. doi: 10.3389/fcvm.2017.00004. eCollection 2017.
- Herm J, Fiebach JB, Koch L, Kopp UA, Kunze C, Wollboldt C, Brunecker P, Schultheiss HP, Schirdewan A, Endres M, Haeusler KG. Neuropsychological effects of MRI-detected brain lesions after left atrial catheter ablation for atrial fibrillation: long-term results of the MACPAF study. Circ Arrhythm Electrophysiol. 2013 Oct;6(5):843-50. doi: 10.1161/CIRCEP.113.000174. Epub 2013 Aug 29.
- Haeusler KG, Koch L, Herm J, Kopp UA, Heuschmann PU, Endres M, Schultheiss HP, Schirdewan A, Fiebach JB. 3 Tesla MRI-detected brain lesions after pulmonary vein isolation for atrial fibrillation: results of the MACPAF study. J Cardiovasc Electrophysiol. 2013 Jan;24(1):14-21. doi: 10.1111/j.1540-8167.2012.02420.x. Epub 2012 Aug 22.
- Koch L, Haeusler KG, Herm J, Safak E, Fischer R, Malzahn U, Werncke T, Heuschmann PU, Endres M, Fiebach JB, Schultheiss HP, Schirdewan A. Mesh ablator vs. cryoballoon pulmonary vein ablation of symptomatic paroxysmal atrial fibrillation: results of the MACPAF study. Europace. 2012 Oct;14(10):1441-9. doi: 10.1093/europace/eus084. Epub 2012 Apr 20.
- Haeusler KG, Koch L, Ueberreiter J, Coban N, Safak E, Kunze C, Villringer K, Endres M, Schultheiss HP, Fiebach JB, Schirdewan A. Safety and reliability of the insertable Reveal XT recorder in patients undergoing 3 Tesla brain magnetic resonance imaging. Heart Rhythm. 2011 Mar;8(3):373-6. doi: 10.1016/j.hrthm.2010.11.008. Epub 2010 Nov 9.
- Haeusler KG, Koch L, Ueberreiter J, Endres M, Schultheiss HP, Heuschmann PU, Schirdewan A, Fiebach JB. Stroke risk associated with balloon based catheter ablation for atrial fibrillation: Rationale and design of the MACPAF Study. BMC Neurol. 2010 Jul 21;10:63. doi: 10.1186/1471-2377-10-63.
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Schätzen)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Schätzen)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- MACPAF
- 4-087-08 (Andere Kennung: ethic's committee Charité Berlin)
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .