Assessment of Hemodynamic Responses at Adequate Depth of Anesthesia Using Bispectral Index During Rapid Sequence Intubation in the Emergency Department
Rapid sequence intubation (RSI) is the standard approach for emergency airway management in critically ill patients requiring endotracheal intubation. Laryngoscopy and tracheal intubation may provoke significant hemodynamic responses, including increases in heart rate and blood pressure, which may adversely affect patients with severe neurological or cardiovascular disease.
Although hemodynamic responses during tracheal intubation have been extensively investigated in the anesthesiology literature, evidence from emergency department settings remains limited. Furthermore, previous studies have rarely confirmed whether an adequate depth of anesthesia had been achieved before laryngoscopy, making interpretation of hemodynamic responses difficult.
The aim of this prospective observational study is to evaluate hemodynamic responses during rapid sequence intubation in adult emergency department patients after confirming adequate depth of anesthesia using bispectral index (BIS) monitoring. Heart rate and blood pressure will be recorded before induction, during intubation, and after successful endotracheal intubation, allowing objective assessment of the hemodynamic response under confirmed adequate anesthetic depth.
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Detaillierte Beschreibung
Rapid sequence intubation (RSI) is the standard approach for emergency airway management in critically ill patients requiring endotracheal intubation. Laryngoscopy and tracheal intubation may provoke significant hemodynamic responses, including increases in heart rate and blood pressure, which may adversely affect patients with severe neurological or cardiovascular disease.
Although hemodynamic responses during tracheal intubation have been extensively investigated in the anesthesiology literature, evidence from emergency department settings remains limited. Furthermore, previous studies have rarely confirmed whether an adequate depth of anesthesia had been achieved before laryngoscopy, making interpretation of hemodynamic responses difficult.
The aim of this prospective observational study is to evaluate hemodynamic responses during rapid sequence intubation in adult emergency department patients after confirming adequate depth of anesthesia using bispectral index (BIS) monitoring. Heart rate and blood pressure will be recorded before induction, during intubation, and after successful endotracheal intubation, allowing objective assessment of the hemodynamic response under confirmed adequate anesthetic depth.
Studientyp
Studientyp
Einschreibung (Geschätzt)
Einschreibung
Kontakte und Standorte
Studienkontakt
Studienkontakt
- Name: Erkan Göksu, MD
- Telefonnummer: +905054691764
- E-Mail: erkangoksu@akdeniz.edu.tr
Studienorte
-
-
-
Antalya, Türkei (türkiye), 07059
- Rekrutierung
- Akdeniz University Hospital
-
Kontakt:
- Erkan Göksu, MD
- Telefonnummer: 05054691764
- E-Mail: erkangoksu@akdeniz.edu.tr
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
- Erwachsene
- Älterer Erwachsener
Akzeptiert gesunde Freiwillige
Probenahmeverfahren
Studienpopulation
Beschreibung
Inclusion Criteria:
Adults aged 18 years or older. Patients undergoing rapid sequence intubation (RSI) in the emergency department.
Patients in whom bispectral index (BIS) monitoring can be applied before laryngoscopy.
Patients achieving an adequate depth of anesthesia (BIS 45-55) before laryngoscopy.
Written informed consent obtained from the patient or a legally authorized representative, when applicable according to local ethics requirements.
Exclusion Criteria:
Age <18 years. Cardiac arrest before or during induction. Patients requiring immediate ("crash") intubation without sufficient time for BIS monitoring.
Inability to obtain reliable BIS monitoring (e.g., technical failure or inability to place the sensor).
Pregnancy. Facial or scalp conditions preventing BIS sensor placement. Prisoners or other vulnerable populations if excluded by the ethics protocol.
-
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
Anzahl der Gruppen / Kohorten
Kohorten und Interventionen
Gruppe / KohorteGruppe / Kohorte |
Intervention / BehandlungIntervention / Behandlung |
|---|---|
|
Emergency Department Patients Undergoing Rapid Sequence Intubation
Adult patients undergoing rapid sequence intubation in the emergency department.
Bispectral index (BIS) monitoring is used to confirm adequate depth of anesthesia before laryngoscopy.
Hemodynamic parameters are recorded before, during, and after endotracheal intubation.
|
Bispectral index monitoring is used to assess the depth of anesthesia before laryngoscopy.
Endotracheal intubation is performed after an adequate BIS value has been achieved.
|
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Change in Diastolic Blood Pressure Following Rapid Sequence Intubation
Zeitfenster: Baseline, immediately after intubation, and 5, 10, and 15 minutes after intubation
|
Diastolic Blood pressure (MAP) measured before induction, immediately after endotracheal intubation, and at 5, 10, and 15 minutes after intubation in patients with BIS-confirmed adequate depth of anesthesia.
|
Baseline, immediately after intubation, and 5, 10, and 15 minutes after intubation
|
|
Change in Systolic Blood Pressure Following Rapid Sequence Intubation
Zeitfenster: Baseline, immediately after intubation, and 5, 10, and 15 minutes after intubation
|
Systolic Blood pressure measured before induction, immediately after endotracheal intubation, and at 5, 10, and 15 minutes after intubation in patients with BIS-confirmed adequate depth of anesthesia.
|
Baseline, immediately after intubation, and 5, 10, and 15 minutes after intubation
|
|
Change in Heart Rate Following Rapid Sequence Intubation
Zeitfenster: Baseline, immediately after intubation, and 5, 10, and 15 minutes after intubation
|
Heart Rate measured before induction, immediately after endotracheal intubation, and at 5, 10, and 15 minutes after intubation in patients with BIS-confirmed adequate depth of anesthesia.
|
Baseline, immediately after intubation, and 5, 10, and 15 minutes after intubation
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Publikationen und hilfreiche Links
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Studienbeginn
Primärer Abschluss (Geschätzt)
Primärer Abschluss
Studienabschluss (Geschätzt)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- AkdenizUH1
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .