Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

I-PRF Coating of Dental Implant Surfaces for Improving Implant Stability.

14. November 2026 aktualisiert von: Damascus University

Evaluation of Injectable Platelet-Rich Fibrin (I-PRF) Coating of Implant Surfaces for Enhancing Implant Stability Compared With Conventional Implant Placement: A Randomized Controlled Clinical Trial.

This study was a double-blind, randomized controlled clinical trial with a split-mouth design, conducted among patients attending the Department of Oral and Maxillofacial Surgery and Dental Implant Clinics at the Faculty of Dentistry, Damascus University, between 2023 and 2025. The study aimed to evaluate whether coating the surface of dental implants with injectable platelet-rich fibrin (I-PRF) before implant placement could improve implant stability compared with conventional implant placement.

In the intervention group, the implant surface was coated with I-PRF before insertion, whereas implants in the control group were placed without I-PRF coating. The study included 10 implants in each group.

Implant stability was assessed using the Implant Stability Quotient (ISQ) with the Osseo 100® device. Measurements were recorded at five time points: immediately after implant placement and at 2, 4, 6, and 12 weeks after placement

Studienübersicht

Status

Abgeschlossen

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

Dental implant treatment has become an important component of modern dental practice for the rehabilitation of patients with partial or complete tooth loss. By restoring missing teeth, dental implants can contribute substantially to oral function, aesthetics, patient comfort, and oral health-related quality of life.

The long-term success of implant-supported rehabilitation depends on the establishment and maintenance of a stable biological and mechanical relationship between the implant and the surrounding bone.

Osseointegration is a fundamental biological process underlying the clinical success of dental implants. It involves the formation of a direct structural and functional connection between the implant surface and the surrounding living bone.

The quality and rate of osseointegration are influenced by several factors, including implant design, surface characteristics, surgical technique, bone quality and quantity, and local biological conditions. Consequently, considerable research has focused on modifying implant surfaces and improving the biological environment around newly placed implants in an attempt to facilitate bone healing and enhance implant stability.

Among the approaches investigated to improve the biological response to dental implants is the use of autologous platelet concentrates. Platelet-rich fibrin (PRF) is a second-generation platelet concentrate derived from the patient's own blood. It contains platelets, leukocytes, fibrin, and various biologically active substances that may contribute to tissue repair and regeneration.

Injectable platelet-rich fibrin (I-PRF) is a liquid form of PRF that can be applied to clinical sites before polymerization. Its handling characteristics allow it to be used in various regenerative applications, including the potential modification of the biological environment surrounding dental implants.

Coating the implant with an autologous biologically active material before insertion may provide a favorable local environment during the early stages of healing. The potential biological effects of I-PRF may be particularly relevant during the initial stages of bone healing, when cellular recruitment, vascularization, extracellular matrix formation, and subsequent bone formation take place around the implant.

Despite increasing interest in platelet concentrates and biological approaches to implant surface modification, the available evidence regarding the direct application of I-PRF as a coating on dental implant surfaces remains limited.

This study was therefore designed to investigate the potential effect of I-PRF coating of dental implant surfaces on implant stability compared with conventional implant placement. Implant stability was evaluated longitudinally from immediately after implant placement through the early healing period to assess the transition from primary to secondary implant stability. The study was conducted to determine whether this biological surface-treatment approach was associated with improved development of secondary implant stability compared with conventional implant placement.

Studientyp

Interventionell

Einschreibung (Tatsächlich)

5

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

      • Damascus, Syrien, 0100
        • Department of Oral and Maxillofacial Surgery and Dental Implant Clinics, Faculty of Dentistry, Damascus University, Damascus, Syria.

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

42 Jahre bis 63 Jahre (Erwachsene)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • The same inclusion criteria were applied to both study groups. Participants were eligible for inclusion if they met all of the following criteria:

    1. Good oral health.
    2. Age ≥18 years.
    3. Willingness to participate in the study after receiving adequate information about the study procedures and providing informed consent.
    4. Requirement for at least two symmetrical dental implants in the same jaw.
    5. No need for advanced surgical procedures, including sinus lift, bone splitting, or bone grafting procedures.
    6. Adequate primary implant stability, with an insertion torque of ≥20 N·cm, allowing implant placement in a single-stage surgical procedure.

Exclusion Criteria:

  • The same exclusion criteria were applied to both study groups. Participants were excluded if they met any of the following criteria:

    1. Systemic diseases that contraindicated implant surgery, such as cardiovascular disorders or coagulation disorders.
    2. Metabolic diseases that may affect normal bone metabolism, such as hyperparathyroidism or osteoporosis.
    3. Uncontrolled diabetes mellitus.
    4. Use of medications that may adversely affect healing, bone metabolism, or osseointegration, including corticosteroids, antiresorptive medications, or chemotherapeutic agents.
    5. Previous or current radiotherapy.
    6. Pregnancy.
    7. Current smoking or alcohol or illicit drug abuse.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Doppelt

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: - The intervention group (I-PRF Group)

the surface of the dental implants (Dentis One Q®, Dentis Co., Ltd., South Korea) was coated with injectable platelet-rich fibrin (I-PRF) before insertion. (n = 10)

  • I-PRF Group: Before implant placement, 10 mL of venous blood was collected from the patient using a butterfly needle and transferred into a plain glass tube. The blood was then centrifuged at 800 rpm for 3 minutes. After centrifugation, the yellowish liquid fraction (I-PRF) was carefully aspirated from the upper layer of the tube using a 5-mL syringe. The I-PRF was then slowly applied to the entire surface of the dental implant, ensuring complete coating before insertion. The implant was subsequently placed according to the surgical protocol, with an insertion torque of 35 N·cm.
  • Conventional Group: The same type of dental implant was placed according to the standard surgical protocol, without I-PRF coating, with an insertion torque of 35 N·cm.
Kein Eingriff: - The control group: the same type of dental implants

(Dentis One Q®, Dentis Co., Ltd., South Korea) was placed without I-PRF coating. (n = 10)

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Implant Stability Quotient (ISQ)
Zeitfenster: Measurements were recorded at five time points: immediately after implant placement and at 2, 4, 6, and 12 weeks after placement.

Implant stability was assessed using the Implant Stability Quotient (ISQ) measured with the Osseo 100® device (NSK, Japan). ISQ values were recorded at five time points: immediately after implant placement (T0), and at 2 weeks (T1), 4 weeks (T2), 6 weeks (T3), and 12 weeks (T4) after implant placement.

For each implant, measurements were obtained in two perpendicular directions, and the mean of the two measurements was used for analysis. The primary outcome was the comparison of ISQ values between the I-PRF and conventional implant groups at each follow-up time point.

Measurements were recorded at five time points: immediately after implant placement and at 2, 4, 6, and 12 weeks after placement.

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Ermittler

  • Studienleiter: Eisa Wehbeh, PhD in Oral and Maxillofacial, Faculty of Dentistry, Damascus University

Publikationen und hilfreiche Links

Die Bereitstellung dieser Publikationen erfolgt freiwillig durch die für die Eingabe von Informationen über die Studie verantwortliche Person. Diese können sich auf alles beziehen, was mit dem Studium zu tun hat.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

3. Januar 2023

Primärer Abschluss (Tatsächlich)

18. Dezember 2024

Studienabschluss (Tatsächlich)

1. März 2025

Studienanmeldedaten

Zuerst eingereicht

14. November 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

14. November 2026

Zuerst gepostet (Tatsächlich)

19. November 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

19. November 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

14. November 2026

Zuletzt verifiziert

1. November 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Zusätzliche relevante MeSH-Bedingungen

Andere Studien-ID-Nummern

  • UDDS-2026-OMFS-18

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .