Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Augmented Reality Aided Remote Access and Technical Support for Complex Ablation Procedures (HOLO-Remote)

16. August 2026 aktualisiert von: Roland Richard Tilz, MD, University of Luebeck

Augmented Reality Aided Remote Access and tecHnical suppOrt for compLex ablatiOn Procedures

Prospective, randomized, controlled, single-center pilot study evaluating the feasibility and safety of augmented reality-based remote technical support using the Microsoft HoloLens and EnSite™ Connected Care compared with conventional on-site support during 3D electroanatomical mapping-guided electrophysiological procedures. The study also assesses the feasibility of an AI-based algorithm integrated into the Medinbox Link system for automated procedural report generation and detection of protocol deviations from standard clinical practice.

Studienübersicht

Status

Noch keine Rekrutierung

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

Prospective, randomized, controlled, monocentric, pilot study to evaluate the feasibility and safety of remote access and technical support using an augmented reality system (Microsoft HoloLens headset) in association with the EnSite™ Connected Care solution (EnSite™ Connect Remote Support, Abbott and Medinbox system, Medinbox) as compared to the on-site support for three-dimensional (3D) electroanatomical mapping-based electrophysiological (EP) procedures. Moreover, the study will evaluate the feasibility of an artificial intelligence (AI)-based algorithm integrated within the Medinbox Link system (Medinbox) to analyse video and audio recordings obtained during the procedure, with the aim of automatically generating procedural reports and identifying protocol deviations from the standard of care.

Studientyp

Interventionell

Einschreibung (Geschätzt)

60

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

  • Name: Roland R Tilz, M.D.
  • Telefonnummer: +49 451 500 44580
  • E-Mail: tilz6@hotmail.de

Studieren Sie die Kontaktsicherung

Studienorte

      • Lübeck, Deutschland, 23538
        • University Hospital Schleswig-Holstein
        • Kontakt:

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria:

  • Patients age ≥ 18 years
  • Indication for 3D electroanatomical mapping-based catheter ablation for the treatment of AF
  • Signed written informed consent

Exclusion Criteria:

  • Patient is unable or unwilling to provide informed consent
  • Patient is included in another randomised clinical trial
  • Inability to comply with the study procedures

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: HoloLens Group
Patients undergoing 3D electroanatomical mapping-based AF ablation procedures using the EnSite™ X EP System operated remotely by means of the EnSite™ Connected Care solution (EnSite™ Connect Remote Support, Abbott and Medinbox system, Medinbox) and the Microsoft HoloLens (Microsoft).
Patients undergoing 3D electroanatomical mapping-based AF ablation procedures using the EnSite™ X EP System operated remotely by means of the EnSite™ Connected Care solution (EnSite™ Connect Remote Support, Abbott and Medinbox system, Medinbox) and the Microsoft HoloLens (Microsoft). The HoloLens headset will be implemented to facilitate the communication between the principal operator and the FTE (working in Home Office). The FTE will not be present on site.
Aktiver Komparator: On-site Group
Patients undergoing 3D electroanatomical mapping-based AF ablation procedures using the EnSite™ X EP System operated by the FTE on site, in the Minimal Invasive Centre (MIC) of the hospital. The HoloLens headset and the EnSite™ Connected Care solution will not be used. The communication between the operator (in the operating room) and the FTE (in the control room) will be established by means of radio-based headphones.
Patients undergoing 3D electroanatomical mapping-based AF ablation procedures using the EnSite™ X EP System operated by the FTE on site, in the Minimal Invasive Centre (MIC) of the hospital. The HoloLens headset and the EnSite™ Connected Care solution will not be used. The communication between the operator (in the operating room) and the FTE (in the control room) will be established by means of radio-based headphones.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Feasibility: Number of participants in whom remotely supported 3D electroanatomical mapping-based atrial fibrillation ablation is successfully completed
Zeitfenster: At the end of the catheter ablation procedure.
Feasibility will be assessed as the number and percentage of participants in whom the planned 3D electroanatomical mapping-guided atrial fibrillation ablation procedure is successfully completed using remote technical support provided through an augmented reality system (Microsoft HoloLens headset) in conjunction with the EnSite™ Connected Care solution (EnSite™ Connect Remote Support, Abbott) and the Medinbox system. Successful completion is defined as completion of the planned mapping and ablation procedure without conversion to on-site technical support because of technical failure of the remote support system.
At the end of the catheter ablation procedure.

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Number of participants with periprocedural adverse events
Zeitfenster: Periprocedural (from initiation of the catheter ablation procedure until hospital discharge)
Periprocedural adverse events occurring during the catheter ablation procedure and throughout the index hospitalization will be recorded.
Periprocedural (from initiation of the catheter ablation procedure until hospital discharge)
Procedural time
Zeitfenster: At the end of catheter ablation procedure
Procedural time
At the end of catheter ablation procedure
Fluoroscopy time
Zeitfenster: End of the catheter ablation procedure
Total fluoroscopy time (minutes) recorded during the catheter ablation procedure.
End of the catheter ablation procedure
Number of participants with successful completion of the intended catheter ablation procedure (the minimum procedural endpoint is successful pulmonary vein isolation)
Zeitfenster: End of the catheter ablation procedure
Procedural success will be assessed as successful completion of the intended catheter ablation procedure. A minimum procedural endpoint is successful pulmonary vein isolation (PVI), confirmed by entrance block in all pulmonary veins. Additional ablations may be performed at the operator's discretion based on the patient's clinical characteristics and the planned treatment strategy. When additional ablations are planned or performed, procedural success also requires successful completion of these additional lesion sets according to the predefined procedural objectives.
End of the catheter ablation procedure
Number of participants requiring conversion from remote technical support to on-site technical support
Zeitfenster: End of the catheter ablation procedure
The number of participants in whom the planned remote technical support could not be maintained and conversion to conventional on-site technical support was required because of technical or procedural reasons (only for interventional group)
End of the catheter ablation procedure
Technical issues
Zeitfenster: At the end of catheter ablation procedure
Technical issues with the remote support system and technical issues with the augmented reality system
At the end of catheter ablation procedure
Estimated carbon dioxide emissions associated with technical support
Zeitfenster: End of the catheter ablation procedure
Estimated carbon dioxide (CO₂) emissions (kg CO₂ equivalent) associated with travel of field technical engineers to and from the participating study site. Emissions will be calculated from the recorded driving distance using a predefined standardized emission factor. In the remote support group, CO₂ emissions will be calculated based on the estimated distance the field technical engineers would drive if they would have to be on site.
End of the catheter ablation procedure
Operator satisfaction with the procedural workflow assessed using 10-point numeric rating scales
Zeitfenster: End of the catheter ablation procedure
Operator satisfaction with the procedural workflow will be assessed immediately after completion of the catheter ablation procedure using a 10-point numeric rating scale (NRS), where 0 indicates "not satisfied at all" and 10 indicates "completely satisfied."
End of the catheter ablation procedure
Successful development of an artificial intelligence algorithm for analysis of recorded catheter ablation procedures to assess predefined procedural quality criteria
Zeitfenster: By completion of the AI algorithm development phase, up to 3 months after completion of data collection
Feasibility will be assessed by whether the recorded procedural data from the intervention group are sufficient to develop an artificial intelligence (AI)-based algorithm capable of analyzing predefined procedural quality criteria . The outcome will be reported as successful or unsuccessful algorithm development according to predefined technical performance criteria.
By completion of the AI algorithm development phase, up to 3 months after completion of data collection
Radiation dose
Zeitfenster: End of the catheter ablation procedure
Total radiation exposure recorded during the catheter ablation procedure, reported as dose area product (DAP, Gy·cm²).
End of the catheter ablation procedure
Number of participants requiring conversion from HoloLens-assisted remote support to conventional remote support
Zeitfenster: End of the catheter ablation procedure
The number of participants in the intervention group in whom HoloLens-assisted remote technical support could not be maintained and support was continued using conventional remote communication without the Microsoft HoloLens headset because of technical or procedural reasons.
End of the catheter ablation procedure
Driving time of field technical engineers
Zeitfenster: End of the catheter ablation procedure
Driving time (minutes) required for field technical engineers to travel to and from the participating study site. For participants assigned to the remote support group, driving time will be estimated based on the hypothetical travel time that field technical engineers would have required had conventional on-site technical support been provided.
End of the catheter ablation procedure
Driving distance of field technical engineers
Zeitfenster: End of the catheter ablation procedure
Driving distance (kilometers) traveled by field technical engineers to and from the participating study site. For participants assigned to the remote support group, driving distance will be estimated based on the hypothetical distance that field technical engineers would have traveled had conventional on-site technical support been provided.
End of the catheter ablation procedure
Field technical engineer satisfaction with the procedural workflow assessed using 10-point numeric rating scales
Zeitfenster: End of the catheter ablation procedure
Field technical engineer satisfaction with the procedural workflow will be assessed immediately after completion of the catheter ablation procedure using a 10-point numeric rating scale (NRS), where 0 indicates "not satisfied at all" and 10 indicates "completely satisfied."
End of the catheter ablation procedure
Successful development of an artificial intelligence algorithm for analysis of recorded catheter ablation procedures to generate automated procedural reports
Zeitfenster: By completion of the AI algorithm development phase, up to 3 moths after completion of data collection
Feasibility will be assessed by whether the recorded procedural data from the intervention group are sufficient to develop an artificial intelligence (AI)-based algorithm capable of generating automated procedural reports. The outcome will be reported as successful or unsuccessful algorithm development according to predefined technical performance criteria.
By completion of the AI algorithm development phase, up to 3 moths after completion of data collection

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Ermittler

  • Hauptermittler: Roland R Tilz, M.D., University of Lübeck, Department of Rhythmology
  • Hauptermittler: Sorin S Popescu, M.D., University of Lübeck, Department of Rhythmology

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

1. August 2026

Primärer Abschluss (Geschätzt)

1. Februar 2028

Studienabschluss (Geschätzt)

1. Februar 2028

Studienanmeldedaten

Zuerst eingereicht

5. August 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

16. August 2026

Zuerst gepostet (Tatsächlich)

20. August 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

20. August 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

16. August 2026

Zuletzt verifiziert

1. August 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • 2025-221

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Beschreibung des IPD-Plans

Data supporting the study are curated at the Clinical Trial Unit of the Department of Rhythmology, University Hospital Schleswig-Holstein, Lübeck, Germany. These data are not shared openly but are available on reasonable request from the corresponding authors.

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .