Bedside Ultrasound for Confirmation of Endotracheal Tube Placement in the Emergency Department
The Role of Bedside Ultrasound in Confirming Endotracheal Tube Placement in Patients Undergoing Endotracheal Intubation in the Emergency Department
This prospective observational study evaluated the role of bedside ultrasound in confirming endotracheal tube placement in adult patients who underwent endotracheal intubation in the emergency department. Correct placement of the endotracheal tube is critical because unrecognized incorrect placement may cause hypoxemia, hypoxic brain injury, or death.
In this study, bedside ultrasound was performed during or immediately after endotracheal intubation without interfering with the intubation procedure. Ultrasound findings were compared with capnographic end-tidal carbon dioxide measurement, which was used as the reference method for confirming tube placement. The main aim was to assess whether bedside ultrasound is a useful and reliable method for confirming endotracheal tube position in emergency department patients.
Tutkimuksen yleiskatsaus
Tila
Tila
Ehdot
Ehdot
Yksityiskohtainen kuvaus
This single-center, prospective observational diagnostic accuracy study was conducted in the Emergency Department of Antalya Training and Research Hospital. Adult patients who underwent endotracheal intubation in the emergency department after ethics committee approval were included.
Endotracheal intubation was performed as part of routine emergency care by the most senior emergency medicine resident or an experienced emergency physician. Bedside ultrasound assessment was performed during or immediately after intubation by trained emergency physicians without interrupting or delaying the intubation procedure. The ultrasound examination was performed from the suprasternal notch region to assess the position of the endotracheal tube.
The physicians who performed bedside ultrasound had at least two years of emergency medicine experience and had completed accredited ultrasound training. Before study data collection, they received additional theoretical and practical training focused on ultrasound confirmation of endotracheal tube placement.
Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirmation of endotracheal tube placement. Ultrasound images were stored in the hospital computer system and reviewed by two qualified, independent radiology specialists. Images or measurements with insufficient quality were excluded from analysis. Agreement between ultrasound assessments was evaluated statistically.
The study aimed to determine whether bedside ultrasound can be used as a rapid, reliable, and practical method for confirming endotracheal tube placement in emergency department patients.
Opintotyyppi
Opintotyyppi
Ilmoittautuminen (Todellinen)
Ilmoittautuminen
Yhteystiedot ja paikat
Opiskelupaikat
-
-
konyaaltı
-
Antalya, konyaaltı, Turkki (Türkiye), 07100
- University of Health Sciences, Antalya Training and Research Hospital
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Kelpoisuusvaatimukset
Opintokelpoiset iät
- Aikuinen
- Vanhempi Aikuinen
Hyväksyy terveitä vapaaehtoisia
Näytteenottomenetelmä
Tutkimusväestö
Kuvaus
Inclusion Criteria:
- Patients aged 18 years or older
- Patients who underwent endotracheal intubation in the emergency department as part of routine emergency care
- Patients in whom bedside ultrasound and capnometric end-tidal carbon dioxide assessment were performed for confirmation of endotracheal tube placement
Exclusion Criteria:
- Patients younger than 18 years of age
- Patients with missing or incomplete study data
- Patients with ultrasound images of insufficient quality for evaluation
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
Ryhmien/kohorttien lukumäärä
Kohortit ja interventiot
Ryhmä/KohorttiRyhmä/Kohortti |
|---|
|
Patients Undergoing Endotracheal Intubation in the Emergency Department
Adult patients who underwent endotracheal intubation in the emergency department were included in this cohort.
Endotracheal intubation was performed as part of routine emergency care.
Bedside ultrasound was performed during or immediately after intubation by trained emergency physicians without interrupting the procedure.
Ultrasound findings were compared with capnometric end-tidal carbon dioxide measurement, which was used as the reference method for confirming endotracheal tube placement.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Diagnostic Accuracy of Bedside Ultrasound for Confirmation of Endotracheal Tube Placement
Aikaikkuna: During or immediately after endotracheal intubation, within a maximum of 20 seconds
|
The diagnostic accuracy of bedside ultrasound for confirming endotracheal tube placement will be evaluated by comparing ultrasound findings with capnometric end-tidal carbon dioxide measurement, which will be used as the reference method.
Diagnostic performance will be assessed using sensitivity, specificity, positive predictive value, negative predictive value, overall accuracy, and agreement with the reference method.
|
During or immediately after endotracheal intubation, within a maximum of 20 seconds
|
Yhteistyökumppanit ja tutkijat
Sponsori
Sponsori
Tutkijat
Tutkijat
- Päätutkija: MURAT DUYAN, ASSOCIATE PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
- Opintojohtaja: HALIT EKICI, MEDICAL DOCTOR, University of Health Sciences, Antalya Training and Research Hospital
- Opintojohtaja: CEMIL KAVALCI, PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
- Opintojohtaja: ENGIN DENIZ ARSLAN, ASSOCIATE PROFESSOR, University of Health Sciences, Antalya Training and Research Hospital
- Opintojohtaja: FEVZI YILMAZ, University of Health Sciences, Antalya Training and Research Hospital
Julkaisuja ja hyödyllisiä linkkejä
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Opiskelun aloitus
Ensisijainen valmistuminen (Todellinen)
Ensisijainen valmistuminen
Opintojen valmistuminen (Todellinen)
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Ensimmäinen Lähetetty
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin päivitys julkaistu
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muut tutkimustunnusnumerot
Muut tutkimustunnusnumerot
- 2025-019
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
IPD-suunnitelman kuvaus
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .