Clinical Features and Airways Inflammation in Never Smokers and Smokers With COPD
Airway Inflammatory Profile and Clinical Presentation of COPD: A Comparison Between Never Smokers and Smokers
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Detaillierte Beschreibung
Studientyp
Studientyp
Einschreibung (Tatsächlich)
Einschreibung
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Probenahmeverfahren
Studienpopulation
Beschreibung
Inclusion Criteria:
- Subjects with COPD, according to GOLD criteria (smokers and never smokers). Moreover, inhaled short-acting β2-agonists were stopped at least 8h before the test and inhaled long-acting β2-agonist were stopped at least 48h before the test.
- Healthy control subjects : never smokers with normal spirometry and did not have a history of lung disease or chronic respiratory symptoms.
Exclusion Criteria:
- COPD patients were excluded from the study if they had an exacerbation, a respiratory tract infection or if they used a systemic form of corticosteroid preparation (oral or intravenous injection therapy) or antibiotics within the two months prior to the study entry. Patients with other respiratory disorder like pneumonia, pulmonary emboli, congestive heart failure, lung cancer or tuberculosis were also excluded.
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Beobachtungsmodelle: Fallkontrolle
- Zeitperspektiven: Retrospektive
Anzahl der Gruppen / Kohorten
Kohorten und Interventionen
Gruppe / KohorteGruppe / Kohorte |
Intervention / BehandlungIntervention / Behandlung |
|---|---|
|
Healthy subjects
Healthy non-smoking subjects were never smokers with normal spirometry and did not have a history of lung disease or chronic respiratory symptoms. Information about respiratory symptoms and comorbidities were collected. Healthy subjects underwent pulmonary function tests (Spirometry). Induced sputum was collected to determine total and differential inflammatory cells counts as well as inflammatory mediators (Interleukin-8 and tumor necrosis factor-alpha). |
Induced sputum was collected and analysed in the three arms (Healthy subjects, Never smokers with COPD and smokers with COPD) The volume of the sputum sample, was treated with an equal volume of 0.1% dithiothreitol. The samples were then vortexed and placed in a shaking water bath at 37°C for 15 min to ensure complete homogeneisation. The suspensions were centrifuged at 400× g and the sputum supernatant stored at -80°C until cytokines analysis. The cell pellet was resuspended in 0.5% bovine serum albumin in phosphate buffered saline and cytospin were made by putting 100 µL of the cell suspension in the funnels. Slides for differential cell counts were stained with May-Grünwald Giemsa. All the subjects underwent pulmonary function tests (Healthy subjects, Never smokers with COPD and smokers with COPD). Pulmonary function parameters were measured using a portable spirometer (Easy One ndd. Medizintechnik; Zurich, Switzerland) according to the ATS criteria (American Thoracic Society). Reversibility test was performed 15 min after inhalation of 400 µg of Salbutamol (Ventolin, GlaxoSmithKline, Middlesex, UK). All spirometry data were graded for quality and only tests that met high quality scores were used for the final analysis.
Andere Namen:
IL-8 and TNF-α were measured in the sputum supernatant of all the subjects (Healthy subjects, Never smokers with COPD and smokers with COPD). Commercially available kits were used to detect IL-8 (Human IL-8 Immuno-Biological Laboratories ELISA Kit) and TNF-α (Human TNF-alpha Sigma-Aldrich ELISA Kit) concentrations in the sputum supernatants. The absorbance was measured at 450 nm. The lower limits detection were 2 pg/mL for IL-8 and 5 pg/mL for TNF-α. The intra assay coefficients of variability were 8.7% for IL-8 and 7.7% for TNF- α.
Andere Namen:
|
|
COPD Never smokers
Never smokers referred to subjects who had never smoked Airflow limitation in COPD was defined as a post-bronchodilator forced expiratory volume in 1 second (FEV1) to forced vital capacity (FVC) ratio <70% and FEV1 reversibility of <12% and 200 mL from baseline values after inhalation of 400 µg of Salbutamol. Information about respiratory symptoms and comorbidities were collected. Never smoking subjects with COPD underwent pulmonary function tests (Spirometry). Induced sputum was collected to determine total and differential inflammatory cells counts as well as inflammatory mediators (Interleukin-8 and tumor necrosis factor-alpha). |
Induced sputum was collected and analysed in the three arms (Healthy subjects, Never smokers with COPD and smokers with COPD) The volume of the sputum sample, was treated with an equal volume of 0.1% dithiothreitol. The samples were then vortexed and placed in a shaking water bath at 37°C for 15 min to ensure complete homogeneisation. The suspensions were centrifuged at 400× g and the sputum supernatant stored at -80°C until cytokines analysis. The cell pellet was resuspended in 0.5% bovine serum albumin in phosphate buffered saline and cytospin were made by putting 100 µL of the cell suspension in the funnels. Slides for differential cell counts were stained with May-Grünwald Giemsa. All the subjects underwent pulmonary function tests (Healthy subjects, Never smokers with COPD and smokers with COPD). Pulmonary function parameters were measured using a portable spirometer (Easy One ndd. Medizintechnik; Zurich, Switzerland) according to the ATS criteria (American Thoracic Society). Reversibility test was performed 15 min after inhalation of 400 µg of Salbutamol (Ventolin, GlaxoSmithKline, Middlesex, UK). All spirometry data were graded for quality and only tests that met high quality scores were used for the final analysis.
Andere Namen:
IL-8 and TNF-α were measured in the sputum supernatant of all the subjects (Healthy subjects, Never smokers with COPD and smokers with COPD). Commercially available kits were used to detect IL-8 (Human IL-8 Immuno-Biological Laboratories ELISA Kit) and TNF-α (Human TNF-alpha Sigma-Aldrich ELISA Kit) concentrations in the sputum supernatants. The absorbance was measured at 450 nm. The lower limits detection were 2 pg/mL for IL-8 and 5 pg/mL for TNF-α. The intra assay coefficients of variability were 8.7% for IL-8 and 7.7% for TNF- α.
Andere Namen:
|
|
COPD Smokers
Smokers were defined as persons who had smoked > 20 packs of cigarettes in a lifetime and who continue smoking every day. Airflow limitation in COPD was defined as a post-bronchodilator forced expiratory volume in 1 second (FEV1) to forced vital capacity (FVC) ratio <70% and FEV1 reversibility of <12% and 200 mL from baseline values after inhalation of 400 µg of Salbutamol. Information about respiratory symptoms and comorbidities were collected. Smoking subjects with COPD underwent pulmonary function tests (Spirometry). Induced sputum was collected to determine total and differential inflammatory cells counts as well as inflammatory mediators (Interleukin-8 and tumor necrosis factor-alpha). |
Induced sputum was collected and analysed in the three arms (Healthy subjects, Never smokers with COPD and smokers with COPD) The volume of the sputum sample, was treated with an equal volume of 0.1% dithiothreitol. The samples were then vortexed and placed in a shaking water bath at 37°C for 15 min to ensure complete homogeneisation. The suspensions were centrifuged at 400× g and the sputum supernatant stored at -80°C until cytokines analysis. The cell pellet was resuspended in 0.5% bovine serum albumin in phosphate buffered saline and cytospin were made by putting 100 µL of the cell suspension in the funnels. Slides for differential cell counts were stained with May-Grünwald Giemsa. All the subjects underwent pulmonary function tests (Healthy subjects, Never smokers with COPD and smokers with COPD). Pulmonary function parameters were measured using a portable spirometer (Easy One ndd. Medizintechnik; Zurich, Switzerland) according to the ATS criteria (American Thoracic Society). Reversibility test was performed 15 min after inhalation of 400 µg of Salbutamol (Ventolin, GlaxoSmithKline, Middlesex, UK). All spirometry data were graded for quality and only tests that met high quality scores were used for the final analysis.
Andere Namen:
IL-8 and TNF-α were measured in the sputum supernatant of all the subjects (Healthy subjects, Never smokers with COPD and smokers with COPD). Commercially available kits were used to detect IL-8 (Human IL-8 Immuno-Biological Laboratories ELISA Kit) and TNF-α (Human TNF-alpha Sigma-Aldrich ELISA Kit) concentrations in the sputum supernatants. The absorbance was measured at 450 nm. The lower limits detection were 2 pg/mL for IL-8 and 5 pg/mL for TNF-α. The intra assay coefficients of variability were 8.7% for IL-8 and 7.7% for TNF- α.
Andere Namen:
|
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Weight measurement
Zeitfenster: 6 months
|
Weight was measured in kilograms for all the participants.
|
6 months
|
|
Height measurement
Zeitfenster: 6 months
|
Height was measured in meters for all the participants.
|
6 months
|
|
Forced vital capacity (FVC)
Zeitfenster: 6 months
|
FVC was measured using a portable spirometer (Easy One ndd.
Medizintechnik; Zurich, Switzerland) according to the American Thoracic Society criteria.
|
6 months
|
|
Forced expiratory volume in one second (FEV1)
Zeitfenster: 6 months
|
FEV1 was measured using a portable spirometer (Easy One ndd.
Medizintechnik; Zurich, Switzerland) according to the American Thoracic Society criteria.
|
6 months
|
|
Sputum induction and collection
Zeitfenster: 6 months
|
Sputum induction was conducted by inhalation of nebulised sterile hypertonic saline solution followed by coughing and expectoration of airway secretions.
For nebulisation, an ultrasound nebulizer was used for 5-20 min to provide an adequate amount of sample.
The subject is asked to cough and expectorate at 5 min intervals.
|
6 months
|
Sekundäre Ergebnismessungen
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
BMI determination
Zeitfenster: 6 months
|
Weight and height values were combined to report BMI in kg/m2
|
6 months
|
|
Tiffeneau ratio (FEV1/FVC)
Zeitfenster: 6 months
|
The calculation of FEV1/FVC allows the identification of obstructive ventilatory defect.
A FEV1/FVC < 70 % where FEV1 is reduced more than FVC signifies an obstructive defect.
|
6 months
|
|
Sputum cell counts
Zeitfenster: 1 month
|
Four hundred non-squamous cells were counted by two technicians and the mean of the two scores was expressed as percentage of the total cell count.
Sputum samples containing >20% of squamous cells and/or with cell viability <70% were excluded from analysis.
|
1 month
|
|
Sputum supernatant analyses
Zeitfenster: 3 months
|
IL-8 and TNF-α sputum supernatant concentrations were measured in the sputum supernatant of the three studied groups using ELISA test.
|
3 months
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Ermittler
Ermittler
- Studienleiter: Zouhair Tabka, MD PhD, Faculty of Medicine of Sousse
- Hauptermittler: Amina Mrizak, MSc, Faculty of Medicine of Sousse
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- COPDNS
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Beschreibung des IPD-Plans
IPD-Sharing-Zeitrahmen
Art der unterstützenden IPD-Freigabeinformationen
- Studienprotokoll
- Klinischer Studienbericht (CSR)
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Produkt, das in den USA hergestellt und aus den USA exportiert wird
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Analysis of induced sputum
-
NCT05845112AbgeschlossenTuberkulose | Diagnose