When missing tooth structure or teeth are replaced, minimal biologic risk should be involved to re-establish function and esthetics. The increased use of the adhesive technique and preservation of dental tissues have greatly impacted conservative tooth preparation design. The development use of zirconia technology and all-ceramic systems has opened the potential for fabrication inlays zirconia bridges with durability and good aesthetics.

The purpose of this study is to clinically evaluate the placement of inlay bridge made of a Y-TZP framework veneered with a pressed ceramic and bonded with a completely adhesive approach in the replacement of a single missing tooth.

Descripción general del estudio

Estado

Terminado

Condiciones

Descripción detallada

This study evaluates the use of inlay bridge made of Zirconia and all ceramic systems with three designs in the replacement process of one single tooth (i.e. a missing premolar or molar.) The first design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from e-max press.

The second design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from e-max press and the internal surface coated with glaze layer to improve the adhesion.

The third design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from e-max press and the internal surface coated with a layer of e-max ceramic press to improve the adhesion.

Tipo de estudio

Intervencionista

Inscripción (Actual)

30

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

      • Damascus, República Árabe Siria, DM20AM18
        • Department of Fixed Prosthodontics, University of Damascus Dental School, Damascus, Syria

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años a 50 años (Adulto)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  1. Good oral hygiene
  2. Low susceptibility to caries
  3. Parallel alignment of abutment teeth
  4. Immobility of the abutment teeth
  5. Minimum height of abutment teeth ≥ 5 mm (connector thickness)
  6. Maximum mesio-distal extension of the inter-dental gap of 9 mm (width of premolar) or 12 mm (width of molar)

Exclusion Criteria:

  • Severe para-functional habits.
  • Short clinical crowns (<5 mm)
  • Extensive defects of the clinical crown,
  • Loosening of teeth because of factors related to the periodontal tissues.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Triple

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Sin intervención: Zirconia and E-max Press
The first design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from E-max Press.
Experimental: Zirconia and E-max Press and Glaze
The second design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from E-max Press and the internal surface coated with a glaze layer to improve adhesion.
A coating of a glaze layer will be used at the inner surface of the bridge to improve adhesion
Experimental: Zirconia and E-max Press twice
The third design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from E-max Press and the internal surface coated with an E-max Press layer to improve adhesion.
A coating of E-max Press layer will be used at the inner surface of the bridge to improve adhesion

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Change in marginal fit
Periodo de tiempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
To examine if there is a gap between inlay margins and tooth cavity margins .It will be measured by a probe.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Change in Material Integrity
Periodo de tiempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
To examine macroscopically the presence of cracks or fractures in the veneering ceramic (retainers or pontics) or any fractures at the connectors.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Change in the Retention Status
Periodo de tiempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
The resistance of a prosthesis to displacement will be measured.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Change in Marginal Color Matching
Periodo de tiempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Examination will be done macroscopically to detect the presence of any difference in color between the margins of the tooth and inlays
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application

Otras medidas de resultado

Medida de resultado
Medida Descripción
Periodo de tiempo
Change in Sensitivity
Periodo de tiempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
The presence of any spontaneous or stimulated pain will be assumed.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Change in Patients' Satisfaction
Periodo de tiempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
A questionnaire will be used to detect the level of satisfaction regarding function and shade
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Change in Shade
Periodo de tiempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
The shade is going to be determined using Vita(R) shade guide.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Investigador principal: Mansour Abo Alkasab, DDS MSc, PhD student in Fixed Prosthodontics, University of Damascus Dental School, Damascus, Syria
  • Director de estudio: Jihad Abo Nassar, DDS MSc PhD, Associate Professor of Fixed Prosthodontics, University of Damascus Dental School, Damascus, Syria

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Publicaciones Generales

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

1 de junio de 2016

Finalización primaria (Actual)

15 de enero de 2018

Finalización del estudio (Actual)

15 de agosto de 2018

Fechas de registro del estudio

Enviado por primera vez

14 de diciembre de 2016

Primero enviado que cumplió con los criterios de control de calidad

14 de diciembre de 2016

Publicado por primera vez (Estimar)

19 de diciembre de 2016

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

11 de septiembre de 2018

Última actualización enviada que cumplió con los criterios de control de calidad

9 de septiembre de 2018

Última verificación

1 de septiembre de 2018

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • UDDS-FixPro-02-2016

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir