Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Reticulocyte Hemoglobin Equivalent (RET-He) in Early Detection of Iron Deficiency Among Blood Donors and Its Potential Impact on Donor Eligibility and Transfusion Safety

1. Oktober 2026 aktualisiert von: Tasneem Ashraf AbdelHafiz, Assiut University

Role of Reticulocyte Hemoglobin Equivalent (RET-He) in Early Detection of Iron Deficiency Among Blood Donors and Its Potential Impact on Donor Eligibility and Transfusion Safety

Blood donation is essential for healthcare, but repeated whole-blood donation can deplete the body's iron stores. Standard pre-donation screening relies on hemoglobin levels to ensure donor safety; however, a drop in hemoglobin is a late sign of iron deficiency. Consequently, donors with subclinical or latent iron depletion often pass standard pre-donation screening unnoticed.

The primary purpose of this study is to evaluate the clinical utility of Reticulocyte Hemoglobin Equivalent (RET-He) as an early laboratory marker for detecting iron deficiency among accepted blood donors. Because reticulocytes are newly formed red blood cells, RET-He reflects iron availability for hemoglobin production over the preceding few days, potentially detecting iron limitation much earlier than mature red blood cell indices or standard hemoglobin testing.

In this prospective observational study, approximately 300 eligible voluntary blood donors aged 18 to 60 years will be enrolled at the Main Blood Bank of Assiut University Hospitals. At the time of routine donation, blood samples will be analyzed for complete blood count (CBC) with RET-He, serum ferritin, iron profile (serum iron, total iron-binding capacity, and transferrin saturation), and C-reactive protein (CRP) to control for inflammation. Participants will also be reassessed at their subsequent regular donation visit (after 90 days for males and 120 days for females) to evaluate changes in iron indices over time and explore whether adding RET-He improves donor eligibility assessment and long-term donor health.

Studienübersicht

Status

Noch keine Rekrutierung

Bedingungen

Studientyp

Beobachtungs

Einschreibung (Geschätzt)

300

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre bis 60 Jahre (Erwachsene)

Akzeptiert gesunde Freiwillige

N/A

Studienberechtigte Geschlechter

Alle

Probenahmeverfahren

Nicht-Wahrscheinlichkeitsprobe

Studienpopulation

The study population consists of voluntary adult blood donors attending the Main Blood Bank at the Central Blood Transfusion Services (CBTS), Department of Clinical Pathology, Assiut University Hospitals, Assiut, Egypt. Eligible participants comprise healthy male and female donors aged 18 to 60 years who fulfill routine national and institutional donor-selection standards, including pre-donation hemoglobin eligibility thresholds (Hb ≥ 14 g/dL for males and ≥ 12 g/dL for females).

Beschreibung

Inclusion Criteria:

  • Voluntary blood donors eligible for donation according to standard national and institutional donor-selection criteria.
  • Adults aged 18 to 60 years.
  • Meeting accepted pre-donation hemoglobin thresholds for blood donation (hemoglobin ≥ 14.0 g/dL for males and ≥ 12.0 g/dL for females).
  • Both male and female donors eligible under local blood donation policies.
  • Provision of written informed consent prior to study participation.

Exclusion Criteria:

  • Known hematological disorders or chronic anemia unrelated to iron deficiency.
  • Known chronic kidney disease, active malignancy, or chronic inflammatory/autoimmune diseases.
  • History of recent blood transfusion.
  • Recent therapeutic iron treatment or regular iron supplementation within the preceding 3 months.
  • History of recent major bleeding or major surgery.
  • Inadequate or hemolyzed blood sample, or inability to obtain valid RET-He, complete blood count (CBC), or iron panel measurements.
  • Donors who withdraw consent.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Beobachtungsmodelle: COHORT
  • Zeitperspektiven: PROSPECTIVE

Kohorten und Interventionen

Gruppe / Kohorte
Eligible Voluntary Blood Donors

Voluntary blood donors aged 18 to 60 years who meet routine institutional pre-donation eligibility criteria, including acceptable hemoglobin levels (Hb ≥ 14 g/dL for males and ≥ 12 g/dL for females). Enrolled participants undergo blood sampling for complete blood count (CBC) and reticulocyte hemoglobin equivalent (RET-He) using the Atellica HEMA 580 automated analyzer. Serum ferritin is assessed on the ADVIA Centaur XPT platform, alongside serum iron, total iron-binding capacity (TIBC), calculated transferrin saturation (TSAT), and C-reactive protein (CRP). Participants are evaluated for latent/subclinical iron deficiency and followed up at their subsequent donation visit (90 days for males and 120 days for females).

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Area Under the Receiver Operating Characteristic Curve of RET-He for Detecting Iron Deficiency
Zeitfenster: Baseline

The Area Under the Receiver Operating Characteristic Curve (AUC-ROC) will assess the diagnostic accuracy of Reticulocyte Hemoglobin Equivalent (RET-He, measured in pg via the Atellica HEMA 580 analyzer) in identifying iron deficiency among accepted blood donors. Iron deficiency is defined using reference biochemical markers, including serum ferritin (measured via the ADVIA Centaur XPT analyzer) and transferrin saturation (TSAT), in the context of C-reactive protein (CRP) levels to account for inflammation. The AUC-ROC score ranges from 0.5 (discrimination no better than chance) to 1.0 (perfect diagnostic discrimination).

Baseline

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

1. November 2026

Primärer Abschluss (Geschätzt)

1. November 2027

Studienabschluss (Geschätzt)

1. Dezember 2027

Studienanmeldedaten

Zuerst eingereicht

1. Oktober 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

1. Oktober 2026

Zuerst gepostet (Tatsächlich)

6. Oktober 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

6. Oktober 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

1. Oktober 2026

Zuletzt verifiziert

1. Oktober 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • RET-He in Donor Iron Status

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .