Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

The Clinical Performance of Inlay Zirconia Bridges

9 września 2018 zaktualizowane przez: Damascus University

The Clinical Performance of Inlay Zirconia Bridges Using Three Different Designs

When missing tooth structure or teeth are replaced, minimal biologic risk should be involved to re-establish function and esthetics. The increased use of the adhesive technique and preservation of dental tissues have greatly impacted conservative tooth preparation design. The development use of zirconia technology and all-ceramic systems has opened the potential for fabrication inlays zirconia bridges with durability and good aesthetics.

The purpose of this study is to clinically evaluate the placement of inlay bridge made of a Y-TZP framework veneered with a pressed ceramic and bonded with a completely adhesive approach in the replacement of a single missing tooth.

Przegląd badań

Status

Zakończony

Szczegółowy opis

This study evaluates the use of inlay bridge made of Zirconia and all ceramic systems with three designs in the replacement process of one single tooth (i.e. a missing premolar or molar.) The first design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from e-max press.

The second design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from e-max press and the internal surface coated with glaze layer to improve the adhesion.

The third design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from e-max press and the internal surface coated with a layer of e-max ceramic press to improve the adhesion.

Typ studiów

Interwencyjne

Zapisy (Rzeczywisty)

30

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

      • Damascus, Republika Syryjsko-Arabska, DM20AM18
        • Department of Fixed Prosthodontics, University of Damascus Dental School, Damascus, Syria

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

18 lat do 50 lat (Dorosły)

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Wszystko

Opis

Inclusion Criteria:

  1. Good oral hygiene
  2. Low susceptibility to caries
  3. Parallel alignment of abutment teeth
  4. Immobility of the abutment teeth
  5. Minimum height of abutment teeth ≥ 5 mm (connector thickness)
  6. Maximum mesio-distal extension of the inter-dental gap of 9 mm (width of premolar) or 12 mm (width of molar)

Exclusion Criteria:

  • Severe para-functional habits.
  • Short clinical crowns (<5 mm)
  • Extensive defects of the clinical crown,
  • Loosening of teeth because of factors related to the periodontal tissues.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Potroić

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Brak interwencji: Zirconia and E-max Press
The first design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from E-max Press.
Eksperymentalny: Zirconia and E-max Press and Glaze
The second design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from E-max Press and the internal surface coated with a glaze layer to improve adhesion.
A coating of a glaze layer will be used at the inner surface of the bridge to improve adhesion
Eksperymentalny: Zirconia and E-max Press twice
The third design is going to be fabricated with CAD/CAM Zirconia and the occlusal surface from E-max Press and the internal surface coated with an E-max Press layer to improve adhesion.
A coating of E-max Press layer will be used at the inner surface of the bridge to improve adhesion

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Change in marginal fit
Ramy czasowe: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
To examine if there is a gap between inlay margins and tooth cavity margins .It will be measured by a probe.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Change in Material Integrity
Ramy czasowe: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
To examine macroscopically the presence of cracks or fractures in the veneering ceramic (retainers or pontics) or any fractures at the connectors.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Change in the Retention Status
Ramy czasowe: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
The resistance of a prosthesis to displacement will be measured.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Change in Marginal Color Matching
Ramy czasowe: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Examination will be done macroscopically to detect the presence of any difference in color between the margins of the tooth and inlays
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application

Inne miary wyników

Miara wyniku
Opis środka
Ramy czasowe
Change in Sensitivity
Ramy czasowe: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
The presence of any spontaneous or stimulated pain will be assumed.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Change in Patients' Satisfaction
Ramy czasowe: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
A questionnaire will be used to detect the level of satisfaction regarding function and shade
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
Change in Shade
Ramy czasowe: Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application
The shade is going to be determined using Vita(R) shade guide.
Immediately within five minutes following cementation (T1), 3 months (T2), 6 months (T3), 12 months (T4) following application

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Śledczy

  • Główny śledczy: Mansour Abo Alkasab, DDS MSc, PhD student in Fixed Prosthodontics, University of Damascus Dental School, Damascus, Syria
  • Dyrektor Studium: Jihad Abo Nassar, DDS MSc PhD, Associate Professor of Fixed Prosthodontics, University of Damascus Dental School, Damascus, Syria

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Publikacje ogólne

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

1 czerwca 2016

Zakończenie podstawowe (Rzeczywisty)

15 stycznia 2018

Ukończenie studiów (Rzeczywisty)

15 sierpnia 2018

Daty rejestracji na studia

Pierwszy przesłany

14 grudnia 2016

Pierwszy przesłany, który spełnia kryteria kontroli jakości

14 grudnia 2016

Pierwszy wysłany (Oszacować)

19 grudnia 2016

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

11 września 2018

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

9 września 2018

Ostatnia weryfikacja

1 września 2018

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • UDDS-FixPro-02-2016

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Badania kliniczne na Korony dentystyczne

3
Subskrybuj