Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Comparison of Breast Acoustic CT and Automated Breast Ultrasound in Women With Unilateral Untreated Breast Cancer

13. November 2026 aktualisiert von: Stanford University

Comparison of the Diagnostic Accuracy of Bilateral Whole Breast Ultrasound Using QT Imaging and Invenia Automated Breast Ultrasound (ABUS) [GE Healthcare] in Women With Unilateral Untreated Current Breast Cancer.

This study addresses an unmet need to improve the diagnostic accuracy of: 1. supplemental breast cancer screening with whole breast US and 2. the evaluation of disease extent in women with newly diagnosed breast cancer.

Studienübersicht

Status

Noch keine Rekrutierung

Bedingungen

Intervention / Behandlung

Studientyp

Interventionell

Einschreibung (Geschätzt)

40

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studienorte

    • California
      • Palo Alto, California, Vereinigte Staaten, 94304
        • Stanford University
        • Kontakt:
        • Hauptermittler:
          • Steven P Poplack, MD

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre und älter (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Weiblich

Beschreibung

Inclusion Criteria:

  1. Unilateral untreated breast cancer evaluated by breast MRI
  2. Participants' age range ≥18 years old
  3. Ability to understand and the willingness to provide written informed consent.
  4. Female gender
  5. Dense Breast composition
  6. Breast MRI available for reference comparison
  7. Able to undergo QT and ABUS imaging prior to definitive surgery or neoadjuvant therapy.

Exclusion Criteria:

  1. Prior mastectomy
  2. Bilateral breast cancer
  3. Concurrent use of investigational agents
  4. Active breast infection, open wound, or skin condition involving the breast that would interfere with imaging.
  5. Breast size or body habitus incompatible with QT or ABUS image acquisition. i. Breasts with cup size A through DDD. Up to 400lbs of patient weight is supported.
  6. Non-dense breast composition
  7. Pregnant
  8. Breast feeding
  9. Receipt of neoadjuvant chemotherapy, endocrine therapy, or radiation therapy before QT/ABUS imaging

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Diagnose
  • Zuteilung: N / A
  • Interventionsmodell: Einzelgruppenzuweisung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: QTI Breast Acoustic CT™ Scanner [QT Imaging] (QT), and Automated Breast Ultrasound (ABUS)

Each participant will undergo one (1) imaging examination using the investigational QT Scanner and one (1) imaging examination using the FDA-cleared Invenia™ Automated Breast Ultrasound System (ABUS).

QT: The scanner is an FDA-cleared imaging technology that uses transmission ultrasound to generate quantitative maps of breast tissue properties (e.g., speed of sound, absorption) as well as provides reflection ultrasound images. It is a non-invasive, non-ionizing imaging modality and does not involve administration of a drug or biologic. Each participant will undergo one (1) imaging examination using the QT Scanner for comparison with images obtained using automated breast ultrasound (ABUS)

ABUS is FDA-approved for both supplemental breast cancer screening in women with radiographically dense breast tissue, and for diagnostic breast ultrasound imaging. Each participant will undergo one ABUS imaging examination for comparison with images obtained using the investigational QT Scanner.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Number of Additional Breast Cancer Lesions Detected
Zeitfenster: Baseline

The number of additional contralateral and ipsilateral breast cancer lesions detected using the QT scanner and ABUS as reported by study radiologists in women with dense breast tissue and newly diagnosed unilateral breast cancer.

Baseline
BI-RADS Assessment
Zeitfenster: Baseline

Radiologists' diagnostic assessment of contralateral and ipsilateral breast cancer lesions identified using the QT Scanner and ABUS, as measured using the Breast Imaging Reporting and Data System (BI-RADS) classification categories.

Baseline
Numerical Likelihood of Malignancy
Zeitfenster: Baseline

Radiologists will assess the likelihood of malignancy for contralateral and ipsilateral breast cancer lesions detected by QT Scanner and ABUS. Diagnostic confidence will be measured using the numerical likelihood-of-malignancy estimates assigned to identified lesions.

Baseline

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Mitarbeiter

Ermittler

  • Hauptermittler: Steven P Poplack, Stanford University

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

1. Januar 2027

Primärer Abschluss (Geschätzt)

1. Januar 2029

Studienabschluss (Geschätzt)

1. Januar 2029

Studienanmeldedaten

Zuerst eingereicht

6. November 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

13. November 2026

Zuerst gepostet (Tatsächlich)

18. November 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

18. November 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

13. November 2026

Zuletzt verifiziert

1. November 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • IRB-89405

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Ja

Produkt, das in den USA hergestellt und aus den USA exportiert wird

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .