- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT07814391
Reconstructive Treatment of Peri-implantitis With Electrolytic Decontamination Versus Titanium Brushes (Galvo vs mech)
4 de septiembre de 2026 actualizado por: Lucrezia Paternò Holtzman, George Eastman Dental Hospital, Italy
Reconstructive Treatment of Peri-implantitis With Electrolytic Decontamination Versus Titanium Brushes: a Randomized Controlled Trial
Implants diagnosed with peri-implantitis and amenable for bone reconstructive treatment will be enrolled in the study.
The implants will randomly be treated with either an electrolytic or a mechanical cleaning of the implant surface (with titanium brushes).
In all cases, a bone graft will be used to rebuild missing bone.
Descripción general del estudio
Estado
Aún no reclutando
Condiciones
Intervención / Tratamiento
Descripción detallada
Implants diagnosed with peri-implantitis and amenable for bone reconstructive treatment will be enrolled in the study.
All implants will receive reconstructive therapy by means of a collagenated bone graft, however the method of decontamination will be randomized between electrolytic cleaning or titanium rotating brushes.
In both cases, titanium curettes will be used to remove hard deposits on the implant surface and degranulation will be completed with curettes.
Tipo de estudio
Intervencionista
Inscripción (Estimado)
38
Fase
- Fase temprana 1
Contactos y Ubicaciones
Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.
Estudio Contacto
- Nombre: Lucrezia Paterno Holtzman, DDS, MS
- Número de teléfono: +393398035371
- Correo electrónico: lucreziaph@gmail.com
Copia de seguridad de contactos de estudio
- Nombre: Luca Cordaro, DDS MD
- Correo electrónico: lucacordaro@usa.net
Criterios de participación
Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
No
Descripción
Inclusion Criteria:
- Implants with peri-implantitis (defined according to 2017 World Workshop definitions)
- contained defects with infra osseous component amenable to reconstructive treatment
- fixed and removable superstructures
- patients with no systemic conditions affecting healing (uncontrolled diabetes mellitus, chronic corticosteroid use, autoimmune conditions affecting connective tissue)
- smoking more than 10 cigarettes
Exclusion Criteria:
- mobile implants
- non removable crowns (both cement or screw retained) that cannot be removed prior to surgery
Plan de estudios
Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Único
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: Test: Electrolytic decontamination
Electrolytic decontamination with GalvoSurge (Straumann AG)
|
Electrolytic decontamination
Otros nombres:
|
|
Experimental: Control: Mechanical decontamination with rotating titanium brush
Mechanical rotating brush used with titanium curettes to remove hard tissue deposits from the implant surface
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Change in Probing pocket depth
Periodo de tiempo: from baseline to 12, 24 months post-surgery
|
distance (mm) between marginal mucosa and bottom of probable pocket
|
from baseline to 12, 24 months post-surgery
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
change in recession
Periodo de tiempo: baseline to 12 and 24 months post-op
|
change between baseline and 24 months (mm)
|
baseline to 12 and 24 months post-op
|
|
change in CAL
Periodo de tiempo: between baseline and 24 months
|
change in CAL between baseline and 24 months (mm)
|
between baseline and 24 months
|
|
Suppuration on probing (SoP)
Periodo de tiempo: baseline, 12, 24 months
|
Dichotomic variable
|
baseline, 12, 24 months
|
|
Bleeding on probing
Periodo de tiempo: baseline, 12, 24 months
|
Dichotomic variable (yes/ no)
|
baseline, 12, 24 months
|
|
Keratinized mucosa (KM)
Periodo de tiempo: baseline, 12, 24 months
|
continuous, measured in mm, from the margin of the mucosa to the mucogingival junction
|
baseline, 12, 24 months
|
|
Treatment Success
Periodo de tiempo: 24 months
|
Composite outcome comprising implant not lost, no more than 1 mm of buccal recession, no more than 5 mm of PPD, no SOP, no more than 1 bleeding spot on probing, no loss of crestal bone (mm)
|
24 months
|
Colaboradores e Investigadores
Aquí es donde encontrará personas y organizaciones involucradas en este estudio.
Patrocinador
Publicaciones y enlaces útiles
La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.
Publicaciones Generales
- Bosshardt DD, Brodbeck UR, Rathe F, Stumpf T, Imber JC, Weigl P, Schlee M. Evidence of re-osseointegration after electrolytic cleaning and regenerative therapy of peri-implantitis in humans: a case report with four implants. Clin Oral Investig. 2022 Apr;26(4):3735-3746. doi: 10.1007/s00784-021-04345-1. Epub 2022 Mar 4.
- Schlee M, Rathe F, Brodbeck U, Ratka C, Weigl P, Zipprich H. Treatment of Peri-implantitis-Electrolytic Cleaning Versus Mechanical and Electrolytic Cleaning-A Randomized Controlled Clinical Trial-Six-Month Results. J Clin Med. 2019 Nov 7;8(11):1909. doi: 10.3390/jcm8111909.
- Zipprich H, Weigl P, Di Gianfilippo R, Steigmann L, Henrich D, Wang HL, Schlee M, Ratka C. Comparison of decontamination efficacy of two electrolyte cleaning methods to diode laser, plasma, and air-abrasive devices. Clin Oral Investig. 2022 Jun;26(6):4549-4558. doi: 10.1007/s00784-022-04421-0. Epub 2022 Mar 24.
- Bernardi S, Qorri E, Botticelli G, Scarano A, Marzo G, Gatto R, Greco Lucchina A, Mortellaro C, Lupi E, Rastelli C, Falisi G. Use of electrical field for biofilm implant removal. Eur Rev Med Pharmacol Sci. 2023 Apr;27(3 Suppl):114-121. doi: 10.26355/eurrev_202304_31328.
- Zhu Y, Xu Y, Ling Z, Zhao C, Xu A, He F. The biofilm removal effect and osteogenic potential on the titanium surface by electrolytic cleaning: An in vitro comparison of electrolytic parameters and five techniques. Clin Oral Implants Res. 2024 Apr;35(4):454-466. doi: 10.1111/clr.14245. Epub 2024 Feb 12.
- Gianfreda F, Punzo A, Pistilli V, Bollero P, Cervino G, D'Amico C, Cairo F, Cicciu M. Electrolytic Cleaning and Regenerative Therapy of Peri-implantitis in the Esthetic Area: A Case Report. Eur J Dent. 2022 Oct;16(4):950-956. doi: 10.1055/s-0042-1750773. Epub 2022 Jul 4.
Fechas de registro del estudio
Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.
Fechas importantes del estudio
Inicio del estudio (Estimado)
1 de enero de 2027
Finalización primaria (Estimado)
1 de abril de 2027
Finalización del estudio (Estimado)
1 de abril de 2027
Fechas de registro del estudio
Enviado por primera vez
4 de septiembre de 2026
Primero enviado que cumplió con los criterios de control de calidad
4 de septiembre de 2026
Publicado por primera vez (Actual)
11 de septiembre de 2026
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
11 de septiembre de 2026
Última actualización enviada que cumplió con los criterios de control de calidad
4 de septiembre de 2026
Última verificación
1 de agosto de 2026
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 0801
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
SÍ
Marco de tiempo para compartir IPD
duration of study
Criterios de acceso compartido de IPD
all de-identified information
Tipo de información de apoyo para compartir IPD
- PROTOCOLO DE ESTUDIO
- SAVIA
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
No
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
No
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .