Complex tibial plateau fractures, particularly Schatzker type V and VI fractures, are associated with substantial articular and metaphyseal injury and may present challenges in achieving satisfactory fracture reduction, stable fixation, soft-tissue preservation, and functional recovery.
The present comparative study will be conducted in the Orthopedic Department of Jinnah Hospital, Lahore. A total of 78 patients meeting the eligibility criteria will be recruited. Participants will be assigned to one of two treatment groups: Group A will undergo fixation using the hybrid Ilizarov technique, while Group B will undergo fixation using a locking plate technique.
Patients will undergo clinical and radiological assessment during follow-up. Functional outcome will be assessed using the Rasmussen Knee Functional Score. Radiographs will be obtained at regular follow-up intervals to evaluate fracture healing and union. Postoperative complications, including infection and non-union, will be documented.
The study will compare functional outcomes and fracture-healing outcomes between the two treatment techniques.
Type d'étude
Type d'étude
Inscription (Estimé)
Inscription
Phase
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
Coordonnées de l'étude
- Nom: Montiha Azeem
- Numéro de téléphone: 03479717317
- E-mail: muntahaazeem9@gmail.com
Sauvegarde des contacts de l'étude
- Nom: Sajjad Hussain
- Numéro de téléphone: 0333 4077389
- E-mail: prof.sajjadhussain@aimc.edu.pk
Lieux d'étude
-
-
Punjab Province
-
Lahore, Punjab Province, Pakistan, 54000
- Recrutement
- Jinnah Hospital Lahore
-
Contact:
- Sajjad Hussain
- Numéro de téléphone: 0333 4077389
- E-mail: muntahaazeem9@gmail.com
-
Contact:
- Montiha Azeem
- E-mail: muntahaazeem9@gmail.com
-
Chercheur principal:
- Sajjad Hussain
-
-
Critères de participation
Critère d'éligibilité
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
Accepte les volontaires sains
La description
Inclusion Criteria:
- Patients of either sex.
- Age between 25 and 50 years.
- Patients presenting within 2 weeks of sustaining the fracture.
- Patients diagnosed with complex tibial plateau fractures classified as Schatzker type V or VI.
- Patients willing to participate in the study.
- Patients providing written informed consent.
Exclusion Criteria:
- Associated ipsilateral limb fractures.
- Pathological fracture of the tibia.
- Associated major organ injuries.
- Psychiatric illness that may interfere with participation or outcome assessment.
- Refusal to provide informed consent.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Seul
Nombre de bras
Armes et Interventions
Groupe de participants / BrasGroupe de participants / Bras |
Intervention / TraitementIntervention / Traitement |
|---|---|
|
Expérimental: Hybrid Ilizarov Technique
Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and fixation using a hybrid Ilizarov external fixation technique.
Closed or minimally open reduction will be performed under C-arm fluoroscopic guidance, followed by application of a hybrid Ilizarov frame using tensioned Kirschner wires and Schanz screws.
Bone graft or bone substitute may be used when clinically indicated.
|
Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and fixation using a hybrid Ilizarov external fixation system under C-arm fluoroscopic guidance.
Closed or minimally open reduction will be performed as appropriate.
The construct will consist of a hybrid Ilizarov C-ring with appropriately tensioned Kirschner wires and Schanz screws.
Additional wires or fixation components may be used when required to achieve adequate fracture stability and alignment.
Bone graft or bone substitute may be used when clinically indicated.
|
|
Comparateur actif: Locking Plate Technique
Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and internal fixation using a locking compression plate under C-arm fluoroscopic guidance.
Appropriate medial and/or lateral plate fixation will be performed according to fracture configuration and stability.
Bone grafting may be used when clinically indicated.
|
Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and internal fixation using a locking compression plate under C-arm fluoroscopic guidance.
The appropriate surgical approach and medial and/or lateral plate configuration will be selected according to fracture morphology, comminution, and stability.
Bone graft or bone substitute may be used when clinically indicated.
Postoperative rehabilitation will include early knee range-of-motion exercises, non-weight-bearing ambulation initially, and progressive weight-bearing according to clinical and radiological fracture healing.
|
Que mesure l'étude ?
Principaux critères de jugement
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Rasmussen Knee Functional Score
Délai: 8 weeks and 16 weeks
|
Functional outcome will be assessed using the Rasmussen Knee Functional Score at the final postoperative assessment.
Scores will be categorized as excellent (27-30), good (20-26), fair (10-19), or poor (6-9).
The score will be compared between patients treated with hybrid Ilizarov fixation and those treated with locking plate fixation.
|
8 weeks and 16 weeks
|
Collaborateurs et enquêteurs
Parrainer
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Début de l'étude
Achèvement primaire (Estimé)
Achèvement primaire
Achèvement de l'étude (Estimé)
Achèvement de l'étude
Dates d'inscription aux études
Première soumission
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Première publication
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour publiée
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
Autres numéros d'identification d'étude
- ERB196/4/06-11-2025/AIMC/JHL
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .