Outcomes From Use of a Spinal Growth Guidance System in Early Onset Scoliosis

19. November 2026 aktualisiert von: OrthoPediatrics

Post-approval Study to Evaluate the Safety and Efficacy of the VerteGlide Spinal Growth Guidance System for the Treatment of Early Onset Scoliosis (EOS)

This is a prospective, multicenter, observational study. The study will evaluate the long-term safety and performance of the VerteGlide Spinal Growth Guidance System in children with early-onset scoliosis (EOS).

All patients in the study will have blood collected during surgery to measure baseline metal ion levels. Patients will also have standardized follow-up visits. This information will help answer specific U.S. Food and Drug Administration (FDA) questions about metal exposure in the body and additional surgeries after VerteGlide treatment.

Patients will be placed into one of two groups:

Asymptomatic Post-Operative Cohort: Patients who do not have symptoms that require another surgery.

Subsequent Surgical Intervention (SSI) Cohort: Patients who have a planned or unplanned additional surgery.

During the study, some patients may move from the Asymptomatic Post-Operative Cohort to the SSI Cohort if they need another surgery.

Before any study-specific procedures are performed, informed consent will be obtained from the patient's parent or legal guardian. The patient will also provide assent when appropriate.

The study is designed to follow the usual care for children with EOS as much as possible. This will reduce extra visits and procedures for patients and their families and may help patients remain in the study.

Studienübersicht

Status

Noch keine Rekrutierung

Bedingungen

Intervention / Behandlung

Detaillierte Beschreibung

The study will evaluate 20 subjects with 25 being enrolled to account for dropouts. A subject is considered evaluable upon successful implantation of the VerteGlide System and the completed collection of the intraoperative baseline serum metal ion sample.

The VerteGlide System offers a solution for EOS patients with remaining spinal growth potential. The methodology employs a hybrid fixation strategy: fusion screws are utilized at the apex of the deformity to rigidly lock the longitudinal rods, while sliding screws are placed cephalad and caudad to the apex. This configuration stabilizes the spine while allowing for continued physiological growth along the rod axis.

The system utilizes a specialized rod design to facilitate rigid apical fixation and promote low-friction sliding at the growing segments. While the sliding pedicle screws are rigidly fixed to the vertebrae, the rod-screw interface allows for passive sliding during spinal growth, thereby minimizing the need for repetitive surgical distraction procedures until skeletal maturity.

Enrollment will primarily be accomplished by investigators screening from their patient population.

All recruitment methods must comply with federal, state, and local laws and regulations. Other possible recruitment methods include the following:

  • Referrals from outpatient clinics
  • Word of mouth
  • Patient registries and databases

Total Study Duration: Approximately 7.5 years. Enrollment Period: 24 months.

Individual Subject Follow-up Duration:

  • Subjects converted to spinal fusion: 6 months post-conversion.
  • Subjects in whom all VerteGlide components are removed and replaced by a non-fusion construct: at completion of that SSI, following collection of all SSI specimens and assessments.
  • All other subjects: including those with no SSI and those whose SSI retains, revises, supplements, or exchanges VerteGlide components, or removes all components without replacement: 60 months post-index implantation.

Subjects who are enrolled but do not meet the criteria for evaluability (e.g., failure to obtain the mandatory intraoperative baseline metal-ion sample) will be followed for safety but may be replaced to ensure that at least 20 evaluable subjects are enrolled in the study.

Study Completion: The study will conclude when all subjects have met the individual subject follow-up duration definition.

Primary Objective: To characterize the long-term safety profile of the VerteGlide system by specifically focusing on Adverse Local Tissue Reactions (ALTRs) in relation to Cobalt (Co) and Chromium (Cr) wear debris in pediatric subjects with Early Onset Scoliosis (EOS) through 60 months post-implantation or study exit.

Studientyp

Interventionell

Einschreibung (Geschätzt)

25

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Studieren Sie die Kontaktsicherung

Studienorte

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

Nicht älter als 10 Jahre (Kind)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  1. Diagnosis of EOS and will be treated with the VerteGlide system in accordance with the approved indications for use.
  2. Subject will be less than 10 years of age at the date of the index (initial) surgery.
  3. Written informed consent obtained from a legally authorized representative (and subject assent, as applicable).
  4. Subject and/or representative demonstrate an understanding of the study requirements and a willingness to comply with all scheduled follow-up procedures.

Exclusion Criteria:

  1. Documented or suspected material allergy or intolerance, specifically to Ti-6Al-4V, Titanium, and Cobalt.
  2. A metal implant (or metal component) in situ.
  3. Known inadequate bone strength for secure device fixation.
  4. Active systemic infection or infection localized to the intended implant site.
  5. Any active systemic disease (including malignancy) that, in the opinion of the Investigator, would compromise the subject's welfare or the overall integrity and outcome of the study.
  6. Inadequate soft tissue coverage over the operative site.
  7. Implant components would be too large or too small for the subject.
  8. Any patient in which implant utilization would interfere with anatomical structures or expected physiologic performance.
  9. Presence of any condition that produces loads on the device that could lead to failure (e.g., obesity).
  10. Spinal cord abnormalities that require treatment.
  11. Absent diaphragmatic function
  12. Previous spine surgery that would confound VerteGlide outcomes.
  13. Inability or unwillingness to follow a post-operative regimen or scheduled study procedures.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: N / A
  • Interventionsmodell: Einzelgruppenzuweisung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Sonstiges: Single-arm treated with VerteGlide Spinal Growth Guidance System

Patients assigned to only 1 arm - treatment with VerteGlide Spinal Growth Guidance System

Spinal Guided Growth System comprised of screws, rods and sliding segments

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Adverse Event (AE) profile and second surgery
Zeitfenster: 5 years maximum

Rate calculated through 5 years post-index procedure or 6 months post-conversion to spinal fusion.

5 years maximum

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Adverse local tissue reactions (ALTR)
Zeitfenster: 5 years maximum

Rate of ALTRs determined by histological analysis of tissue retrieved at secondary surgery

5 years maximum
Cobalt and chromium serum ion levels
Zeitfenster: 5 years maximum

Descriptive characterization of systemic cobalt and chromium levels

5 years maximum
Explant analysis
Zeitfenster: 5 years maximum

For removed hardware, evaluation includes photomicrographs, spectroscopy, and microscopy for particle size distribution

5 years maximum

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Sponsor

Ermittler

  • Studienstuhl: Scott Hoffinger, MD, OrthoPediatrics

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

31. März 2027

Primärer Abschluss (Geschätzt)

30. März 2034

Studienabschluss (Geschätzt)

30. März 2034

Studienanmeldedaten

Zuerst eingereicht

19. November 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

19. November 2026

Zuerst gepostet (Tatsächlich)

25. November 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

25. November 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

19. November 2026

Zuletzt verifiziert

1. November 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • VerteGlide 01-26

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Beschreibung des IPD-Plans

IPD may be shared with other researchers after we have met our obligations to disclose such data to FDA.

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Ja

Produkt, das in den USA hergestellt und aus den USA exportiert wird

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .