Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Diferences in 3D Gait Analysis After Various Types of Total Hip Arthroplasty (3DGAHIP)

Comparative 3D Gait Analysis: Impact of Total Hip Arthroplasty Stem Anchoring (Metadiaphyseal vs Metaphyseal)

Patients with hip osteoarthritis who were indicated for total hip arthroplasty were prospectively enrolled and randomized to receive either a short (metaphyseal) stem or a conventional (metadiaphyseal) stem hip arthroplasty. Three-dimensional gait analysis was performed regularly (preoperatively and at multiple postoperative time points) to determine whether conservative implants result in superior objective and patient-reported outcomes

Studie Overzicht

Studietype

Ingrijpend

Inschrijving (Werkelijk)

20

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Ústí nad Labem Region
      • Ústí nad Labem, Ústí nad Labem Region, Tsjechië, 40113
        • Masaryk Hospital

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Nee

Beschrijving

Inclusion Criteria:

  • high-grade hip osteoarthritis

Exclusion Criteria:

  • none

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Dubbele

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Actieve vergelijker: Conservative (metaphyseal) stem hip arthroplasty
Hip arthroplasty is performed through a minimally invasive anterolateral hip approach. All replacements are completely non-cemented, articulations include polyethylene or ceramic inserts on ceramic heads. Cups are standardly fixed through press-fit principle, no additional pelvis screws were standardly used. Special curved femoral reamers are used in order to consume as little bone stock as possible (only the metaphysis) and provide a muscle-sparing approach.
Conservative (metaphyseal) stem Total Hip Arthroplasty
Actieve vergelijker: Conventional (metadiaphyseal) stem hip arthroplasty
Hip arthroplasty is performed through a minimally invasive anterolateral hip approach. All replacements are completely non-cemented, articulations include polyethylene or ceramic inserts on ceramic heads. Cups are standardly fixed through press-fit principle, no additional pelvis screws were standardly used. Standard femoral preparation is performed with prosthesis taking bone stock from the metadiaphyseal area of proximal femur, however, gluteal insertions were preserved in simillar fashion as in metaphyseal implants.
Conventional (metadiaphyseal) stem Total Hip Arthroplasty

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
3D Gait analysis - Gait Profile Score
Tijdsspanne: from preoperative to 1 year postoperative
The Gait Profile Score (GPS) is a numerical index (range 0-10, the lesser the number, the better for the patient). The GPS comprises of the kinematic parameteres that are also called the Gait Variable Scores (hip flexion, rotation and abduction) and the spatiotemporal parameters (step time, step length and step cadence). All of these parameters are also mentioned ad separate outcome measures. The extraction of GPS from the 2 basic data groups was done automaticaly through specialised software which is based on the work of Baker et al. (Baker R, McGinley JL, Schwartz MH, et al. The gait profile score and movement analysis profile. Gait Posture. 2009;30(3):265-269. doi:10.1016/j.gaitpost.2009.05.020).
from preoperative to 1 year postoperative

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
The Modified Harris Hip Score
Tijdsspanne: from preoperative to 1 year postoperative
Total range of the questionnaire is 0-100 points, more points=better patient reported outcome. 90-100 points = excellent result; 80-89 = good result; 70-79 = fair result; < 70 points = poor result.
from preoperative to 1 year postoperative

Andere uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Step Time
Tijdsspanne: from preoperative to 1 year postoperative
One of the measured spatiotemporal parameters assessing the duration of a step measured in seconds. The parameter does not have a physiological normative scale.
from preoperative to 1 year postoperative
Hip flexion
Tijdsspanne: from preoperative to 1 year postoperative
One of the kinematic gait parameters = Gait Variable Scores measured in degrees. Physiological range of hip flexion is 0 to 130 degrees, the higher the range, the better for the patient.
from preoperative to 1 year postoperative
Step length
Tijdsspanne: From preoperative to 1 year postoperative
One of the measured spatiotemporal parameters assessing the length of each step measured in meters. The parameter does not have a physiological normative scale.
From preoperative to 1 year postoperative
Step cadence
Tijdsspanne: from preoperative to 1 year postoperative
One of the measured spatiotemporal parameters assessing the number of steps in a minute. The parameter does not have a physiological normative scale.
from preoperative to 1 year postoperative
Hip external rotation
Tijdsspanne: from preoperative to 1 year postoperative
One of the kinematic gait parameters = Gait Variable Scores measured in degrees. Physiological range of hip eternal rotation is 0 to 60 degrees. The higher the range, the better for the patient.
from preoperative to 1 year postoperative
Hip abduction
Tijdsspanne: From preoperative to 1 year postoperative
One of the kinematic gait parameters = Gait Variable Scores measured in degrees. Physiological range of hip abduction is 0 to 45 degress. The higher the range, the better for the patient.
From preoperative to 1 year postoperative

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

30 september 2024

Primaire voltooiing (Werkelijk)

30 januari 2025

Studie voltooiing (Werkelijk)

30 januari 2025

Studieregistratiedata

Eerst ingediend

30 maart 2026

Eerst ingediend dat voldeed aan de QC-criteria

1 juni 2026

Eerst geplaatst (Werkelijk)

5 juni 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

5 juni 2026

Laatste update ingediend die voldeed aan QC-criteria

1 juni 2026

Laatst geverifieerd

1 juni 2026

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • 3DGAHIP

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren