Diferences in 3D Gait Analysis After Various Types of Total Hip Arthroplasty (3DGAHIP)

maanantai 1. kesäkuuta 2026 päivittänyt: Masarykova Nemocnice v Usti nad Labem, Krajska Zdravotni a.s.

Comparative 3D Gait Analysis: Impact of Total Hip Arthroplasty Stem Anchoring (Metadiaphyseal vs Metaphyseal)

Patients with hip osteoarthritis who were indicated for total hip arthroplasty were prospectively enrolled and randomized to receive either a short (metaphyseal) stem or a conventional (metadiaphyseal) stem hip arthroplasty. Three-dimensional gait analysis was performed regularly (preoperatively and at multiple postoperative time points) to determine whether conservative implants result in superior objective and patient-reported outcomes

Tutkimuksen yleiskatsaus

Opintotyyppi

Interventio

Ilmoittautuminen (Todellinen)

20

Vaihe

  • Ei sovellettavissa

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskelupaikat

    • Ústí nad Labem Region
      • Ústí nad Labem, Ústí nad Labem Region, Tšekki, 40113
        • Masaryk Hospital

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

  • Aikuinen
  • Vanhempi Aikuinen

Hyväksyy terveitä vapaaehtoisia

Ei

Kuvaus

Inclusion Criteria:

  • high-grade hip osteoarthritis

Exclusion Criteria:

  • none

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Hoito
  • Jako: Satunnaistettu
  • Inventiomalli: Rinnakkaistehtävä
  • Naamiointi: Kaksinkertainen

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Active Comparator: Conservative (metaphyseal) stem hip arthroplasty
Hip arthroplasty is performed through a minimally invasive anterolateral hip approach. All replacements are completely non-cemented, articulations include polyethylene or ceramic inserts on ceramic heads. Cups are standardly fixed through press-fit principle, no additional pelvis screws were standardly used. Special curved femoral reamers are used in order to consume as little bone stock as possible (only the metaphysis) and provide a muscle-sparing approach.
Conservative (metaphyseal) stem Total Hip Arthroplasty
Active Comparator: Conventional (metadiaphyseal) stem hip arthroplasty
Hip arthroplasty is performed through a minimally invasive anterolateral hip approach. All replacements are completely non-cemented, articulations include polyethylene or ceramic inserts on ceramic heads. Cups are standardly fixed through press-fit principle, no additional pelvis screws were standardly used. Standard femoral preparation is performed with prosthesis taking bone stock from the metadiaphyseal area of proximal femur, however, gluteal insertions were preserved in simillar fashion as in metaphyseal implants.
Conventional (metadiaphyseal) stem Total Hip Arthroplasty

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
3D Gait analysis - Gait Profile Score
Aikaikkuna: from preoperative to 1 year postoperative
The Gait Profile Score (GPS) is a numerical index (range 0-10, the lesser the number, the better for the patient). The GPS comprises of the kinematic parameteres that are also called the Gait Variable Scores (hip flexion, rotation and abduction) and the spatiotemporal parameters (step time, step length and step cadence). All of these parameters are also mentioned ad separate outcome measures. The extraction of GPS from the 2 basic data groups was done automaticaly through specialised software which is based on the work of Baker et al. (Baker R, McGinley JL, Schwartz MH, et al. The gait profile score and movement analysis profile. Gait Posture. 2009;30(3):265-269. doi:10.1016/j.gaitpost.2009.05.020).
from preoperative to 1 year postoperative

Toissijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
The Modified Harris Hip Score
Aikaikkuna: from preoperative to 1 year postoperative
Total range of the questionnaire is 0-100 points, more points=better patient reported outcome. 90-100 points = excellent result; 80-89 = good result; 70-79 = fair result; < 70 points = poor result.
from preoperative to 1 year postoperative

Muut tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Step Time
Aikaikkuna: from preoperative to 1 year postoperative
One of the measured spatiotemporal parameters assessing the duration of a step measured in seconds. The parameter does not have a physiological normative scale.
from preoperative to 1 year postoperative
Hip flexion
Aikaikkuna: from preoperative to 1 year postoperative
One of the kinematic gait parameters = Gait Variable Scores measured in degrees. Physiological range of hip flexion is 0 to 130 degrees, the higher the range, the better for the patient.
from preoperative to 1 year postoperative
Step length
Aikaikkuna: From preoperative to 1 year postoperative
One of the measured spatiotemporal parameters assessing the length of each step measured in meters. The parameter does not have a physiological normative scale.
From preoperative to 1 year postoperative
Step cadence
Aikaikkuna: from preoperative to 1 year postoperative
One of the measured spatiotemporal parameters assessing the number of steps in a minute. The parameter does not have a physiological normative scale.
from preoperative to 1 year postoperative
Hip external rotation
Aikaikkuna: from preoperative to 1 year postoperative
One of the kinematic gait parameters = Gait Variable Scores measured in degrees. Physiological range of hip eternal rotation is 0 to 60 degrees. The higher the range, the better for the patient.
from preoperative to 1 year postoperative
Hip abduction
Aikaikkuna: From preoperative to 1 year postoperative
One of the kinematic gait parameters = Gait Variable Scores measured in degrees. Physiological range of hip abduction is 0 to 45 degress. The higher the range, the better for the patient.
From preoperative to 1 year postoperative

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Todellinen)

Maanantai 30. syyskuuta 2024

Ensisijainen valmistuminen (Todellinen)

Torstai 30. tammikuuta 2025

Opintojen valmistuminen (Todellinen)

Torstai 30. tammikuuta 2025

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Maanantai 30. maaliskuuta 2026

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Maanantai 1. kesäkuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Perjantai 5. kesäkuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Perjantai 5. kesäkuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Maanantai 1. kesäkuuta 2026

Viimeksi vahvistettu

Maanantai 1. kesäkuuta 2026

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Muut tutkimustunnusnumerot

  • 3DGAHIP

Yksittäisten osallistujien tietojen suunnitelma (IPD)

Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?

EI

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Tilaa