Comparison Study of Non-invasive Measurement of Blood Pressure and Cardiac Output During Stress Echocardiography
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Detaillierte Beschreibung
The HeartBeat system combines an FDA/CE approved watch-like Pulse Oximeter for acquiring the data and an android software application that serves as the Hemodynamic calculator. The application performs POST-PROCESSING of the PhotoPlethismoGraphic (PPG) signal (Normally the PPG signal in Pulse Oximeters is used only to compute heart rate and SpO2). The raw data is transferred from the watch oximeter to the smartphone using a standard Bluetooth protocol.
The Post-processing uses wavelet signal processing to estimate and display certain Hemodynamic parameters like Blood Pressure (BP) and Cardiac Output (CO) in a continuous and graphical way on a standard Android device. In addition to the standard heart rate and SpO2, the application displays the measured PPG signal and estimated continues BP and CO.
HeartBeat is the only device that can non-invasively estimate Continuous BP and its Cardiac Output component and the resistance component in a mobile wearable device. Differentiating between these 2 components can play a major role in helping the doctor to understand the effect of cardiovascular medications and Lifestyle interventions.
The trial will compare blood pressure and cardiac output parameters measured during Stress Echocardiography using an echo cardiograph and standard sphygmomanometer to the parameters generated by the application.
Trial goals
- Feasibility tests for the HeartBeat application as a tool for monitoring BP and CO changes over time
- Compare BP and CO parameters generated by the applications to the ones measured by standard non-invasive equipment during a Stress Echocardiography
- Calculate additional parameters such as stroke volume, systematic vascular resistance and cardiac index
Studientyp
Studientyp
Einschreibung (Voraussichtlich)
Einschreibung
Kontakte und Standorte
Studienorte
-
-
-
Kfar Saba, Israel, 4428164
- Meir health center
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Probenahmeverfahren
Studienpopulation
Beschreibung
Inclusion Criteria:
- Patients referred to an Stress Echocardiography test for cardiac diagnostics
- Male and Female
- Between 18 to 90 years old
Exclusion Criteria:
- Under the age of 18 or over 90 years old
- Patients in Shock
- Patients with Moderate or Severe valvular disease
- Patients with severe sepsis
- Inadequate jurisprudence patients
- Patients supported by Amines
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Cardiac Output
Zeitfenster: Change from Baseline in Cardiac Output at 30 minutes
|
Measurement of Cardiac Output at the beginning and the end of the test (30 minutes)
|
Change from Baseline in Cardiac Output at 30 minutes
|
Sekundäre Ergebnismessungen
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Blood Pressure
Zeitfenster: Change from Baseline in Systolic and Diastolic blood pressure at 30 minutes
|
Change from Baseline in Systolic and Diastolic blood pressure at 30 minutes
|
|
|
Heart rate
Zeitfenster: Change from Baseline in heart rate at 30 minutes
|
Measurement of Systolic and Diastolic blood pressure at the beginning and the end of the test
|
Change from Baseline in heart rate at 30 minutes
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Ermittler
Ermittler
- Hauptermittler: Yoram Neuman, MD, Meir Health Facility
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn
Studienbeginn
Primärer Abschluss (Voraussichtlich)
Primärer Abschluss
Studienabschluss (Voraussichtlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Schätzen)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- HeartBeat_V2.0_SE
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Niedriges Herzzeitvolumen
-
NCT00994825AbgeschlossenLow-Cardiac-Output-Syndrom
-
NCT02025621AbgeschlossenKoronararterien-Bypass-Operation | Low-Cardiac-Output-Syndrom | Mitralklappenchirurgie
-
NCT00695929AbgeschlossenLow-Cardiac-Output-Syndrom | Angeborene Herz-Kreislauf-Defekte
-
NCT06355882RekrutierungLow-Cardiac-Output-Syndrom
-
NCT00549107Unbekannt
-
NCT04045340AbgeschlossenLow-Cardiac-Output-Syndrom | Mitralklappenerkrankung
-
NCT04698005RekrutierungKetose | Akute Herzinsuffizienz | Hämodynamische Instabilität | Low-Cardiac-Output-Syndrom
-
NCT04643509RekrutierungChirurgie | Schock, kardiogen | Output, Low Cardiac
-
NCT01576094AbgeschlossenLow-Cardiac-Output-Syndrom
Klinische Studien zur Pulse Oximeter CMS50FW (Contec Medical)
-
NCT05771129Rekrutierung
-
NCT02061254AbgeschlossenLymphödem | Venöse Insuffizienz