Mechanism Of Stent Thrombosis (MOST) Study (Most)
Mechanism Of Stent Thrombosis (MOST) Study, a Prospective Multicentre Non-randomized Registry
Aperçu de l'étude
Statut
Statut
Les conditions
Les conditions
Intervention / Traitement
Intervention / Traitement
Type d'étude
Type d'étude
Inscription (Réel)
Inscription
Phase
Phase
- Phase 4
Contacts et emplacements
Lieux d'étude
-
-
-
Florence, Italie
- Careggi Hospital, Department of Hearth and Vessels
-
-
Critères de participation
Critère d'éligibilité
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- previous PCI with bare metal stent (BMS) or drug eluting stent (DES) and a definite subacute coronary ST
- previous PCI with DES and a definite late or very late coronary ST
Exclusion Criteria:
- Development of ST within 72 hours of stent implantation (acute and early subacute ST).
- Late and very late ST of BMS.
- Absence of informed consent.
- Age less than 18 years.
- Creatinine values greater than 2.5 g/dl (this is to avoid the negative effects related to the contrast medium necessary to perform the OCT evaluation).
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Non randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Aucun (étiquette ouverte)
Nombre de bras
Armes et Interventions
Groupe de participants / BrasGroupe de participants / Bras |
Intervention / TraitementIntervention / Traitement |
|---|---|
|
Expérimental: Stent Thrombosis
Consecutive patients with stent thrombosis with stent strut assessment by OCT
|
OCT guided PCI.
Only thrombectomy in case of negative OCT findings (other than uncovered struts).
|
|
Comparateur actif: Controls
Control subjects without stent thrombosis from the RHR OCT database
|
OCT guided medical therapy.
Tailored antiplatelet therapy.
|
Que mesure l'étude ?
Principaux critères de jugement
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Percentage of uncovered stent struts
Délai: After thrombectomy
|
The percentage of uncovered stent struts by OCT in patients with subacute stent thrombosis (either DES and BMS) and the percentage of uncovered stent struts in patients with late (after one month) and very late thrombosis of DES.
|
After thrombectomy
|
Mesures de résultats secondaires
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Percentage of malapposed stent struts
Délai: After Thrombectomy
|
The percentage of malapposed stent struts by OCT in patients with subacute thrombosis of DES and BMS and the percentage of malapposed stent struts by OCT in patients with late and very late thrombosis of DES.
|
After Thrombectomy
|
|
Percentage of patients with high residual platelet reactivity
Délai: Baseline
|
The percentage of patients with residual platelet reactivity (RPR) to ADP and arachidonic acid identified by values ≥ 240 P2Y12 reaction units (PRU) and ≥ 550 aspirin reaction units (ARU), respectively,.
during aspirin and clopidogrel therapy or in which one or both the antiplatelet drugs have been interrupted.
|
Baseline
|
Collaborateurs et enquêteurs
Parrainer
Parrainer
Les enquêteurs
Les enquêteurs
- Chaise d'étude: David Antoniucci, MD, Careggi Hospital, Division of Invasive Cardiology
- Chercheur principal: Francesco Prati, MD, Rome Heart Research
Publications et liens utiles
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement primaire
Achèvement de l'étude (Réel)
Achèvement de l'étude
Dates d'inscription aux études
Première soumission
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Première publication
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour publiée
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
Autres numéros d'identification d'étude
- MOST Study
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .