Measuring Knee Laxity and Pivot Shift in ACL-Deficient Patients
Objective Quantification of Knee Laxity Using a Robotic Knee Testing System and Correlation With Clinical Pivot Shift Grade in ACL-Deficient Patients
The goal of this observational study is to learn whether the Robotic Knee Testing system can measure knee looseness in adults with an anterior cruciate ligament, or ACL, tear.
The main question it aims to answer is whether measurements from the Robotic Knee Testing system are related to the doctor's pivot shift exam grade.
Participants will complete one study visit before ACL reconstruction. During the visit, both knees will be tested in the Robotic Knee Testing system. Researchers may also review existing medical information and imaging.
Tutkimuksen yleiskatsaus
Tila
Tila
Ehdot
Ehdot
Yksityiskohtainen kuvaus
This study includes two parts. In Phase 1, researchers will adjust the Robotic Knee Testing system settings to identify testing conditions that are safe, tolerable, and able to reproduce knee motion similar to the pivot shift exam.
During Phase 1, the device will test how knee motion changes when the leg is placed in different positions. Researchers will evaluate whether tibial internal rotation and knee flexion angle change varus-valgus knee motion. They will also evaluate whether varus-valgus knee position and knee flexion angle change internal-external tibial rotation. These tests are intended to help identify device settings that may reproduce the coupled motion seen during a clinical pivot shift exam.
The robotic torque-motion curves will also be reviewed for abrupt changes, discontinuities, or "jumps." These findings may represent the knee moving from a stable position into an unstable position.
In Phase 2, participants will be tested using the finalized device settings from Phase 1. The device will apply controlled anterior-posterior, internal-external rotation, and varus-valgus movements while measuring knee motion in six degrees of freedom. Researchers will compare the robotic measurements with the pivot shift grade documented by the treating orthopedic surgeon.
When available, existing MRI or X-ray images may also be reviewed to evaluate whether knee bone structure is related to robotic laxity measurements or pivot shift severity. No additional imaging will be performed for this study.
Opintotyyppi
Opintotyyppi
Ilmoittautuminen (Arvioitu)
Ilmoittautuminen
Yhteystiedot ja paikat
Opiskeluyhteys
Opiskeluyhteys
- Nimi: Samantha J Beckley, PhD
- Puhelinnumero: 470-955-7069
- Sähköposti: s.beckley@arthroresearch.com
Tutki yhteystietojen varmuuskopiointi
- Nimi: Shaun K Stinton, PhD
- Sähköposti: s.stinton@arthroresearch.com
Opiskelupaikat
-
-
Georgia
-
Atlanta, Georgia, Yhdysvallat, 30324
- Trailer
-
Ottaa yhteyttä:
- Samantha J Beckley, PhD
- Puhelinnumero: 470-955-7069
- Sähköposti: s.beckley@arthroresearch.com
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Kelpoisuusvaatimukset
Opintokelpoiset iät
- Aikuinen
- Vanhempi Aikuinen
Hyväksyy terveitä vapaaehtoisia
Näytteenottomenetelmä
Tutkimusväestö
Kuvaus
Inclusion Criteria:
- Adults aged 18-65 years
- Confirmed ACL tear by MRI or arthroscopic diagnosis
- Able to provide informed consent
Exclusion Criteria:
- Prior major surgery on the affected knee
- Multi-ligament knee injury
- Active infection or inflammatory arthropathy
- Inability to tolerate passive motion testing
- Pregnant or planning to become pregnant during the study period
- Unable to provide informed consent
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Clinician-graded pivot shift
Aikaikkuna: Before ACL reconstruction, during the preoperative clinical exam and/or examination under anesthesia.
|
Clinician-graded pivot shift from 0 to 3, obtained from the treating orthopedic surgeon's preoperative clinical exam and/or examination under anesthesia before ACL reconstruction.
|
Before ACL reconstruction, during the preoperative clinical exam and/or examination under anesthesia.
|
|
Association Between RKT Knee Motion Measurements and Clinician-Graded Pivot Shift Grade
Aikaikkuna: RKT testing at the preoperative study visit and pivot shift grading before ACL reconstruction
|
Relationship between Robotic Knee Testing measurements of tibiofemoral motion and clinician-graded pivot shift grade from 0 to 3. RKT measurements may include tibial translation and rotation during robotic testing.
|
RKT testing at the preoperative study visit and pivot shift grading before ACL reconstruction
|
Toissijaiset tulostoimenpiteet
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
RKT Torque-Motion Hysteresis Curve Features
Aikaikkuna: During RKT testing at the preoperative study visit before ACL reconstruction
|
Torque-displacement and torque-rotation curves from robotic testing will be evaluated for features such as slope changes, curve area, discontinuities, or "jumps" that may reflect knee instability.
|
During RKT testing at the preoperative study visit before ACL reconstruction
|
|
Effect of Knee Position on RKT Motion Measurements
Aikaikkuna: During RKT testing at the preoperative study visit before ACL reconstruction
|
RKT measurements will be compared across different testing conditions, including tibial internal rotation angle, varus-valgus knee position, knee flexion angle, and preset torque thresholds, to identify settings associated with pivot-shift-like motion.
|
During RKT testing at the preoperative study visit before ACL reconstruction
|
|
Association Between Bone Morphology and Knee Instability Measurements
Aikaikkuna: Existing imaging reviewed after enrollment and before data analysis
|
Existing MRI or X-ray images may be reviewed to assess bone morphology, including posterior tibial slope and femoral-tibial plateau geometry, and compare these measures with RKT measurements and pivot shift grade.
|
Existing imaging reviewed after enrollment and before data analysis
|
Yhteistyökumppanit ja tutkijat
Sponsori
Sponsori
Tutkijat
Tutkijat
- Päätutkija: Shaun K Stinton, PhD, Arthroresearch LLC
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Arvioitu)
Opiskelun aloitus
Ensisijainen valmistuminen (Arvioitu)
Ensisijainen valmistuminen
Opintojen valmistuminen (Arvioitu)
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Ensimmäinen Lähetetty
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin päivitys julkaistu
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
Muut tutkimustunnusnumerot
- 15940
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .