Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Hämodynamik und autonome und kognitive Leistung nach Carotis-Revaskularisationsverfahren (BAROX)

10. November 2026 aktualisiert von: Daniela Mazzaccaro, IRCCS Policlinico S. Donato

Einfluss von Karotis-Endarterektomie und Stenting auf Hämodynamik, Fluid-Struktur-Interaktion, autonome Modulation und kognitive Gehirnfunktion

Carotid revascularization procedures are performed for more than 87% of cases in patients with asymptomatic internal carotid stenosis (ICS), who are assumed to have a life expectancy of at least 5 years. Hence, the investigators aim to compare carotid artery stenting (CAS) with carotid endarterectomy (CEA) in terms of long-term prognostic endpoints in patients with uneventful perioperative course. CEA and CAS, as a consequence of either surgical trauma or mechanical stimuli related to the compliance mismatch between the stented segment and the native artery, may perturb carotid baroreceptors function causing an impairment of cardiovascular autonomic control. Also, CEA and CAS result in different postoperative geometric features of carotid arteries that entail relevant modifications of rheological parameters, that may be associated with the risk of local complications. Finally, long-term and sustained cognitive benefits after CAS as compared to CEA are yet to be demonstrated.

Studienübersicht

Status

Abgeschlossen

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

Hypothesis and Significance: Late clinical outcome and prognosis after CAS may be inferior to that after CEA in terms of autonomic modulation, hemodynamic remodeling, and cognitive function.

Specific Aim: 1) To compare the impact of CEA and CAS on long-term post-operative baroreceptor function and on cognitive brain function, and analyze their influence on clinical outcome. The specific goal is to assess the potential correlation between post-operative autonomic and cognitive function. 2) To assess the solicitation on the carotid wall due to CAS as compared to CEA through structural analysis and mechanical modeling. The specific goal is to assess the potential correlation between stenting, wall damage, baroceptor impairment, and late neurological sequelae. 3) To assess the post-operative carotid hemodynamics combining medical image analysis, clinical data, and computer simulations. The specific goal aims at correlating both local (e.g., wall stress stress) and global phenomena (controlateral flow, arterial stiffening) with baroreflex function and post-operative neurological outcomes.

Experimental Design Aim 1: A computerized method requiring small operator interaction will be used to assess indices of autonomic sympathovagal balance directed to the sinoatrial node, sympathetic vasomotor modulation, and baroreflex gain, all from spontaneous beat-by-beat variations of the R-R interval and systolic arterial pressure (SAP) variability, considering only sinus rhythm conditions. After electrode and sensor positioning, patients will be maintained for 10 minute in resting supine position, necessary for stabilization, subsequently blood pressure waveforms, electrocardiogram and respiratory activity will be continuously recorded during a nominal 5-minute baseline and then for subsequent 5-minute period of active standing.

Cardiovascular signals will be acquired by a 4 channel digital polygraph. The electrocardiogram will be recorded with two electrodes placed on the patient's chest, breathing pattern will be recorded by a piezoelectric belt and finger arterial blood pressure will be continuously monitored by a CNAP 500 HD continuous noninvasive hemodynamics monitor (CNSystems Medizintechnik AG, Austria). As described previously, (8) a series of indexes indirectly reflecting autonomic cardiovascular modulation will be derived from the spectral analysis of R-R interval and SAP variability. Postoperative cardiovascular autonomic control will be correlated to clinical outcome and measures of cognitive performance. Enrolled patients will be submitted to Mini-Mental State Examination for general cognitive impairment screening. Cognitive P300 evoked potentials will be then recorded, before and after treatment, with Ag/AgCl electrodes with a Brain Vision Recorder (Brain Products GmbH, Gilching, Germany). P300 evoked potentials will be generated after a binaurally presented tone discrimination paradigm (odd-ball paradigm) with frequent (80%) tones of 1000 Hz and rare (20%) target tones of 2000 Hz at 75 dB HL. Filter bandpass will be 0.01 to 30 Hz. Active electrodes will be placed at Cz (vertex) and Fz (frontal), respectively, and referenced to linked earlobe A1/2 electrodes (10/20 international system). During the paradigm, the patients will be instructed to keep a running mental count of the rare 2000-Hz target tones. To verify attention, P300 recordings with a discrepancy of>10% between the actual number of stimuli and the number counted by the patients will be rejected and repeated. P300 evoked potential recording will result in a stable sequence of positive and negative peaks. Latencies in milliseconds (ms) of the cognitive P300 peak will be assessed. To confirm reproducibility, two sets of P300 measurements will be recorded for all patients.

Experimental Design Aim 2: The computer-based simulation of CAS is performed exploiting a computational framework, which can be used to analyze both stent apposition and vessel wall stress in a virtual manner. The framework accounts for two main parts: the vessel model and stent model. Preoperative and postoperative medical images (including high resolution Contrast Enhanced (CE)-MRI and Computed Tomography Angiography (CTA)) will represent the input to build a patient specific carotid model. The 3D lumen profile of the vessel is reconstructed through the segmentation of DICOM image stack using tools like ITK-SNAP (www.itksnap.org) or VMTK (www.vmtk.org). The computational domain (the so-called mesh), used to solve the equilibrium equations governing the structural stent-vessel interaction, is created by an in-house developed procedure, coded in Matlab (The Mathworks Inc., Natick,MA, USA). The non-linear mechanical response of the arterial tissue is reproduced adopting an anisotropic hyperelastic strain-energy function, accounting for two families of fibers, oriented along a preferred direction with a certain degree of dispersion. The model parameters will be calibrated with respect to experimental tensile tests of the carotid tissue. The arterial model is then assembled in the simulation environment with a given stent model, picked from a predefined library of stent designs (the stent mesh generation is based on geometrical measurements performed on high-resolution micro-CT of stent samples). The CAS simulation is performed through structural finite element analysis (FEA); the commercial FEA solver Abaqus (Simulia, Dassault Systemes, FR), is adopted to run the simulations. The engineering outcomes of the simulations, (i.e. the nodal displacement field, stress tensor and strain at each integration points of the mesh), are elaborated to assess clinically relevant parameters of stenting performance (e.g. lumen gain, vessel straightening, stent cell size). The output will be used as an input of the Computational Fluid Dynamics analysis to evaluate the impact of the implanted design on the local haemodynamics (e.g., wall shear stress, oscillatory shear index, etc). Similarly, the structural analysis of CEA will be performed through the virtual pressurization of the post-operative arterial geometry.

Experimental design 3: Moving from Computational Fluid Dynamics and Fluid-Structure Interaction analysis, the investigators plan to introduce a specific model to describe the baroreflex function and this may be affected by the two different types of treatment (CEA and CAS). This requires the set up of a so-called "geometrical multiscale" model. With this, the investigators mean a numerical model coupling a local description of the hemodynamics (the one developed in Aim 2) with a more systemic representation. The latter consists of two components:

a) a 1D network mathematically described by a system of partial differential equations representing the propagation of the pressure wave along the arterial tree; each segment of the network is given by a hyperbolic system called "Euler equations" b) a compartment model for representing the peripheral microcirculation and for including the feedback mechanisms induced by the baroreflex function. Following, this will be represented by a system of ordinary differential equations where resistances properly depend on the baroreflex function.

In this aim the investigators plan two sub-aims:

  1. Set up of a computational multiscale model within the framework of the LifeV solver, a finite element general purpose C++ Object Oriented library, developed by A. Veneziani and his collaborators (in Milan Politecnico and Lausanne EPFL) www.lifev.org and openly downloadable. At this stage, the investigators will reproduce the general model of Blanco et al. In particular, the identification of the parameters for the two different levels of models (1D and Lumped Parameters) will be carried out following the procedure suggested. Validation of the solver will also take advantage of the benchmarks presented in this paper.
  2. Adoption of the solver previously developed for the test cases considered in Aim 2. This means that the 3D model developed in Aim 2 will be adopted for the 3D part of the geometrical multiscale model. This will allow to provide a quantitative analysis of the different impact of the two treatments and ultimately to assess in a virtual scenario how the changes of carotid compliance may impair the baroreflex function. All the CAS and CEA cases considered in Aim 2 will be equipped of this multiscale framework. The expected deliverables of this aim are therefore: a) a validated open source geometrical multiscale solver including the baroreflex function to be used systematically in patient-specific settings. b) extensive comparison of the performances of the different options.

Studientyp

Interventionell

Einschreibung (Tatsächlich)

70

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • Milan
      • San Donato Milanese, Milan, Italien, 20097
        • IRCCS Policlinico San Donato

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre bis 75 Jahre (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • Informed consent signed
  • Patients with >=70% symptomatic or >=80% asymptomatic internal carotid stenosis

Exclusion Criteria:

  • Incapability to give informed consent
  • Previous disabling stroke
  • Contralateral carotid occlusion or >70% stenosis
  • Systemic disease judged non compatible with the procedures or randomization
  • Suspected or manifested pregnancy
  • General contraindications to MRI or CT studies

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Aktiver Komparator: Carotid artery stenting (CAS)

Carotid revascularization performed using CAS

Carotid artery stenting (CAS) is an endovascular stent procedure used to treat narrowing of the carotid artery and decrease the risk of stroke

Aktiver Komparator: Carotid endarterectomy (CEA)

Carotid revascularization performed using CEA

Carotid endarterectomy (CEA) is a surgical procedure used to correct stenosis in the common carotid artery or internal carotid artery and reduce the risk of stroke

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
R-R interval (sec) and Systolic Arterial Pressure (SAP) (mmHg) in rest and tilt position for baroreceptor function
Zeitfenster: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

20 months

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Cognitive P300 latency (ms)
Zeitfenster: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

20 months
Mean and maximum flow velocity magnitude (cm/sec) in common carotid artery (CCA) and internal carotid artery (ICA) along the cardiac cycle
Zeitfenster: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

20 months
Systolic wall shear stress (dyn/cm2)
Zeitfenster: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

20 months
Time-averaged wall shear stress (TAWSS) (dyn/cm2)
Zeitfenster: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

20 months
Oscillatory index (OSI) (%)
Zeitfenster: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

20 months
Flow helicity (-)
Zeitfenster: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

20 months
CCA/ICA Flow split (%)
Zeitfenster: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

20 months
Common carotid artery (CCA) - internal carotid artery (ICA) mean and maximum pressure drop (mmHg)
Zeitfenster: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

20 months
Carotid wall von Mises stress (dyn/cm2) at the systolic peak
Zeitfenster: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

20 months
Carotid wall maximum principal stress (dyn/cm2) at the systolic peak and corresponding directions (-) Maximum, mean, and min principal strain (-) and corresponding directions (-)
Zeitfenster: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

20 months
Carotid augmentation index (%) of pressure wave
Zeitfenster: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

20 months
Effective reflecting distance (mm) of pressure wave
Zeitfenster: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

20 months

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Mitarbeiter

Publikationen und hilfreiche Links

Die Bereitstellung dieser Publikationen erfolgt freiwillig durch die für die Eingabe von Informationen über die Studie verantwortliche Person. Diese können sich auf alles beziehen, was mit dem Studium zu tun hat.

Allgemeine Veröffentlichungen

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

21. März 2018

Primärer Abschluss (Tatsächlich)

20. April 2022

Studienabschluss (Tatsächlich)

29. November 2023

Studienanmeldedaten

Zuerst eingereicht

5. Dezember 2017

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

3. April 2018

Zuerst gepostet (Tatsächlich)

11. April 2018

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

16. November 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

10. November 2026

Zuletzt verifiziert

1. November 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • 62/int/2017
  • PE-2013-02355484 (Andere Zuschuss-/Finanzierungsnummer: Ministero della Salute, Italia)

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .