Plating of Distal Femur Fractures by Far Cortical Locking Using MotionLoc Screws
MotionLoc Study: Healing of Distal Femur Fractures Stabilized With a Flexible Plating Construct Using MotionLoc Screws
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Detaillierte Beschreibung
Rigid locked plating constructs can suppress fracture healing, particularly at the near cortex adjacent to the plate where interfragmentary motion is minimal. Dynamic fixation with Far Cortical Locking (FCL) screws reduces construct stiffness and induces axial interfragmentary motion to stimulate symmetric callus formation and healing. Two versions of FCL screws are commercially available, but the clinical durability of this novel concept has not been documented to date. This prospective observational study documented our early clinical experience with MotionLoc® FCL screws for stabilization of distal femur fractures to assess their durability and potential complications.
Thirty-two consecutive patients with 33 distal femur fractures (AO/OTA types 33-A and 33-C) were prospectively enrolled at three trauma centers. Fractures were stabilized by plate osteosynthesis with MotionLoc® FCL screws without supplemental bone graft or bone morphogenic proteins. Thirty patients with 31 fractures were available for follow-up until union or revision. Follow-up visits at 6, 12, and 24 weeks comprised functional and radiographic assessment of implant fixation and fracture healing, including computed tomography scans at week 12. The primary endpoint was fracture healing in absence of complications and revision.
There was no incidence of implant breakage or diaphyseal fixation failure. Thirty of 31 fractures healed within 15.6 ± 6.2 weeks, as evident by bridging callus and pain-free load bearing. There were two revisions, one at 5 days post surgery to correct a mal-rotation, and one at 6 months post surgery to revise a non-union. Periosteal callus distribution at week 6 was symmetrical, with similar amounts of callus at the medial cortex (35%) anterior cortex (30%) and posterior cortex (35%). In 23 fractures (74%), callus formation extended to the lateral cortex under the plate.
Absence of hardware and fixation failure suggests that dynamic plating of distal femur fractures with FCL screws provides safe and effective fixation. Moreover, the amount and symmetric distribution of periosteal callus suggests that dynamic fixation with FCL screws may promote increased fracture healing over standard locked plating. However, this hypothesis on the stimulatory effect of dynamic fixation on fracture healing requires investigation in a future randomized control trial.
Studientyp
Studientyp
Einschreibung (Voraussichtlich)
Einschreibung
Kontakte und Standorte
Studienorte
-
-
Oregon
-
Portland, Oregon, Vereinigte Staaten, 97232
- Legacy Health System
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Probenahmeverfahren
Studienpopulation
Beschreibung
Inclusion Criteria:
- Patients with distal femur fracture (AO/OTA Type 33A and 33C)
- Patients 17 years of age and over.
- Patients able to be operated on by selected surgeons at the participating centers.
Exclusion Criteria:
- Pregnancy
- Patients who are enrolled in an investigational treatment trial.
- Patients who are not expected to survive the follow-up period.
- Considered an inappropriate participant by the study physician.
- Revision surgery
- Patients currently incarcerated or awaiting incarceration.
- Severe spinal injury with neurological deficit resulting in paralysis.
- Fracture fixed more then 28 days after injury.
- Acute or chronic local or systemic infections
- Periprosthetic fractures
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
Anzahl der Gruppen / Kohorten
Kohorten und Interventionen
Gruppe / KohorteGruppe / Kohorte |
|---|
|
Femur Fractures
Patients with Distal Femur Fractures
|
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Frakturheilung
Zeitfenster: 6, 12 und 24 Wochen nach der Operation
|
Frakturheilung wird klinisch durch die Fähigkeit zur schmerzfreien Gewichtsbelastung und röntgenologisch durch Kallusbildung und -überbrückung definiert.
|
6, 12 und 24 Wochen nach der Operation
|
Sekundäre Ergebnismessungen
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Periostkallusgröße
Zeitfenster: 6, 12, 24 Wochen nach der Operation
|
Die Größe des Periostkallus wird an den vorderen, hinteren und medialen Aspekten auf Röntgenbildern unter Verwendung eines validierten Berechnungsalgorithmus beurteilt.
|
6, 12, 24 Wochen nach der Operation
|
|
Brückenkallus aus CT
Zeitfenster: 12 Wochen nach der Operation
|
Querschnittsbildanalyse, unterstützt durch 3-D-Rendering, um knöcherne Überbrückungen an den vorderen, hinteren und seitlichen Aspekten des Femurs zu erkennen.
|
12 Wochen nach der Operation
|
|
Fixierungsfehler
Zeitfenster: 24 Wochen nach der Operation
|
12 und 24 Wochen nach der Operation im Hinblick auf den Verlust der Ausrichtung beurteilt
|
24 Wochen nach der Operation
|
|
Hardwarefehler
Zeitfenster: 6, 12, 24 Wochen nach der Operation
|
Bruch der Schraube oder Platte
|
6, 12, 24 Wochen nach der Operation
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Mitarbeiter
Mitarbeiter
Ermittler
Ermittler
- Hauptermittler: Michael Bottlang, PhD, Legacy Biomechanics Laboratory
- Studienstuhl: Steven Madey, MD, Legacy Health System
Publikationen und hilfreiche Links
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Schätzen)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Schätzen)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- MotionLoc Screw
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .