Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Diferences in 3D Gait Analysis After Various Types of Total Hip Arthroplasty (3DGAHIP)

Comparative 3D Gait Analysis: Impact of Total Hip Arthroplasty Stem Anchoring (Metadiaphyseal vs Metaphyseal)

Patients with hip osteoarthritis who were indicated for total hip arthroplasty were prospectively enrolled and randomized to receive either a short (metaphyseal) stem or a conventional (metadiaphyseal) stem hip arthroplasty. Three-dimensional gait analysis was performed regularly (preoperatively and at multiple postoperative time points) to determine whether conservative implants result in superior objective and patient-reported outcomes

Studieoversikt

Studietype

Intervensjonell

Registrering (Faktiske)

20

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

    • Ústí nad Labem Region
      • Ústí nad Labem, Ústí nad Labem Region, Tsjekkia, 40113
        • Masaryk Hospital

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

  • Voksen
  • Eldre voksen

Tar imot friske frivillige

Nei

Beskrivelse

Inclusion Criteria:

  • high-grade hip osteoarthritis

Exclusion Criteria:

  • none

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Behandling
  • Tildeling: Randomisert
  • Intervensjonsmodell: Parallell tildeling
  • Masking: Dobbelt

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Aktiv komparator: Conservative (metaphyseal) stem hip arthroplasty
Hip arthroplasty is performed through a minimally invasive anterolateral hip approach. All replacements are completely non-cemented, articulations include polyethylene or ceramic inserts on ceramic heads. Cups are standardly fixed through press-fit principle, no additional pelvis screws were standardly used. Special curved femoral reamers are used in order to consume as little bone stock as possible (only the metaphysis) and provide a muscle-sparing approach.
Conservative (metaphyseal) stem Total Hip Arthroplasty
Aktiv komparator: Conventional (metadiaphyseal) stem hip arthroplasty
Hip arthroplasty is performed through a minimally invasive anterolateral hip approach. All replacements are completely non-cemented, articulations include polyethylene or ceramic inserts on ceramic heads. Cups are standardly fixed through press-fit principle, no additional pelvis screws were standardly used. Standard femoral preparation is performed with prosthesis taking bone stock from the metadiaphyseal area of proximal femur, however, gluteal insertions were preserved in simillar fashion as in metaphyseal implants.
Conventional (metadiaphyseal) stem Total Hip Arthroplasty

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
3D Gait analysis - Gait Profile Score
Tidsramme: from preoperative to 1 year postoperative
The Gait Profile Score (GPS) is a numerical index (range 0-10, the lesser the number, the better for the patient). The GPS comprises of the kinematic parameteres that are also called the Gait Variable Scores (hip flexion, rotation and abduction) and the spatiotemporal parameters (step time, step length and step cadence). All of these parameters are also mentioned ad separate outcome measures. The extraction of GPS from the 2 basic data groups was done automaticaly through specialised software which is based on the work of Baker et al. (Baker R, McGinley JL, Schwartz MH, et al. The gait profile score and movement analysis profile. Gait Posture. 2009;30(3):265-269. doi:10.1016/j.gaitpost.2009.05.020).
from preoperative to 1 year postoperative

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
The Modified Harris Hip Score
Tidsramme: from preoperative to 1 year postoperative
Total range of the questionnaire is 0-100 points, more points=better patient reported outcome. 90-100 points = excellent result; 80-89 = good result; 70-79 = fair result; < 70 points = poor result.
from preoperative to 1 year postoperative

Andre resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Step Time
Tidsramme: from preoperative to 1 year postoperative
One of the measured spatiotemporal parameters assessing the duration of a step measured in seconds. The parameter does not have a physiological normative scale.
from preoperative to 1 year postoperative
Hip flexion
Tidsramme: from preoperative to 1 year postoperative
One of the kinematic gait parameters = Gait Variable Scores measured in degrees. Physiological range of hip flexion is 0 to 130 degrees, the higher the range, the better for the patient.
from preoperative to 1 year postoperative
Step length
Tidsramme: From preoperative to 1 year postoperative
One of the measured spatiotemporal parameters assessing the length of each step measured in meters. The parameter does not have a physiological normative scale.
From preoperative to 1 year postoperative
Step cadence
Tidsramme: from preoperative to 1 year postoperative
One of the measured spatiotemporal parameters assessing the number of steps in a minute. The parameter does not have a physiological normative scale.
from preoperative to 1 year postoperative
Hip external rotation
Tidsramme: from preoperative to 1 year postoperative
One of the kinematic gait parameters = Gait Variable Scores measured in degrees. Physiological range of hip eternal rotation is 0 to 60 degrees. The higher the range, the better for the patient.
from preoperative to 1 year postoperative
Hip abduction
Tidsramme: From preoperative to 1 year postoperative
One of the kinematic gait parameters = Gait Variable Scores measured in degrees. Physiological range of hip abduction is 0 to 45 degress. The higher the range, the better for the patient.
From preoperative to 1 year postoperative

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

30. september 2024

Primær fullføring (Faktiske)

30. januar 2025

Studiet fullført (Faktiske)

30. januar 2025

Datoer for studieregistrering

Først innsendt

30. mars 2026

Først innsendt som oppfylte QC-kriteriene

1. juni 2026

Først lagt ut (Faktiske)

5. juni 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

5. juni 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

1. juni 2026

Sist bekreftet

1. juni 2026

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • 3DGAHIP

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere