Data Collection Study Using CS (CardiacSense) BP (Blood Pressure) Watch and Pillow Systems
A Data Collection Study to Collect Blood Pressure (BP) Data Using the CardiacSense BP Watch and CardiacSense Pillow Systems for Algorithm Development
Aperçu de l'étude
Statut
Statut
Les conditions
Les conditions
Intervention / Traitement
Intervention / Traitement
Description détaillée
This is a prospective single-site data collection study designed to collect blood pressure (BP) waveforms and estimate BP via the CardiacSense (CS) BP Watch and CS BP Pillow Systems, in parallel with arterial line (A-line data), auscultatory BP cuff measurements and SpO2 measurements. The data collected will be used for algorithms development of the CS BP Systems.
The study includes a screening phase followed by BP data collection session. Participants will be recruited by the Investigator according to the study eligibility criteria. Each enrolled participant will be fitted with 2 CS BP Watches (one on each hand), a CS BP Pillow, A-line and a cuff for auscultatory BP measurement.
A minimum of 100 participants who meet eligibility criteria will be enrolled in the study. After informed consent is obtained, demographic information, medical history, current medication use, Monk Skin Tone Scale, wrist and bicep circumference measurements and baseline vital signs measurements will be recorded. A modified Allen's test, a lateral difference test using non-invasive cuff auscultatory readings and additional assessments will be performed to confirm eligibility criteria.
In participants who meet the eligibility criteria, study devices (CS BP Watch and CS BP Pillow systems) will be fitted, and an A-line will be inserted into the radial artery. A dynamic response calculation will be performed to confirm the integrity of the inserted line.
After the participant has rested for at least 5 minutes, simultaneous BP recordings using both Watches, the Pillow and the A-line will begin and continue for 1 hour. During the 1-hour recording, a few dual-observer auscultatory BP cuff measurements will be performed on the arm contralateral to the A-line arm by two trained observers.
Upon completion of data collection, all devices will be removed, and adverse events will be assessed and documented.
The end of study for each participant is defined as the completion of device removal and after AE follow up by the study team. The end of the trial is defined as the completion of at least 100 valid participant datasets.
Type d'étude
Type d'étude
Inscription (Estimé)
Inscription
Phase
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
Coordonnées de l'étude
- Nom: Amarel Boss
- Numéro de téléphone: +972(54)7970016
- E-mail: amarel@cardiacsense.com
Lieux d'étude
-
-
Colorado
-
Louisville, Colorado, États-Unis, 80027
- Recrutement
- Element Boulder Avista Adventist Hospital Plaza
-
Contact:
- Breanna Moylan
- Numéro de téléphone: 303- 926-5432
- E-mail: breanna.moylan@element.com
-
Contact:
- Monica Rabanal, FNP
- Numéro de téléphone: 303- 926-5432
- E-mail: monica.rabanal@element.com
-
Chercheur principal:
- Monica Rabanal, FNP
-
-
Critères de participation
Critère d'éligibilité
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
La description
Main Inclusion Criteria:
- 50-80 years old.
- Ability and willingness to sign and understand an informed consent form.
- The participant has a palpable radial pulse in both wrists.
- The participant is willing and able to be fitted with the investigational devices, A-line, and reference cuff, and is willing and able to undergo all study procedures, including 1 hour of recording with the investigational devices and A-line.
- Participant has good signal quality with the CS Pillow at both wrists.
- Participant has good PPG signals in both thumbs.
- Participant has good ECG signals using the Watch.
Main Exclusion Criteria:
- Participant who are currently enrolled in another clinical investigation in which the intervention might compromise the safety of the participant or interfere with the data collected.
- Participant who has previously participated in a BP study conducted by CardiacSense.
- Participant whose body habitus precludes them from wearing the investigational devices.
- Female participants who self-reported as pregnant based on a urine pregnancy test, or who are self-reported as trying to get pregnant or who are breastfeeding.
- Participant whose BMI is greater than 35.
- Participant with a documented medical history of cardiac arrhythmia or if arrhythmia was detected during the screening.
- Participant with diagnosed diabetes mellitus.
- Participant with implanted cardiac defibrillators or pacemakers, Ventricular Assist Device (VAD) or other mechanical circulatory support devices, whether intracorporal or extracorporeal.
- Participant with stage 4 or stage 5 end-stage renal disease, or participants with arteriovenous shunts.
- Participant with pheochromocytoma or primary hyperaldosteronism.
- Participant with diagnosed heart failure with New York Heart Association (NYHA) class III/IV, or participants with a history of stroke.
- Participant with a known clotting disorders or currently taking a prescription anticoagulants (daily aspirin use is permitted).
- Participant with an infection requiring antibiotics.
- Participant with autonomic dysfunction (such as orthostatic hypotension or neuropathy).
- Participant with peripheral artery disease
- Participants with compromised circulation, including Raynaud's syndrome.
- Participant has a fracture, severe trauma, or anatomical deformity involving the wrist or fingers intended for placement of the investigational devices, which could interfere with proper fitting or function of the devices.
- Participant with moderate to severe valvulopathies.
- Participant with primary vasculitis.
- Participant with tremors or otherwise unable to remain still for 1 hour.
- Participants with changes to their antihypertensive medication regimen, including initiation, discontinuation, or dose modification, within 30 days prior to enrollment.
- The left to right arm lateral difference of the average systolic blood pressure values is more than 15 mmHg or the lateral difference of the average diastolic blood pressure values is more than 10 mmHg.
- Participant belongs to a recruitment category that has already been filled, including BMI category, height category, age group, sex, skin tone category, or blood pressure classification group.
- Participant with contact allergy to ultrasound gel.
- Participant with prior or known allergies to lidocaine (or similar pharmacological agents, e.g. Novocaine).
- Participant with severe contact allergies to standard adhesives, latex or other materials found in pulse oximetry sensors, ECG electrodes, respiration monitor electrodes or other medical sensors (self-reported).
- Participant with other known health conditions, that might put the participant at risk or might jeopardize the quality of the data collected.
- Participant that fails the modified Allen's test (Perfusion Index Ulnar/Ulnar+Radial Ratio test) (Ratio < 0.4).
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Autre
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Nombre de bras
Armes et Interventions
Groupe de participants / BrasGroupe de participants / Bras |
Intervention / TraitementIntervention / Traitement |
|---|---|
|
Expérimental: CS BP Watch System and CS BP Pillow System
Data collected from the CS BP Watch and Pillow Systems will be compared to data collected from Arterial Line and auscultatory BP cuff measurements
|
The CS BP Watch System is a wrist-worn data acquisition system designed to estimate BP from time-synchronized ECG and PPG signals. The CS Pillow System estimates BP using a combination of ECG and tonometry signals. The system is comprised of a tonometry-based sensor which is embedded in a biocompatible "pillow" for improved sensitivity and comfort. The Pillow is placed over the pulsatile area of the radial artery using a wristband. Data collected using the CS Watch and CS Pillow Systems will be compared to data collected using Arterial Line and auscultatory BP cuff measurements
Autres noms:
|
Que mesure l'étude ?
Principaux critères de jugement
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Number of subjects with complete protocol-defined multi-modal physiological signal acquisition
Délai: day 1, 1 hour
|
The primary outcome measure is the number of subjects with complete protocol-defined multi-modal physiological signal acquisition.
Multi-modal physiological signal acquisition includes simultaneous recording of: (i) photoplethysmography (PPG); ii) single lead electrocardiography (ECG); iii) tonometry signals from the investigational BP Pillow System ; (iv) continuous invasive arterial blood pressure signals.
|
day 1, 1 hour
|
Collaborateurs et enquêteurs
Parrainer
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Début de l'étude
Achèvement primaire (Estimé)
Achèvement primaire
Achèvement de l'étude (Estimé)
Achèvement de l'étude
Dates d'inscription aux études
Première soumission
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Première publication
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour publiée
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
Autres numéros d'identification d'étude
- 028_BP_DC_US
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .