Convective Radio-frequency Water Vapor Energy Verses Trans-urethral Enucleation of Prostate for Management of Benign Prostatic Hyperplasia
Prospective Study Comparing Convective Radio-frequency Water Vapor Energy With Trans-urethral Enucleation of Prostate for Management of Benign Prostatic Hyperplasia
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Studientyp
Studientyp
Einschreibung (Tatsächlich)
Einschreibung
Phase
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
-
Banī Suwayf, Ägypten
- Faculty of medicine Beni Suef University
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
- Erwachsene
- Älterer Erwachsener
Akzeptiert gesunde Freiwillige
Beschreibung
Inclusion Criteria:
- Male aged > 50 yrs.
- International Prostate Symptom Score (IPSS) >12
- Maximum flow rate ( Qmax ) < 15 ml/s for 125ml voided volume
- Post-void residual volume <350 ml
- Prostate volume 80-120 g
Exclusion Criteria:
- Active urinary tract infection at time of treatment.
- Prostate-specific antigen (PSA) more than 10 ng/l.
- history of prostate or bladder cancer.
- Anticoagulants within 3d of the index procedure
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Single
Anzahl der Arme
Waffen und Interventionen
Teilnehmergruppe / ArmTeilnehmergruppe / Arm |
Intervention / BehandlungIntervention / Behandlung |
|---|---|
|
Aktiver Komparator: Convective RF water vapor energy (Rezum)
|
Convective RF water vapor energy (Rezum)
|
|
Aktiver Komparator: Transurethral enucleation of prostate (TUEP)
|
transurethral enucleation of prostate (TUEP)
|
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
International Prostate Symptom Score (IPSS)
Zeitfenster: 1, 6, 12 months
|
The total score ranges from 0 to 35, where 0 indicates no symptoms and 35 indicates the most severe symptoms.
Higher scores represent worse urinary symptoms and poorer clinical status.
|
1, 6, 12 months
|
Sekundäre Ergebnismessungen
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
International Index of Erectile Function (IIEF-EF)
Zeitfenster: 1, 6, 12 months
|
The erectile function domain score ranges from 1 to 30, where lower scores indicate more severe erectile dysfunction and higher scores indicate better erectile function.
Higher scores represent better clinical outcomes.
|
1, 6, 12 months
|
|
four-item version of Male Sexual Health Questionnaire (MSHQ-EjD Short Form)
Zeitfenster: 1, 6, 12 months
|
The total score ranges from 1 to 15 for the ejaculatory function domain, with higher scores indicating better ejaculatory function.
In the bother item, scores range from 0 to 5, where higher scores indicate greater bother or distress related to ejaculatory dysfunction.
|
1, 6, 12 months
|
|
Qmax maximum urinary flow rate
Zeitfenster: 1, 6, 12 months
|
Maximum urinary flow rate (Qmax) will be assessed using uroflowmetry, a non-invasive urodynamic test that measures the maximum flow rate of urine during voiding.
Qmax is reported in milliliters per second (mL/s).
Higher values indicate better urinary flow and improved urinary function.
|
1, 6, 12 months
|
|
Post Void Residual volume (PVR)
Zeitfenster: 1, 6, 12 months
|
Post-Void Residual urine volume (PVR) will be assessed using bladder ultrasound immediately after voiding to determine the amount of urine remaining in the bladder.
PVR is reported in milliliters (mL).
Higher values indicate worse bladder emptying and poorer urinary function.
|
1, 6, 12 months
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Studienbeginn
Primärer Abschluss (Tatsächlich)
Primärer Abschluss
Studienabschluss (Tatsächlich)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- FMBSUREC/04062024/ Mohamed
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Produkt, das in den USA hergestellt und aus den USA exportiert wird
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .