Catheter-Oriented Unloading and Recovery With a Left Ventricular Assist Gear: Efficacy in Post Cardiotomy Cardiogenic Shock (COURAGE)
Efficacy and Safety of SynFlow Duro System in the Treatment of Post Cardiotomy Cardiogenic Shock: a Prospective, Multicenter, Single-arm Clinical Trial
Tutkimuksen yleiskatsaus
Tila
Tila
Ehdot
Ehdot
Interventio / Hoito
Interventio / Hoito
Yksityiskohtainen kuvaus
Opintotyyppi
Opintotyyppi
Ilmoittautuminen (Arvioitu)
Ilmoittautuminen
Vaihe
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskeluyhteys
Opiskeluyhteys
- Nimi: Chen Jiang
- Puhelinnumero: +86 13918357410
- Sähköposti: cjiang@forqaly.com
Opiskelupaikat
-
-
Fujian
-
Fuzhou, Fujian, Kiina
- Rekrytointi
- Fujian Medical University Union Hospital
-
Ottaa yhteyttä:
- Liangwan Chen
- Sähköposti: chenliangwan@fjmu.edu.cn
-
-
Hubei
-
Wuhan, Hubei, Kiina
- Rekrytointi
- Zhongnan Hospital of Wuhan University
-
Ottaa yhteyttä:
- Jinping Liu
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Kelpoisuusvaatimukset
Opintokelpoiset iät
- Aikuinen
- Vanhempi Aikuinen
Hyväksyy terveitä vapaaehtoisia
Kuvaus
Inclusion Criteria:
- 18≤Age≤80, any sex.
- Failure to wean from CPB or refractory cardiogenic shock after cardiac surgery.
Failure to wean from CPB is defined as failed to discontinue CPB or post-weaning CI <2.2L/min/m2 + PCWP >15mmHg, despite optimal pre-weaning management and receiving at least one high dose inotrope.
Refractory cardiogenic shock is defined as a condition that occurs despite adequate fluid status and meets all the following criteria:
① CI<2.2L/min/m2 + PCWP>15mmHg despite receiving at least one high dose inotrope or IABP; OR SBP <80mmHg or MAP<50mmHg despite receiving at least one high dose intrope + high dose norepinephrine or IABP.
② Presence of at least one signs indicating hypoperfusion: decreased mentation; cold, clammy, ashen or cyanotic extremities or skin or livedo reticularis; urine output<30ml/h or 0.5ml/kg/h; or lactate>2mmol/L or metabolic acidosis.
- Patient has signed the informed consent form.
Exclusion Criteria:
- Body surface area>2.5m2.
- Presence of any cardiac assist device (other than an IABP).
- Right ventricular failure.
- Evidence of any vascular disease or anatomy precluding placement or deployment of the device (e.g. severely calcified vessel).
- Evidence of ventricular thrombus.
- Moderate or severe aortic valve insufficiency/stenosis, or severe aortic valve calcification.
- Presence of mechanical aortic valve or cardiac contractile device.
- Obstructive, hypertrophic cardiomyopathy.
- Presence of uncorrected ventricular septal defect, atrial septal defect or patent foramen ovale.
- Mechanical manifestation of AMI (e.g. ventricular septal rupture, papillary muscle rupture, ventricular rupture).
- Any hematological disorder causing fragility of blood vessel or hemolysis.
- Known allergy or intolerant to heparin.
- Presence or suspicion of active systemic infection.
- Cardiopulmonary resuscitative maneuver lasting longer than 20 minutes before device placement.
- Sustained or non-sustained ventricular tachycardia or ventricular fibrillation unresponsive to medical therapy.
- Severe hepatic dysfunction, renal failure or severe respiratory failure
- Pregnant or lactating female.
- Concomitant enrollment in another investigational drug or device study where the primary endpoint has not yet been completed or that will clinically interfere with the endpoint of this investigation.
- Other conditions considered unsuitable for participating in this investigation by the investigators.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Ei käytössä
- Inventiomalli: Yksittäinen ryhmätehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseiden lukumäärä
Aseet ja interventiot
Osallistujaryhmä / ArmOsallistujaryhmä / Arm |
Interventio / HoitoInterventio / Hoito |
|---|---|
|
Kokeellinen: SynFlow Duro
|
a novel micro-axial flow pump for temporary left ventricular assistance
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Device support success
Aikaikkuna: Up to 30 days post-explant or hospital discharge (whichever is longer)
|
Cardiac recovery (survival to 30 days post-explant or hospital discharge [which is longer] without other mechanical support including IABP) or briging to other durable cardiac therapies (heart transplantation or implantation of approved durable ventricular assist device)
|
Up to 30 days post-explant or hospital discharge (whichever is longer)
|
Toissijaiset tulostoimenpiteet
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Technical success rate
Aikaikkuna: Through device explantation, up to 14 days
|
Technical success is defined as successful device placement, deployment, startup and explantation without any device malfunction
|
Through device explantation, up to 14 days
|
|
Device support duration
Aikaikkuna: Through device explantation, up to 14 days
|
Time from device startup to device explanation
|
Through device explantation, up to 14 days
|
|
Time to recovery
Aikaikkuna: From device placement to 30 days post-explant or hospital discharge (whichever is longer)
|
Recovery is defined as survival to 30 days post-explant or hospital discharge (which is longer) without other mechanical support including IABP
|
From device placement to 30 days post-explant or hospital discharge (whichever is longer)
|
|
Major adverse event
Aikaikkuna: From device placement to 30 days post-explant or hospital discharge or bridging to other durable cardiac therapies
|
Defined as stroke or death
|
From device placement to 30 days post-explant or hospital discharge or bridging to other durable cardiac therapies
|
|
Minor adverse event
Aikaikkuna: From device placement to 30 days post-explant or hospital discharge or bridging to other durable cardiac therapies
|
Defined as minor or major bleeding, hemolysis, limb ischemia, requiring continuous renal placement therapy, ventricular tachycardia or fibrillation requiring cardioversion, sepsis, mechanical complications and major access vascular complications.
|
From device placement to 30 days post-explant or hospital discharge or bridging to other durable cardiac therapies
|
|
Adverse event
Aikaikkuna: From device placement to 30 days post-explant or hospital discharge or bridging to other durable cardiac therapies
|
Defined as untoward medical event occurring during the course of clinical investigation, whether or not related to the medical device.
|
From device placement to 30 days post-explant or hospital discharge or bridging to other durable cardiac therapies
|
|
Serious adverse event
Aikaikkuna: From device placement to 30 days post-explant or hospital discharge or bridging to other durable cardiac therapies
|
Defined as the event occurring during the course of clinical investigation, which leads to death or serious deterioration in the health, including a life-threatening illness or injury; a permanent impairment of a body structure or a body function; in-patient or prolonged hospitalization; medical or surgical intervention to prevent permanent impairment to a body structure or a body function; foetal distress, foetal death, congenital abnormality or birth defect, etc.
|
From device placement to 30 days post-explant or hospital discharge or bridging to other durable cardiac therapies
|
|
Device deficiency
Aikaikkuna: Through device explantation, up to 14 days
|
Defined as the unreasonable risk that may endanger human health and life safety in the normal use of medical devices during clinical investigations, such as labeling errors, quality problems, malfunctions, etc.
|
Through device explantation, up to 14 days
|
|
Cardiac index change versus baseline
Aikaikkuna: Within 24 hours after device startup
|
Within 24 hours after device startup
|
|
|
Cardiac output change versus baseline
Aikaikkuna: Within 24 hours after device startup
|
Within 24 hours after device startup
|
|
|
Pulmonary artery pressure change versus baseline
Aikaikkuna: Within 24 hours after device startup
|
Within 24 hours after device startup
|
|
|
Mean arterial pressure change versus baseline
Aikaikkuna: Within 24 hours after device startup
|
Within 24 hours after device startup
|
|
|
Central venous pressure change versus baseline
Aikaikkuna: Within 24 hours after device startup
|
Within 24 hours after device startup
|
Yhteistyökumppanit ja tutkijat
Sponsori
Sponsori
Tutkijat
Tutkijat
- Opintojen puheenjohtaja: Liangwan Chen, Fujian Medical University Union Hospital
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Opiskelun aloitus
Ensisijainen valmistuminen (Arvioitu)
Ensisijainen valmistuminen
Opintojen valmistuminen (Arvioitu)
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Ensimmäinen Lähetetty
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin päivitys julkaistu
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
Muut tutkimustunnusnumerot
- CSPR001
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .