Continuous Monitoring of Body Temperature in Mothers and Their Preterm Neonates (MonT NeoP)
Continuous Monitoring of Body Temperature in Mothers and Their Preterm Neonates During the Immediate Postnatal Transition - A Prospective Observational Pilot Study
Preterm babies are at increased risk of becoming too cold or too warm immediately after birth because they have an immature ability to regulate their body temperature. Maintaining a normal body temperature during the first minutes after birth is important because both low and high body temperatures are associated with an increased risk of complications. Current temperature monitoring is performed intermittently using conventional thermometers and does not provide continuous information about changes in body temperature.
This prospective observational pilot study aims to evaluate the feasibility of using the SteadyTemp® adhesive thermometer, a wireless, non-invasive temperature sensor, for continuous body temperature monitoring in preterm neonates (32+0 to 36+6 weeks of gestation) during the first 15 minutes after birth. The study will also compare temperatures recorded by the adhesive thermometer with a routine rectal temperature measurement and assess skin tolerability after removal of the adhesive patch. In addition, maternal body temperature will be continuously monitored during delivery to explore the relationship between maternal intrapartum temperature and neonatal temperature during the immediate postnatal transition.
The study hypothesizes that continuous temperature monitoring with the SteadyTemp® adhesive thermometer is feasible in preterm neonates, that the recorded temperatures agree with standard rectal temperature measurements, that the device is well tolerated without clinically relevant skin irritation, and that maternal intrapartum temperature correlates with neonatal body temperature during the immediate postnatal transition. The results of this pilot study will provide preliminary evidence to support future studies evaluating continuous, non-invasive temperature monitoring as a tool to improve thermal management of preterm neonates immediately after birth.
Studienübersicht
Status
Status
Bedingungen
Bedingungen
Intervention / Behandlung
Intervention / Behandlung
Detaillierte Beschreibung
This is a prospective, multicenter, observational pilot study conducted at the Medical University of Graz, Austria, and the University Hospital Essen, Germany, to evaluate the feasibility, performance, and safety of continuous non-invasive body temperature monitoring using the SteadyTemp® wireless adhesive thermometer in moderately preterm neonates during the immediate postnatal transition. In addition, maternal intrapartum body temperature will be continuously monitored to explore the relationship between maternal and neonatal thermal regulation during the perinatal period.
Maintaining normothermia immediately after birth is a key component of neonatal care, particularly for preterm infants, who are at increased risk of thermal instability because of immature thermoregulation, limited brown adipose tissue, and a high surface area-to-volume ratio. Both hypothermia and hyperthermia are associated with increased neonatal morbidity and mortality. Conventional temperature assessment methods provide only intermittent measurements and do not permit continuous monitoring during the critical transition after birth. The SteadyTemp® adhesive thermometer is a wireless, skin-adherent device that continuously records body temperature and transfers the data via near-field communication (NFC). Although the device has previously been evaluated in adults and term neonates, its feasibility and performance in preterm neonates have not yet been investigated.
Following informed consent before delivery, the SteadyTemp® adhesive thermometer will be applied to the mother at least 10 minutes before birth to enable continuous intrapartum temperature monitoring. Immediately after birth, a second SteadyTemp® adhesive thermometer will be applied to the right axillary region of the preterm neonate and will continuously record body temperature during the first 15 minutes of postnatal transition. After completion of monitoring, the adhesive patch will be removed and neonatal skin integrity will be assessed using the Neonatal Skin Condition Scale (NSCS). As part of routine clinical care, a single rectal body temperature measurement will be obtained using the locally established reference thermometer and used for comparison with the temperature recorded by the investigational device. No study-specific therapeutic interventions are performed beyond application of the adhesive thermometers.
The study plans to enroll 80 participants, comprising 40 mother-preterm neonate pairs. The sample size was determined to provide adequate precision for estimating the feasibility of continuous temperature monitoring based on results from a previous pilot study in term neonates. The study is intended to generate preliminary evidence regarding device feasibility, agreement with routine clinical temperature measurements, skin tolerability, and the relationship between maternal and neonatal temperatures to support the design of future confirmatory studies.
Statistical analyses will primarily be descriptive. Continuous variables will be summarized using means and standard deviations or medians and interquartile ranges, as appropriate, while categorical variables will be presented as counts and percentages. Feasibility will be reported as the proportion of successful uninterrupted temperature recordings with corresponding 95% confidence intervals. Agreement between SteadyTemp® and rectal temperature measurements will be evaluated using Bland-Altman analysis and correlation analysis. Skin tolerability will be summarized descriptively, and changes in skin condition will be assessed when baseline assessments are available. Associations between maternal intrapartum temperature and neonatal temperature during the immediate postnatal transition will be explored using correlation analyses and longitudinal linear mixed models adjusted for relevant clinical variables. Statistical analyses will be performed using R software, and a two-sided p-value <0.05 will be considered statistically significant.
Study data will be recorded in paper-based case report forms using pseudonymized participant identifiers. Personal data will be handled in accordance with applicable data protection regulations and archived for the legally required retention period. Data quality will be ensured through double verification of data entry and independent monitoring according to a predefined monitoring plan. Source data verification will be performed by comparing case report forms with original medical records in accordance with ISO(International Organization for Standardization) 14155, ICH(International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use)-GCP(Good Clinical Practice), and applicable regulatory requirements. All study personnel will receive protocol-specific training, and written standard operating procedures will govern study conduct, data collection, monitoring, and use of the investigational device.
The Sponsor applies a risk-based quality management approach throughout the clinical investigation. Potential study-specific risks, protocol deviations, adverse events, and device deficiencies will be continuously monitored, documented, and managed in accordance with the clinical investigation plan and Regulation (EU) 2017/745. The study will be conducted in compliance with ISO 14155, ICH-GCP, the Declaration of Helsinki, and applicable national regulations governing clinical investigations of medical devices.
Studientyp
Studientyp
Einschreibung (Geschätzt)
Einschreibung
Kontakte und Standorte
Studienkontakt
Studienkontakt
- Name: Nariae Baik-Schneditz, MD. PhD.
- Telefonnummer: +43 316 385 82677
- E-Mail: nariae.baik@medunigraz.at
Studieren Sie die Kontaktsicherung
- Name: Lukas Mileder, MD.PhD.
- E-Mail: lukas.mileder@medunigraz.at
Studienorte
-
-
Styria
-
Graz, Styria, Österreich, 8034
- Medical University Graz
-
Kontakt:
- Gerhard Pichler, Prof.
- Telefonnummer: +43 316 385 80520
- E-Mail: gerhard.pichler@medunigraz.at
-
-
Teilnahmekriterien
Zulassungskriterien
Zulassungskriterien
Studienberechtigtes Alter
- Kind
- Erwachsene
- Älterer Erwachsener
Akzeptiert gesunde Freiwillige
Probenahmeverfahren
Studienpopulation
Beschreibung
Inclusion Criteria:
- Preterm neonates born between 32+0 and 36+6 weeks of gestation.
- Written informed consent obtained from the mother (or legally authorized representative, where applicable according to national legislation) before delivery and before any study-specific procedures are performed.
Exclusion Criteria:
- Gestational age <32+0 weeks or ≥37+0 weeks.
- No decision to conduct full life support.
- Written informed consent not obtained before delivery.
- Congenital malformation.
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
Anzahl der Gruppen / Kohorten
Kohorten und Interventionen
Gruppe / KohorteGruppe / Kohorte |
Intervention / BehandlungIntervention / Behandlung |
|---|---|
|
Mother-Preterm Neonate Pairs
The study cohort consists of mother-preterm neonate pairs.
Preterm neonates will undergo continuous body temperature monitoring using the SteadyTemp® adhesive thermometer during the first 15 minutes after birth, while mothers will undergo continuous intrapartum temperature monitoring during delivery.
Neonatal temperatures will be compared with a routine single rectal temperature measurement, and maternal and neonatal temperature profiles will be explored to assess their relationship during the immediate postnatal transition.
|
SteadyTemp® (SteadySense GmbH, Graz, Austria) is a wireless, non-invasive adhesive thermometer designed for continuous body temperature monitoring.
In this study, one adhesive thermometer will be applied to the mother's skin at least 10 minutes before delivery for continuous intrapartum temperature monitoring, and a second thermometer will be applied to the preterm neonate's right axillary region immediately after birth for continuous temperature monitoring during the first 15 minutes of postnatal transition.
Temperature data are recorded continuously and transferred via near-field communication (NFC).
The device is used in addition to standard clinical care and does not replace routine rectal temperature measurement, which serves as the clinical reference standard.
|
Was misst die Studie?
Primäre Ergebnismessungen
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Feasibility of continuous body temperature monitoring using the SteadyTemp® adhesive thermometer in preterm neonates
Zeitfenster: 15 minutes
|
Feasibility will be assessed as the proportion of preterm neonates with successful placement of the SteadyTemp® adhesive thermometer and uninterrupted continuous body temperature recording during the first 15 minutes after birth.
|
15 minutes
|
Sekundäre Ergebnismessungen
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Agreement between SteadyTemp® and rectal body temperature measurements
Zeitfenster: 15 minutes after birth (at the time of routine rectal temperature measurement).
|
Agreement between the temperature recorded by the SteadyTemp® adhesive thermometer and the single routine rectal temperature measurement will be assessed using Bland-Altman analysis and correlation analysis.
|
15 minutes after birth (at the time of routine rectal temperature measurement).
|
|
Neonatal skin tolerability after application of the SteadyTemp® adhesive thermometer
Zeitfenster: Immediately after removal of the adhesive thermometer (15 minutes after birth).
|
Neonatal skin tolerability after application of the SteadyTemp® adhesive thermometer
|
Immediately after removal of the adhesive thermometer (15 minutes after birth).
|
|
Association between maternal intrapartum temperature and neonatal body temperature during immediate postnatal transition
Zeitfenster: From approximately 10 minutes before birth until 15 minutes after birth.
|
Correlation between continuously measured maternal intrapartum temperature and neonatal body temperature during the first 15 minutes after birth.
|
From approximately 10 minutes before birth until 15 minutes after birth.
|
Mitarbeiter und Ermittler
Sponsor
Sponsor
Mitarbeiter
Mitarbeiter
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Geschätzt)
Studienbeginn
Primärer Abschluss (Geschätzt)
Primärer Abschluss
Studienabschluss (Geschätzt)
Studienabschluss
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Zuerst gepostet
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes Update gepostet
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Andere Studien-ID-Nummern
Andere Studien-ID-Nummern
- 1222/2025
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .