Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

AI-Driven Hip Exoskeleton Control for Diverse Users and Walking Tasks

10. November 2026 aktualisiert von: Inseung Kang, Carnegie Mellon University

AI-Driven Hip Exoskeleton Control Framework That Rapidly Generalizes to a Broad Range of Users and Real-World Locomotor Tasks

The goal of this clinical trial is to evaluate the feasibility of a prototype artificial intelligence (AI)-based controller for a lightweight hip exoskeleton across a broad range of users, including healthy younger adults (18-39 years) and older adults (65 years and older). The main questions it aims to answer are:

  • Can the AI-based controller accurately estimate gait phase in real time across younger and older adults?
  • How does hip exoskeleton assistance change walking energy cost, mechanics, and muscle activity?

Researchers will compare walking with powered hip exoskeleton assistance to walking without the exoskeleton and walking while wearing the exoskeleton with no assistance (zero torque).

Participants will:

  • Complete a short screening and frailty assessment
  • Walk on a treadmill under different conditions with and without the hip exoskeleton during 2 to 5 lab visits
  • Wear motion capture markers, muscle activity (EMG) sensors, and a mask that measures breathing to estimate energy use

Studienübersicht

Status

Rekrutierung

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

This study is funded by the National Institute of Biomedical Imaging and Bioengineering (R21EB037268) and conducted at the University of Texas at Austin in collaboration with Carnegie Mellon University. The CMU Hip Exoskeleton is a research prototype with powered hip joints for flexion and extension (peak torque 18 Nm, total weight 3.5 kg). Its controller uses joint angle and user-state estimates to command assistive torque, limited to less than 0.2 Nm/kg (at most about 30% of typical biological hip moments during walking), so it supplements rather than overrides the user's own muscle effort.

During each visit, participants walk on a force-instrumented treadmill at 1.25 m/s with safety harness and handrails. Researchers record whole-body motion capture, ground reaction forces, inertial measurement unit data, lower-limb electromyography, and metabolic energy expenditure via open-circuit indirect calorimetry. Walking conditions include no exoskeleton, exoskeleton worn with zero torque, and powered exoskeleton assistance. Outcomes will be compared across conditions and between younger and older adults using repeated-measures statistical analysis.

Studientyp

Interventionell

Einschreibung (Geschätzt)

16

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studienorte

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre und älter (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Ja

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • Age 18 to 39 years (younger adult group) or 65 years and older (older adult group)
  • Willing and able to provide informed consent
  • Able to walk independently without assistance
  • No known cardiovascular, metabolic, or renal disease, and no signs or symptoms suggestive of such disease
  • Cleared for light- to moderate-intensity exercise without the need for medical clearance under American College of Sports Medicine (ACSM) preparticipation screening guidelines

Exclusion Criteria:

  • Age 40 to 64 years
  • Leg surgery within the past 5 years
  • Orthopedic disability that could impair movement or limit participation in the exercise protocol
  • Neurologic disorder that may affect neuromuscular function or gait (e.g., stroke, Parkinson's disease, peripheral neuropathy, traumatic brain injury)
  • Known metabolic or cardiovascular disease (hypertension alone is not exclusionary), or requiring medical clearance under ACSM guidelines without having obtained it
  • Metal implants in the lower extremities, cardiac pacemaker, or other implanted electronic device
  • Pregnancy
  • History of seizure disorder or fainting (syncope)

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Machbarkeit des Geräts
  • Zuteilung: N / A
  • Interventionsmodell: Einzelgruppenzuweisung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: Hip Exoskeleton Walking

Healthy younger adults (18-39 years) and older adults (65+ years) walk on an instrumented treadmill under multiple conditions across 2-5 lab visits: no exoskeleton, wearing the CMU Hip Exoskeleton with zero torque, and with powered assistance from the AI-driven hip exoskeleton controller (assistance limited to <0.2 Nm/kg). The primary objective is to evaluate real-time gait phase estimation accuracy of the prototype controller across users; metabolic cost, biomechanics, and muscle activity are recorded as secondary measures.

A lightweight (3.5 kg) research hip exoskeleton developed at Carnegie Mellon University with powered hip flexion/extension joints, a backpack-mounted computer and battery, and thigh and waist interfaces secured with straps. An AI-driven controller estimates the user's gait state from joint angle and wearable sensor data and commands assistive hip torque in real time, limited to <0.2 Nm/kg (peak device torque 18 Nm). Participants walk on a treadmill with powered assistance, with the device worn at zero torque, and without the device. The device was determined by the UT Austin IRB to be a non-significant risk device.

Andere Namen:
  • CMU Hip Exoskeleton

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Gait Phase Estimation Error of the AI-Driven Hip Exoskeleton Controller
Zeitfenster: Day 1

Root-mean-square error (RMSE) between the controller's real-time gait phase estimate and ground-truth gait phase derived from force-instrumented treadmill data during powered hip exoskeleton walking, reported as percent of the gait cycle (%). Used to evaluate feasibility of the prototype controller across younger and older adult users.

Day 1

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Net Metabolic Power During Powered Hip Exoskeleton Walking
Zeitfenster: Day 1

Net metabolic power (W/kg), measured by open-circuit indirect calorimetry with resting value subtracted, during treadmill walking at 1.25 m/s with powered hip exoskeleton assistance.

Day 1
Peak Hip Joint Moment During Powered Hip Exoskeleton Walking
Zeitfenster: Day 1

Peak biological hip extension moment (Nm/kg), computed from motion capture and force-instrumented treadmill data, during treadmill walking with powered hip exoskeleton assistance.

Day 1
Lower-Limb Muscle Activity During Powered Hip Exoskeleton Walking
Zeitfenster: Day 1

Average electromyography (EMG) amplitude normalized to maximum voluntary contraction (%MVC), averaged across eight recorded lower-limb muscles, during treadmill walking with powered hip exoskeleton assistance.

Day 1

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Mitarbeiter

Ermittler

  • Hauptermittler: Inseung Kang, PhD, Carnegie Mellon University

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

6. August 2026

Primärer Abschluss (Geschätzt)

31. August 2027

Studienabschluss (Geschätzt)

31. Januar 2028

Studienanmeldedaten

Zuerst eingereicht

3. November 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

10. November 2026

Zuerst gepostet (Tatsächlich)

16. November 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

16. November 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

10. November 2026

Zuletzt verifiziert

1. November 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • STUDY2026_00000477
  • R21EB037268 (US NIH Stipendium/Vertrag)

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

JA

Beschreibung des IPD-Plans

De-identified individual participant data underlying published results will be shared, including biomechanics (motion capture, ground reaction forces), electromyography, metabolic, and exoskeleton sensor/controller data, along with participant characteristics (age group, sex, height, mass). Identifiable information, including video recordings, will not be shared.

IPD-Sharing-Zeitrahmen

Data will be made available no later than the time of associated publication or the end of the award period, whichever comes first, and will remain available for at least 5 years.

IPD-Sharing-Zugriffskriterien

De-identified data and supporting information will be deposited in a public data repository and made openly available to researchers without restriction, subject to the repository's terms of use.

Art der unterstützenden IPD-Freigabeinformationen

  • STUDIENPROTOKOLL
  • ANALYTIC_CODE

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Ja

Produkt, das in den USA hergestellt und aus den USA exportiert wird

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .