Prosthetic Complications in Full-arch Screw-retained Implant Restorations Using Monolithic Zirconia Versus Titanium Frameworks: A Randomized Clinical Trial

sunnuntai 14. kesäkuuta 2026 päivittänyt: Ahmad Diab Ahmad ElSayed, Cairo University
The goal of this clinical trial is to to compare the prosthetic complication rate and Oral Health-Related Quality of Life (OHRQoL) between screw-retained monolithic zirconia frameworks and CNC-milled titanium frameworks with zirconia superstructures in completely edentulous patients restored with full-arch implant-supported prostheses over a follow-up period of 12 months.

Tutkimuksen yleiskatsaus

Opintotyyppi

Interventio

Ilmoittautuminen (Arvioitu)

12

Vaihe

  • Ei sovellettavissa

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskelupaikat

      • Cairo, Egypti, 11553
        • Rekrytointi
        • Faculty of Dentistry - Cairo University
        • Ottaa yhteyttä:

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

  • Aikuinen
  • Vanhempi Aikuinen

Hyväksyy terveitä vapaaehtoisia

Ei

Kuvaus

Inclusion Criteria:

  1. Aged 18 years or older.
  2. Able to understand the study procedures and provide written informed consent.
  3. In good general health, classified as American Society of Anesthesiologists (ASA) Physical Status Class I or II.
  4. Completely edentulous in the arch to be treated (maxilla and/or mandible).
  5. A candidate for a full-arch, screw-retained implant-supported prosthesis, requiring 4 to 6 implants in the treatment arch.
  6. Sufficient bone volume at planned implant sites to place implants of at least 3.5mm in diameter and 8mm in length.
  7. Adequate crown height space (15-22 mm) for a fixed prosthesis.
  8. A zone of keratinized mucosa at the crest of the ridge measuring at least 2 mm in width.
  9. Opposing arch is fixed full-arch implant-supported prosthesis.
  10. Demonstrates acceptable oral hygiene and the motivation to maintain it.

Exclusion Criteria:

  1. Medical contraindications:

    • Uncontrolled diabetes (HbA1c > 7.0%).
    • History of radiotherapy in the head and neck region.
    • History of intravenous bisphosphonate therapy.
    • Immunosuppressed or immunocompromised status.
    • Any other uncontrolled systemic disease that constitutes a contraindication for oral surgery.
  2. Behavioral Factors:

    • Heavy smoking, defined as consumption of more than 10 cigarettes per day.
    • Presence of parafunctional habits (e.g., bruxism, clenching) as diagnosed by clinical examination.
  3. Local Oral Factors:

    • Active, untreated periodontal disease in any remaining dentition.
    • Presence of acute oral infection or pathology at the intended surgical site.
    • Crown height space less than 15 mm or more than 22 mm.
    • Insufficient keratinized mucosa (< 2 mm width) that cannot be corrected with a simple surgical procedure prior to implant placement.
  4. General:

    • Pregnancy or lactation.
    • Participation in another interventional clinical trial.
    • Perceived inability to comply with the study protocol and follow-up schedule.

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Hoito
  • Jako: Satunnaistettu
  • Inventiomalli: Rinnakkaistehtävä
  • Naamiointi: Ei mitään (avoin tarra)

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Kokeellinen: Monolithic zirconia framework
The prosthesis is a one-piece, full-arch framework milled from a single, monolithic zirconia blank. It includes the infrastructure, prosthetic teeth, and gingival contours. The prosthesis is screw-retained directly to multi-unit abutments.

Intervention: Screw-Retained Monolithic Zirconia Prosthesis

  • Components: The prosthesis is a one-piece, full-arch framework milled from a single, monolithic zirconia blank. It includes the infrastructure, prosthetic teeth, and gingival contours. The prosthesis is screw-retained directly to multi-unit abutments. The prosthesis is delivered on the day of final insertion and is intended to be a definitive, long-term restoration.
  • Procedure for Tailoring: The prosthesis is fully customized for each participant using a digital workflow:

    1. Digital Impression: An intraoral scan (Medit i700 scanner ) of the multi-unit abutment scan bodies will be performed.
    2. Prosthesis Design: The prosthesis will be digitally designed in the CAD software BlenderforDental .
    3. Fabrication: The design file will be processed in Millbox CAM software and milled from a zirconia blank using a 5-axis milling machine.
Muut nimet:
  • Screw-Retained Monolithic Zirconia Prosthesis
Active Comparator: CNC-milled titanium framework and zirconia superstructure

The prosthesis consists of two parts: A CNC-milled titanium framework, and a CNC-milled zirconia superstructure that is cemented onto the framework.

The titanium framework is screw-retained directly to multi-unit abutments. The zirconia superstructure is permanently cemented to the framework with resin cement.

The prosthesis consists of two parts: A CNC-milled titanium framework, and a CNC-milled zirconia superstructure that is cemented onto the framework. The titanium framework is screw-retained directly to multi-unit abutments. The zirconia superstructure is permanently cemented to the framework with resin cement.
Muut nimet:
  • CNC-milled titanium framework

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Prosthetic complications
Aikaikkuna: 1 year
The primary outcome of this study is the incidence of prosthetic complications over 12-month follow-up period. A prosthetic complication is defined as any mechanical or technical issue affecting the prosthesis that requires clinical intervention. This will be assessed through a standardized clinical examination conducted by a calibrated examiner. The outcome for each participant will be recorded as a binary variable (Yes/No).
1 year

Toissijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Oral Health-Related Quality of Life (OHRQoL)
Aikaikkuna: 1 year
The secondary outcome of this study is the change in Oral Health-Related Quality of Life (OHRQoL) over the 12-month follow-up period. This will be measured using the validated Arabic version of the 5-item Oral Health Impact Profile (OHIP5-Ar) questionnaire (Alhajj et al., 2019). The questionnaire consists of 5 questions, each rated on a Likert scale (e.g., 0 = Never, 1 = Hardly ever, 2 = Occasionally, 3 = Fairly often, 4 = Very often). The total score ranges from 0 to 20, with a higher score indicating a greater negative impact on OHRQoL. The change from baseline to 3, 6 and 12 months will be analyzed.
1 year

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Sponsori

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Todellinen)

Sunnuntai 12. huhtikuuta 2026

Ensisijainen valmistuminen (Arvioitu)

Lauantai 1. toukokuuta 2027

Opintojen valmistuminen (Arvioitu)

Lauantai 1. toukokuuta 2027

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Sunnuntai 14. kesäkuuta 2026

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Sunnuntai 14. kesäkuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Torstai 18. kesäkuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Torstai 18. kesäkuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Sunnuntai 14. kesäkuuta 2026

Viimeksi vahvistettu

Keskiviikko 1. huhtikuuta 2026

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Muut tutkimustunnusnumerot

  • 09062026

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Kliiniset tutkimukset Monolithic Zirconia Prosthesis

Tilaa