Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

A Novel Two-Tooth Clip for ESD and EFTR of GIST

Efficacy and Safety of a Novel Two-Tooth Clip-Assisted ESD and EFTR of GIST: A Single-Center, Prospective, Open-Label, Randomized Controlled Study

This study is designed to evaluate the efficacy and safety of a novel two-tooth endoscopic clip, utilized in a "clip with line" traction configuration, during endoscopic resection procedures (ESD and EFTR) of GIST. The novel clip's dual-tooth design is intended to provide a more secure anchor on the lesion, enabling effective counter-traction when combined with a line. The primary aim is to determine if this method improves submucosal dissection efficiency compared to conventional ESD. A secondary aim is to evaluate the performance of the same clip system for full-thickness or mucosal defect closure.

Studienübersicht

Status

Rekrutierung

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

Endoscopic Submucosal Dissection (ESD) and Endoscopic Full-Thickness Resection (EFTR) are established, minimally invasive techniques for the en-bloc resection of gastrointestinal stromal tumor (GIST). However, a persistent challenge, especially in difficult locations or large lesions, is the lack of sufficient counter-traction, which leads to prolonged procedure times, increased risk of intraoperative bleeding, and potential for incomplete resection due to poor visualization of the submucosal layer. Furthermore, managing large post resection defects or perforations requires reliable and technically feasible endoscopic suturing.

This study introduces a novel two-tooth clip. The device's geometry is hypothesized to provide a stronger, more stable grasp on the targeted tissue compared to standard single-tooth or non-toothed clips. The study will investigate two sequential applications of this clip within a single procedure:

The Traction Phase: A "clip with line" technique will be employed. The novel two-tooth clip will be anchored to the proximal edge of the lesion. A dental line, pre-tied to the clip, will be used by the endoscopist to apply adjustable counter-traction. This is intended to lift the lesion, tauten the submucosal fibers, and clearly expose the dissection plane, thereby simulating the principle of surgical counter-traction.

The Closure Phase: Following lesion resection, the novel two-tooth clip will be utilized to perform a continuous, circumferential closure of the mucosal defect or perforation. The study will assess the technical success rate, time required for complete closure, and the clip's ability to securely approximate tissue layers.

Studientyp

Interventionell

Einschreibung (Geschätzt)

60

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studieren Sie die Kontaktsicherung

Studienorte

      • Beijing, China, 100071
        • Rekrutierung
        • The Fifth Medical Center of Chinese PLA General Hospital

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria:

  • Age ≥ 18 and ≤ 85 years.
  • Patients diagnosed with gastric gastrointestinal lesions clinically indicated for ESD or EFTR.
  • Lesion size between 2 cm and 5 cm in diameter.
  • Willing and able to provide written informed consent.

Exclusion Criteria:

  • Lesions with clear evidence of deep submucosal invasion or distant metastasis precluding curative endoscopic resection.
  • Severe coagulation dysfunction (international normalized ratio >2.0, platelet count <50,000/µL) or ongoing use of dual antiplatelet therapy/anticoagulants that cannot be appropriately bridged or discontinued per guidelines.
  • Severe organ failure (cardiac, renal, hepatic, or respiratory) rendering the patient unsuitable for prolonged sedation or general anesthesia.
  • Pregnancy or lactation.
  • Prior surgical or endoscopic intervention at the target lesion site that results in significant fibrosis.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: Novel Clip-Assisted Traction ESD/EFTR
Patients will undergo ESD or EFTR using the "clip with line" traction method with the novel two-tooth clip. After initial circumferential mucosal incision, the two-tooth clip (with pre-tied line) will be anchored to the lesion. The endoscopist will apply continuous or intermittent traction via the line to optimize the submucosal view. After lesion retrieval, defects requiring closure will be managed using the same novel two-tooth clips in a purse-string configuration.
"Clip with line" traction method with the novel two-tooth clip will be applied in patients undergoing ESD or EFTR. After lesion retrieval, defects requiring closure will be managed using the same novel two-tooth clips.
Aktiver Komparator: Conventional ESD/EFTR
Patients will undergo standard ESD or EFTR without the use of dedicated traction devices. The endoscopist may use transparent cap assistance and positional changes for exposure, which is current standard practice.
Standard ESD or EFTR without the use of dedicated traction devices will be performed, then using the standard clips for closure.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Submucosal Dissection Efficiency
Zeitfenster: 24 hours
The rate of submucosal dissection (measured in mm²/min), calculated from the start of submucosal entry to the completion of lesion removal.
24 hours

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Technical Success Rate of Purse-String Closure
Zeitfenster: 24 hours
Percentage of cases where complete, circumferential mucosal/full-thickness defect closure is achieved using the novel two-tooth clip without conversion to alternative closure devices.
24 hours
Defect Closure Time
Zeitfenster: 24 hours
Time taken to achieve complete purse-string closure of the post-resection defect.
24 hours
Incidence of Intraoperative Adverse Events
Zeitfenster: 3 days
  • Rates of immediate perforation (unintended) in both groups during the dissection phase
  • Rates of significant active bleeding requiring emergency hemostasis (aside from planned vessel coagulation) in both groups during the dissection phase
  • Rates of muscularis injury in both groups during the dissection phase
3 days
Post-procedural Outcomes
Zeitfenster: 3 months
  • Rates of delayed bleeding within 90 days
  • Rates of delayed perforation within 90 days
  • Rates of post-polypectomy electrocoagulation syndrome within 90 days
3 months

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Ermittler

  • Hauptermittler: Yan Liu, M.D.,Ph.D., Beijing 302 Hospital

Publikationen und hilfreiche Links

Die Bereitstellung dieser Publikationen erfolgt freiwillig durch die für die Eingabe von Informationen über die Studie verantwortliche Person. Diese können sich auf alles beziehen, was mit dem Studium zu tun hat.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

24. April 2026

Primärer Abschluss (Geschätzt)

24. April 2027

Studienabschluss (Geschätzt)

1. Juli 2027

Studienanmeldedaten

Zuerst eingereicht

6. Mai 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

6. Mai 2026

Zuerst gepostet (Tatsächlich)

12. Mai 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

22. Mai 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

20. Mai 2026

Zuletzt verifiziert

1. Mai 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Schlüsselwörter

Andere Studien-ID-Nummern

  • TTC-GIST

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .