Echocardiographic Screening of Healthy Neonates for Measuring Pulmonary Artery Pressure
Aperçu de l'étude
Statut
Les conditions
Description détaillée
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
-
Alexandria, Egypte, 21131
- Neonatal Intensive Care Unit (NICU) of Alexandria University Maternity Hospital.
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- Gestational age: 37-42 weeks.
- Birthweight: 2500-4000 g.
Exclusion Criteria:
- Neonates more than 6 hours of age at time of enrollment.
- Perinatal asphyxia or hypoxia (1 min Apgar scoring<7 points)
- Cardiac structural abnormalities detected by echocardiography except patent foramen ovale and patent ductus arteriosus
- Other clinically detected congenital malformations such as cleft lip and palate, omphalocele, meningocele, etc.
- Maternal history of gestational hypertension, gestational diabetes, hyperthyroidism, hypothyroidism, and autoimmune disease
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Pulmonary artery pressure (PAP) assessment - Tricuspid valve regurgitation peak velocity
Délai: up to 72 hours
|
This is measured in apical 4 chamber view, with continuous wave Doppler using modified Bernoulli equation. Systolic pulmonary artery pressure is equivalent to right ventricular systolic pressure in absence of outflow obstruction. Systolic Pulmonary Artery Pressure (SPAP) = Right Ventricular Systolic Pressure = 4x TR2 + Right Atrial Pressure (RAP) (RAP= 3-5 mmHg) |
up to 72 hours
|
|
Pulmonary artery pressure (PAP) assessment - Pulmonary regurgitation peak velocity
Délai: up to 72 hours
|
This is measured in short axis parasternal view with continuous wave Doppler using this equation: Mean Pulmonary Artery Pressure MPAP= 4xPR2 + Right Ventricular Diastolic Pressure (RVdP=2-5 mmHg)
|
up to 72 hours
|
|
Pulmonary artery pressure (PAP) assessment - Transductal right-to-left flow peak velocity
Délai: up to 72 hours
|
This is measured in high short axis ductal view with continuous wave Doppler
|
up to 72 hours
|
|
Pulmonary artery pressure (PAP) assessment - Interventricular septum configuration
Délai: up to 72 hours
|
This is measured in short axis parasternal view above level of papillary muscles, left ventricle is normally O shaped, D or crescent shape indicated bowing of septum due to RV dysfunction.
|
up to 72 hours
|
|
Pulmonary artery pressure (PAP) assessment - Left ventricle systolic eccentricity index (LV-sEI)
Délai: up to 72 hours
|
This is measured in short axis parasternal view by measuring LV dimensions the parallel versus the perpendicular dimension.
The normal ratio is 1.
|
up to 72 hours
|
|
Right ventricular performance - Tricuspid annular plane systolic excursion(TAPSE)
Délai: up to 72 hours
|
This is measured using Mmode in apical 4 chamber view over lateral annulus of tricuspid valve
|
up to 72 hours
|
|
Right ventricular performance - Myocardial Performance Index (MPI)
Délai: up to 72 hours
|
This is measured by using pulsed wave doppler to measure isovolumetric ejection time + isovolumetric relaxation time/ right ventricular ejection time.
|
up to 72 hours
|
|
Right ventricular performance - E/A ratio
Délai: up to 72 hours
|
This is measured in apical 4 chamber view by pulsed wave Doppler on mitral valve.
The cut off value: 0.8- 2.
|
up to 72 hours
|
|
Left ventricular performance - Ejection fraction
Délai: up to 72 hours
|
This is measured using M-Mode in long axis parasternal view with a normal range of 55-75%
|
up to 72 hours
|
|
Left ventricular performance - E/A ratio
Délai: up to 72 hours
|
This is measured in apical 4 chamber view by pulsed wave Doppler on mitral valve.
The cut off value: 0.8- 2
|
up to 72 hours
|
|
Shunts evaluation - Patent Ductus arteriosus
Délai: up to 72 hours
|
Size will be evaluated in short axis parasternal view
|
up to 72 hours
|
|
Shunts evaluation - Patent Ductus arteriosus
Délai: up to 72 hours
|
Direction will be evaluated in short axis parasternal view using color Doppler
|
up to 72 hours
|
|
Shunts evaluation - Patent Foramen Ovale
Délai: up to 72 hours
|
Size will be evaluated in be viewed in subcostal view
|
up to 72 hours
|
|
Shunts evaluation - Patent Foramen Ovale
Délai: up to 72 hours
|
Direction will be evaluated in subcostal view using color Doppler
|
up to 72 hours
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Directeur d'études: Aly M Abdel-Mohsen, PhD, Faculty of Medicine, Alexandria University, Egypt
- Chercheur principal: Rana EO Kandil, MBBCh, Faculty of Medicine, Alexandria University, Egypt
- Directeur d'études: Mohamed A Khalifa, MBBCh, Faculty of Medicine, Alexandria University, Egypt
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 0106488
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .