Comparison of Functional Outcome Between Locking Plate Technique Versus Hybrid Ilizarov Technique in Patients With Schatzker Type V and VI Tibial Plateau Fractures (TPF)
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Complex tibial plateau fractures, particularly Schatzker type V and VI fractures, are associated with substantial articular and metaphyseal injury and may present challenges in achieving satisfactory fracture reduction, stable fixation, soft-tissue preservation, and functional recovery.
The present comparative study will be conducted in the Orthopedic Department of Jinnah Hospital, Lahore. A total of 78 patients meeting the eligibility criteria will be recruited. Participants will be assigned to one of two treatment groups: Group A will undergo fixation using the hybrid Ilizarov technique, while Group B will undergo fixation using a locking plate technique.
Patients will undergo clinical and radiological assessment during follow-up. Functional outcome will be assessed using the Rasmussen Knee Functional Score. Radiographs will be obtained at regular follow-up intervals to evaluate fracture healing and union. Postoperative complications, including infection and non-union, will be documented.
The study will compare functional outcomes and fracture-healing outcomes between the two treatment techniques.
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: Montiha Azeem
- Numero di telefono: 03479717317
- Email: muntahaazeem9@gmail.com
Backup dei contatti dello studio
- Nome: Sajjad Hussain
- Numero di telefono: 0333 4077389
- Email: prof.sajjadhussain@aimc.edu.pk
Luoghi di studio
-
-
Punjab Province
-
Lahore, Punjab Province, Pakistan, 54000
- Reclutamento
- Jinnah Hospital Lahore
-
Contatto:
- Sajjad Hussain
- Numero di telefono: 0333 4077389
- Email: muntahaazeem9@gmail.com
-
Contatto:
- Montiha Azeem
- Email: muntahaazeem9@gmail.com
-
Investigatore principale:
- Sajjad Hussain
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
- Adulto
Accetta volontari sani
Descrizione
Inclusion Criteria:
- Patients of either sex.
- Age between 25 and 50 years.
- Patients presenting within 2 weeks of sustaining the fracture.
- Patients diagnosed with complex tibial plateau fractures classified as Schatzker type V or VI.
- Patients willing to participate in the study.
- Patients providing written informed consent.
Exclusion Criteria:
- Associated ipsilateral limb fractures.
- Pathological fracture of the tibia.
- Associated major organ injuries.
- Psychiatric illness that may interfere with participation or outcome assessment.
- Refusal to provide informed consent.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Separare
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Hybrid Ilizarov Technique
Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and fixation using a hybrid Ilizarov external fixation technique.
Closed or minimally open reduction will be performed under C-arm fluoroscopic guidance, followed by application of a hybrid Ilizarov frame using tensioned Kirschner wires and Schanz screws.
Bone graft or bone substitute may be used when clinically indicated.
|
Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and fixation using a hybrid Ilizarov external fixation system under C-arm fluoroscopic guidance.
Closed or minimally open reduction will be performed as appropriate.
The construct will consist of a hybrid Ilizarov C-ring with appropriately tensioned Kirschner wires and Schanz screws.
Additional wires or fixation components may be used when required to achieve adequate fracture stability and alignment.
Bone graft or bone substitute may be used when clinically indicated.
|
|
Comparatore attivo: Locking Plate Technique
Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and internal fixation using a locking compression plate under C-arm fluoroscopic guidance.
Appropriate medial and/or lateral plate fixation will be performed according to fracture configuration and stability.
Bone grafting may be used when clinically indicated.
|
Patients with Schatzker type V or VI tibial plateau fractures will undergo fracture reduction and internal fixation using a locking compression plate under C-arm fluoroscopic guidance.
The appropriate surgical approach and medial and/or lateral plate configuration will be selected according to fracture morphology, comminution, and stability.
Bone graft or bone substitute may be used when clinically indicated.
Postoperative rehabilitation will include early knee range-of-motion exercises, non-weight-bearing ambulation initially, and progressive weight-bearing according to clinical and radiological fracture healing.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Rasmussen Knee Functional Score
Lasso di tempo: 8 weeks and 16 weeks
|
Functional outcome will be assessed using the Rasmussen Knee Functional Score at the final postoperative assessment.
Scores will be categorized as excellent (27-30), good (20-26), fair (10-19), or poor (6-9).
The score will be compared between patients treated with hybrid Ilizarov fixation and those treated with locking plate fixation.
|
8 weeks and 16 weeks
|
Collaboratori e investigatori
Sponsor
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- ERB196/4/06-11-2025/AIMC/JHL
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .