Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

The Clinical Performance of Inlay Zirconia Bridges

9 settembre 2018 aggiornato da: Damascus University

The Clinical Performance of Inlay Zirconia Bridges Using Three Different Designs

When missing tooth structure or teeth are replaced, minimal biologic risk should be involved to re-establish function and esthetics. The increased use of the adhesive technique and preservation of dental tissues have greatly impacted conservative tooth preparation design. The development use of zirconia technology and all-ceramic systems has opened the potential for fabrication inlays zirconia bridges with durability and good aesthetics.

The purpose of this study is to clinically evaluate the placement of inlay bridge made of a Y-TZP framework veneered with a pressed ceramic and bonded with a completely adhesive approach in the replacement of a single missing tooth.

Panoramica dello studio

Stato

Completato

Condizioni

Descrizione dettagliata

This study evaluates the use of inlay bridge made of Zirconia and all ceramic systems with three designs in the replacement process of one single tooth (i.e. a missing premolar or molar.) The first design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from e-max press.

The second design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from e-max press and the internal surface coated with glaze layer to improve the adhesion.

The third design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from e-max press and the internal surface coated with a layer of e-max ceramic press to improve the adhesion.

Tipo di studio

Interventistico

Iscrizione (Effettivo)

30

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

      • Damascus, Repubblica Araba Siriana, DM20AM18
        • Department of Fixed Prosthodontics, University of Damascus Dental School, Damascus, Syria

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 50 anni (Adulto)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  1. Good oral hygiene
  2. Low susceptibility to caries
  3. Parallel alignment of abutment teeth
  4. Immobility of the abutment teeth
  5. Minimum height of abutment teeth ≥ 5 mm (connector thickness)
  6. Maximum mesio-distal extension of the inter-dental gap of 9 mm (width of premolar) or 12 mm (width of molar)

Exclusion Criteria:

  • Severe para-functional habits.
  • Short clinical crowns (<5 mm)
  • Extensive defects of the clinical crown,
  • Loosening of teeth because of factors related to the periodontal tissues.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Triplicare

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Nessun intervento: Zirconia and E-max Press
The first design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from E-max Press.
Sperimentale: Zirconia and E-max Press and Glaze
The second design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from E-max Press and the internal surface coated with a glaze layer to improve adhesion.
A coating of a glaze layer will be used at the inner surface of the bridge to improve adhesion
Sperimentale: Zirconia and E-max Press twice
The third design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from E-max Press and the internal surface coated with an E-max Press layer to improve adhesion.
A coating of E-max Press layer will be used at the inner surface of the bridge to improve adhesion

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Change in marginal fit
Lasso di tempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
To examine if there is a gap between inlay margins and tooth cavity margins .It will be measured by a probe.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Change in Material Integrity
Lasso di tempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
To examine macroscopically the presence of cracks or fractures in the veneering ceramic (retainers or pontics) or any fractures at the connectors.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Change in the Retention Status
Lasso di tempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
The resistance of a prosthesis to displacement will be measured.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Change in Marginal Color Matching
Lasso di tempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Examination will be done macroscopically to detect the presence of any difference in color between the margins of the tooth and inlays
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application

Altre misure di risultato

Misura del risultato
Misura Descrizione
Lasso di tempo
Change in Sensitivity
Lasso di tempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
The presence of any spontaneous or stimulated pain will be assumed.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Change in Patients' Satisfaction
Lasso di tempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
A questionnaire will be used to detect the level of satisfaction regarding function and shade
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Change in Shade
Lasso di tempo: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
The shade is going to be determined using Vita(R) shade guide.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Investigatore principale: Mansour Abo Alkasab, DDS MSc, PhD student in Fixed Prosthodontics, University of Damascus Dental School, Damascus, Syria
  • Direttore dello studio: Jihad Abo Nassar, DDS MSc PhD, Associate Professor of Fixed Prosthodontics, University of Damascus Dental School, Damascus, Syria

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Pubblicazioni generali

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

1 giugno 2016

Completamento primario (Effettivo)

15 gennaio 2018

Completamento dello studio (Effettivo)

15 agosto 2018

Date di iscrizione allo studio

Primo inviato

14 dicembre 2016

Primo inviato che soddisfa i criteri di controllo qualità

14 dicembre 2016

Primo Inserito (Stima)

19 dicembre 2016

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

11 settembre 2018

Ultimo aggiornamento inviato che soddisfa i criteri QC

9 settembre 2018

Ultimo verificato

1 settembre 2018

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • UDDS-FixPro-02-2016

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Corone dentali

Prove cliniche su Glaze layer

Sottoscrivi